CDE Detailed Report
Disease: Spinal Muscular Atrophy
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Spectroscopy (MRS)
Displaying 51 - 56 of 56
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Spectroscopy (MRS)
Displaying 51 - 56 of 56
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C02498 | Imaging scanner software version number text | ImgScannerSftwrVrsnNumTxt | Free-text field specifying the version number of the imaging scanner software | Free-text field specifying the version number of the imaging scanner software | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10938 | Imaging STEAM mixing duration | ImgSTEAMMixDur | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | Spectroscopy b Spectroscopy sequence parameters TE For STEAM TM | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C17949 | Spectroscopy water reference data acquire averages count | SpectroWaterRefDataAvgsCt | Count of averages of water reference data, if any, acquired | Count of averages of water reference data, if any, acquired | Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition If yes number of averages | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10965 | Spectroscopy post process residual water signal remove indicator | SpectroscopyPostPrResidWRemInd | Indicator whether residual water signal was removed in post processing | Indicator whether residual water signal was removed in post processing | Residual water signal removed? | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17937 | Spectroscopy geometry location indicator | SpectroGeomLocInd | Indicator related to anatomical site of voxel or slice of the scan being reported | Indicator related to anatomical site of voxel or slice of the scan being reported | Spectroscopy c Geometry i. Anatomical location of voxel or slice NA | N/A | N/A | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C02499 | Imaging pulse sequence type | ImgPulseSeqTyp | Type of imaging pulse sequence used | Type of imaging pulse sequence used | Spectroscopy a Sequences used | Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify | Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:35.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |