CDE Detailed Report

Disease: content
Subdomain Name: Imaging Diagnostics
CRF: welcome

Displaying 1 - 50 of 56
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Anatomical Reference Image TE Numeric Values

Answer should be recorded in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C17941 Spectroscopy geometry voxel slice size inferior superior value SpectroGeomSizeInfSupVal Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported Spectroscopy c Geometry ii. Voxel or slice size: inferior superior Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10952 Spectroscopy water suppression type SpectroWaterSupressMethodTyp Indicator of water suppression method used, if any, for the spectroscopy scan being reported Indicator of water suppression method used, if any, for the spectroscopy scan being reported Spectroscopy d Water suppression If yes CHESS;Other, specify CHESS;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17953 Imaging other nuclei text ImgOthNucleiTxt Text identification of unlisted nuclei in the image being reported Text identification of unlisted nuclei in the image being reported Nuclei Other Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12508 Imaging radio frequency coil function type ImgRFCoilFunctTyp The function of the radio frequency (RF) coil used The function of the RF coil used RF Coils Transmit Tx and or Receive Rx Tx;Rx;Tx/Rx Transmit;Receive;Transmit/Receive Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Anatomical Reference Image FOV Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm?).

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17942 Spectroscopy sequence parameter PRESS asymmetry TE1 value SpectroSeqParamPRESSAsymTE1Val Value, in ms, of echo time (TE) 1 for an asymmetric PRESS sequence if used in the scan being reported Value, in ms, of echo time (TE) 1 for an asymmetric PRESS sequence if used in the scan being reported Spectroscopy b Spectroscopy sequence parameters For PRESS is it symmetric or asymmetric? Asymmetric TE1 Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10953 Spectroscopy water signal suppression bandwidth value SpectroWaterSupressBandwdthVal Value, in Hz, of bandwidth of water suppression, if any, for the spectroscopy scan being reported Value, in Hz, of bandwidth of water suppression, if any, for the spectroscopy scan being reported Spectroscopy d Water suppression Water signal suppression bandwidth Numeric Values

N/A should be checked if location of voxel or slice is not applicable to the sequence used for imaging. Answer should be recorded in hertz (Hz)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C18689 Imaging anatomic site other text ImgAnatSiteOTH The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.10 2024-02-29 15:53:09.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12509 Imaging radio frequency coil category ImgRFCoilCat Type of radio frequency (RF) coil(s) category used for the body part scanned Type of RF coil(s) category used for the body part scanned RF Coils Type of coil Surface;Volume Surface;Volume Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes Duration of the imaging scan in minutes Spectroscopy b Spectroscopy sequence parameters Acquisition time Numeric Values

Answer should be recorded in minutes

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C17943 Spectroscopy geometry matrix in-plane size value SpectroGeomMatInPlaneSizeVal Value of the in-plane matrix size, if applicable for the spectroscopy scan being reported Value of the in-plane matrix size, if applicable for the spectroscopy scan being reported Spectroscopy c Geometry iii. Voxel volume or matrix size In plane Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10958 Spectroscopy spectral points count SpectroSpectralPointCt Count of the spectroscopic sequence parameter of spectral points used in the scan being reported Count of the spectroscopic sequence parameter of spectral points used in the scan being reported Spectroscopy b Spectroscopy sequence parameters Spectral points Numeric Values

Answer should be recorded in points

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

point
C18708 Imaging pulse sequence type other text ImgPulseSeqTypOTH The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used Other, specify Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 14:55:04.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12510 Imaging post-processing residual water signal filter name ImgPostprocessResidH2OFilName Name of the residual water signal removal filter, if any, used in post processing Name of the residual water signal removal filter, if any, used in post processing Post processing c. Residual water signal removed? If yes water signal removal filter used Alphanumeric

Only answered if Yes is answered for 'Residual water signal removed?'

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10566 Imaging radio frequency coil name ImgRFCoilName Name of the radio frequency (RF) coil(s) used for the body part scanned Name of the RF coil(s) used for the body part scanned RF Coils Name of Coil Alphanumeric

Specify the name of the RF coil

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C17944 Spectroscopy geometry voxel slice size left value SpectroGeomSizeLftRtVal Value, in mm, of voxel or slice left-right size for the spectroscopy scan being reported Value, in mm, of voxel or slice left-right size for the spectroscopy scan being reported Spectroscopy c Geometry ii. Voxel or slice size: left-right Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10959 Spectroscopy spectral bandwidth value SpectroSpectralBandwidthVal Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions Bandwidth Numeric Values

Answer should be recorded in Hz/Pixel

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz per pixel
C18714 Imaging radio frequency coil channel count other text ImgRFCoilChannelCtOTH The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 2.00 2022-06-29 16:40:00.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12511 Imaging post-processing raw data save indicator ImgPostprocessRawDataSaveInd Indicator of whether raw data was saved in post processing Indicator of whether raw data was saved in post processing Post processing d. Raw Data Saved Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:51:50.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10568 Imaging radio frequency coil channel count ImgRFCoilChannelCt Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of the coil channels in the radio frequency (RF) coil used for the imaging scan RF Coils Number of Channels 1;8;12 channels;16;24;32 channels;Other, specify Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17945 Spectroscopy sequence parameter PRESS asymmetry TE2 value SpectroSeqParamPRESSAsymTE2Val Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported Spectroscopy b Spectroscopy sequence parameters For PRESS is it symmetric or asymmetric? Asymmetric TE2 Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10960 Spectroscopy PRESS symmetry type SpectPRESSSymTyp Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided Spectroscopy d Water suppression Symmetric;Asymmetric Symmetric (TE = TE1 + TE2, TE1 = TE2);Asymmetric (TE1 =/= TE2) Alphanumeric

Answer should be recorded in milliseconds

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Magnetic Field Strength of Scanner Used 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12542 Imaging nuclei type ImgNucleiTyp The type as related to nuclei in the scan being reported The type as related to nuclei in the scan being reported Nuclei 1H;13C;31P;23Na;Other, specify 1H;13C;31P;23Na;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C10577 Imaging signal averages number ImgSignalAvgNum Number of signal acquisitions averaged in imaging acquisition Number of signal acquisitions averaged in imaging acquisition Spectroscopy b Spectroscopy sequence parameters Number of averages Numeric Values

Record the number of signal averages

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C17946 Spectroscopy sequence parameter repetition time duration SpectroSeqParamRepTimeDur Duration, in ms, of the repetition time (TR) as a spectroscopic sequence parameter in the scan being reported Duration, in ms, of the repetition time (TR) as a spectroscopic sequence parameter in the scan being reported Spectroscopy b Spectroscopy sequence parameters Repetition time TR Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10963 Imaging B0-susceptibility distortion correction indicator ImgB0SuscDistortCorrInd Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio B0-shift correction Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Name of the scanner manufacturer GE;Siemens;Philips;Toshiba;Other, specify GE;Siemens;Philips;Toshiba;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12543 Imaging anatomical reference sequence text ImgAntmicRefSeqTxt Text specification of the anatomical reference image sequence in the scan being reported Text specification of the anatomical reference image sequence in the scan being reported Anatomical Reference Image Sequence Alphanumeric

An example includes GE

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10682 Imaging anatomic site ImgAnatSite Anatomic site of body part or anatomy scanned in the imaging study Anatomic site of body part or anatomy scanned in the imaging study Body part scanned Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:53:09.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C17948 Scanner magnetic field other strength value ScannerMagFieldOthStrgthVal Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported, if unlisted Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported, if unlisted Magnetic Field Strength of Scanner Used Other Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Tesla
C10964 Imaging eddy current induced spectral distortion correction indicator ImgEddyCurIndSpDCoInd Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation Eddy current induced spectral distortion correction? Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18814 Spectroscopy water suppression other text SpectroWaterSupressMethodOTH The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02498 Imaging scanner software version number text ImgScannerSftwrVrsnNumTxt Free-text field specifying the version number of the imaging scanner software Free-text field specifying the version number of the imaging scanner software Name of the scanner software and its version number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12544 Imaging anatomical reference orientation value ImgAntmicRefOrientVal Value, in degrees, of the orientation of the anatomical reference image sequence in the scan being reported Value, in degrees, of the orientation of the anatomical reference image sequence in the scan being reported Anatomical Reference Image Orientation Numeric Values

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

degree
C10938 Imaging STEAM mixing duration ImgSTEAMMixDur Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported Spectroscopy b Spectroscopy sequence parameters TE For STEAM TM Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C17949 Spectroscopy water reference data acquire averages count SpectroWaterRefDataAvgsCt Count of averages of water reference data, if any, acquired Count of averages of water reference data, if any, acquired Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition If yes number of averages Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10965 Spectroscopy post process residual water signal remove indicator SpectroscopyPostPrResidWRemInd Indicator whether residual water signal was removed in post processing Indicator whether residual water signal was removed in post processing Residual water signal removed? Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used Spectroscopy a Sequences used Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C17937 Spectroscopy geometry location indicator SpectroGeomLocInd Indicator related to anatomical site of voxel or slice of the scan being reported Indicator related to anatomical site of voxel or slice of the scan being reported Spectroscopy c Geometry i. Anatomical location of voxel or slice NA N/A N/A Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10942 Imaging voxel anatomic site ImgVoxelAntmicSite The anatomic site in which the voxel is located (e.g., brain left frontal white matter) The anatomic site in which the voxel is located (e.g., brain left frontal white matter Spectroscopy: c Geometry i. Anatomical location of voxel or slice Alphanumeric

N/A should be checked if location of voxel or slice is not applicable to the sequence used for imaging

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C17950 Spectroscopy water signal suppression bandwidth indicator SpectroWaterSupressBandInd Indicator related to bandwidth of water suppression of the spectroscopy scan being reported Indicator related to bandwidth of water suppression of the spectroscopy scan being reported Spectroscopy d Water suppression Water signal suppression bandwidth NA N/A N/A Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12160 Spectroscopy water suppression indicator SpectroWaterSupressInd Indicator of whether water suppression was used for the spectroscopy scan being reported Indicator of whether water suppression was used for the spectroscopy scan being reported Spectroscopy: d Water suppression Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name of the scanner software and its version number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C17939 Scanner manufacturer other name ScannerManufNameOthName Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities Other, specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10945 Imaging voxel volume measurement ImgVoxelVolMeasr Volume of the voxel calculated by multiplying the three size measurements Volume of the voxel calculated by multiplying the three size measurements Spectroscopy c Geometry iii. Voxel volume: Numeric Values

If this element is answered, then matrix size in plane and z-direction can be left blank. Answer should be recorded in millimeters cubed (mm3)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

cubic millimeter
C17951 Spectroscopy sequence other type text SpectroscopySeqOthTypTxt Text specification of unlisted spectroscopy sequences used in the scan being reported Text specification of unlisted spectroscopy sequence types in the scan being reported Spectroscopy a Sequences used Other specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

CSV