CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Spectroscopy (MRS)
Displaying 1 - 50 of 56
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C08242 | Imaging acquisition duration | ImgAcquisitionDur | Duration of the imaging scan in minutes | Duration of the imaging scan in minutes | Spectroscopy b Spectroscopy sequence parameters Acquisition time | Numeric Values |
Answer should be recorded in minutes |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
minute | |||||||||
C17943 | Spectroscopy geometry matrix in-plane size value | SpectroGeomMatInPlaneSizeVal | Value of the in-plane matrix size, if applicable for the spectroscopy scan being reported | Value of the in-plane matrix size, if applicable for the spectroscopy scan being reported | Spectroscopy c Geometry iii. Voxel volume or matrix size In plane | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C18708 | Imaging pulse sequence type other text | ImgPulseSeqTypOTH | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-01 14:55:04.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10958 | Spectroscopy spectral points count | SpectroSpectralPointCt | Count of the spectroscopic sequence parameter of spectral points used in the scan being reported | Count of the spectroscopic sequence parameter of spectral points used in the scan being reported | Spectroscopy b Spectroscopy sequence parameters Spectral points | Numeric Values |
Answer should be recorded in points |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
point | |||||||||
C12510 | Imaging post-processing residual water signal filter name | ImgPostprocessResidH2OFilName | Name of the residual water signal removal filter, if any, used in post processing | Name of the residual water signal removal filter, if any, used in post processing | Post processing c. Residual water signal removed? If yes water signal removal filter used | Alphanumeric |
Only answered if Yes is answered for 'Residual water signal removed?' |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C10566 | Imaging radio frequency coil name | ImgRFCoilName | Name of the radio frequency (RF) coil(s) used for the body part scanned | Name of the RF coil(s) used for the body part scanned | RF Coils Name of Coil | Alphanumeric |
Specify the name of the RF coil |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C17944 | Spectroscopy geometry voxel slice size left value | SpectroGeomSizeLftRtVal | Value, in mm, of voxel or slice left-right size for the spectroscopy scan being reported | Value, in mm, of voxel or slice left-right size for the spectroscopy scan being reported | Spectroscopy c Geometry ii. Voxel or slice size: left-right | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||
C18714 | Imaging radio frequency coil channel count other text | ImgRFCoilChannelCtOTH | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-29 16:40:00.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10959 | Spectroscopy spectral bandwidth value | SpectroSpectralBandwidthVal | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Bandwidth | Numeric Values |
Answer should be recorded in Hz/Pixel |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C12511 | Imaging post-processing raw data save indicator | ImgPostprocessRawDataSaveInd | Indicator of whether raw data was saved in post processing | Indicator of whether raw data was saved in post processing | Post processing d. Raw Data Saved | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:51:50.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | RF Coils Number of Channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17945 | Spectroscopy sequence parameter PRESS asymmetry TE2 value | SpectroSeqParamPRESSAsymTE2Val | Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported | Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported | Spectroscopy b Spectroscopy sequence parameters For PRESS is it symmetric or asymmetric? Asymmetric TE2 | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-28 13:09:35.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10960 | Spectroscopy PRESS symmetry type | SpectPRESSSymTyp | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | Spectroscopy d Water suppression | Symmetric;Asymmetric | Symmetric (TE = TE1 + TE2, TE1 = TE2);Asymmetric (TE1 =/= TE2) | Alphanumeric |
Answer should be recorded in milliseconds |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02495 | Imaging scanner strength value type | ImgScannerStrgthValTyp | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Magnetic Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify | 1.5T;3.0T;4.0T;7.0T;Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:31.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C12542 | Imaging nuclei type | ImgNucleiTyp | The type as related to nuclei in the scan being reported | The type as related to nuclei in the scan being reported | Nuclei | 1H;13C;31P;23Na;Other, specify | 1H;13C;31P;23Na;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C17946 | Spectroscopy sequence parameter repetition time duration | SpectroSeqParamRepTimeDur | Duration, in ms, of the repetition time (TR) as a spectroscopic sequence parameter in the scan being reported | Duration, in ms, of the repetition time (TR) as a spectroscopic sequence parameter in the scan being reported | Spectroscopy b Spectroscopy sequence parameters Repetition time TR | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C10577 | Imaging signal averages number | ImgSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition | Number of signal acquisitions averaged in imaging acquisition | Spectroscopy b Spectroscopy sequence parameters Number of averages | Numeric Values |
Record the number of signal averages |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18718 | Imaging scanner strength value type other text | ImgScannerStrgthValTypOTH | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 2.10 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10963 | Imaging B0-susceptibility distortion correction indicator | ImgB0SuscDistortCorrInd | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio | B0-shift correction | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02496 | Imaging scanner manufacturer name | ImgScannerManufName | Name of manufacturer of imaging scanner | Name of manufacturer of imaging scanner | Name of the scanner manufacturer | GE;Siemens;Philips;Toshiba;Other, specify | GE;Siemens;Philips;Toshiba;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C12543 | Imaging anatomical reference sequence text | ImgAntmicRefSeqTxt | Text specification of the anatomical reference image sequence in the scan being reported | Text specification of the anatomical reference image sequence in the scan being reported | Anatomical Reference Image Sequence | Alphanumeric |
An example includes GE |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C17948 | Scanner magnetic field other strength value | ScannerMagFieldOthStrgthVal | Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported, if unlisted | Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported, if unlisted | Magnetic Field Strength of Scanner Used Other | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Tesla | ||||||||||
C10682 | Imaging anatomic site | ImgAnatSite | Anatomic site of body part or anatomy scanned in the imaging study | Anatomic site of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:09.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18814 | Spectroscopy water suppression other text | SpectroWaterSupressMethodOTH | The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported | The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10964 | Imaging eddy current induced spectral distortion correction indicator | ImgEddyCurIndSpDCoInd | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation | Eddy current induced spectral distortion correction? | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02498 | Imaging scanner software version number text | ImgScannerSftwrVrsnNumTxt | Free-text field specifying the version number of the imaging scanner software | Free-text field specifying the version number of the imaging scanner software | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C12544 | Imaging anatomical reference orientation value | ImgAntmicRefOrientVal | Value, in degrees, of the orientation of the anatomical reference image sequence in the scan being reported | Value, in degrees, of the orientation of the anatomical reference image sequence in the scan being reported | Anatomical Reference Image Orientation | Numeric Values |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
degree | |||||||||
C17949 | Spectroscopy water reference data acquire averages count | SpectroWaterRefDataAvgsCt | Count of averages of water reference data, if any, acquired | Count of averages of water reference data, if any, acquired | Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition If yes number of averages | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10938 | Imaging STEAM mixing duration | ImgSTEAMMixDur | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | Spectroscopy b Spectroscopy sequence parameters TE For STEAM TM | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C10965 | Spectroscopy post process residual water signal remove indicator | SpectroscopyPostPrResidWRemInd | Indicator whether residual water signal was removed in post processing | Indicator whether residual water signal was removed in post processing | Residual water signal removed? | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02499 | Imaging pulse sequence type | ImgPulseSeqTyp | Type of imaging pulse sequence used | Type of imaging pulse sequence used | Spectroscopy a Sequences used | Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify | Unlocalized spectroscopy;Spectroscopic imaging 2D;PRESS;Single voxel spectroscopy (SVS);Spectroscopic imaging 3D;STEAM;Multivoxel spectroscopy;ISIS;Spin echo;Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:35.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C17937 | Spectroscopy geometry location indicator | SpectroGeomLocInd | Indicator related to anatomical site of voxel or slice of the scan being reported | Indicator related to anatomical site of voxel or slice of the scan being reported | Spectroscopy c Geometry i. Anatomical location of voxel or slice NA | N/A | N/A | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C17950 | Spectroscopy water signal suppression bandwidth indicator | SpectroWaterSupressBandInd | Indicator related to bandwidth of water suppression of the spectroscopy scan being reported | Indicator related to bandwidth of water suppression of the spectroscopy scan being reported | Spectroscopy d Water suppression Water signal suppression bandwidth NA | N/A | N/A | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C10942 | Imaging voxel anatomic site | ImgVoxelAntmicSite | The anatomic site in which the voxel is located (e.g., brain left frontal white matter) | The anatomic site in which the voxel is located (e.g., brain left frontal white matter | Spectroscopy: c Geometry i. Anatomical location of voxel or slice | Alphanumeric |
N/A should be checked if location of voxel or slice is not applicable to the sequence used for imaging |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C12160 | Spectroscopy water suppression indicator | SpectroWaterSupressInd | Indicator of whether water suppression was used for the spectroscopy scan being reported | Indicator of whether water suppression was used for the spectroscopy scan being reported | Spectroscopy: d Water suppression | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C17939 | Scanner manufacturer other name | ScannerManufNameOthName | Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities | Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities | Other, specify | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C17951 | Spectroscopy sequence other type text | SpectroscopySeqOthTypTxt | Text specification of unlisted spectroscopy sequences used in the scan being reported | Text specification of unlisted spectroscopy sequence types in the scan being reported | Spectroscopy a Sequences used Other specify | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C10945 | Imaging voxel volume measurement | ImgVoxelVolMeasr | Volume of the voxel calculated by multiplying the three size measurements | Volume of the voxel calculated by multiplying the three size measurements | Spectroscopy c Geometry iii. Voxel volume: | Numeric Values |
If this element is answered, then matrix size in plane and z-direction can be left blank. Answer should be recorded in millimeters cubed (mm3) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
cubic millimeter | |||||||||
C12163 | Spectroscopy water reference data acquire indicator | SpectroWaterRefDataAcqInd | Indicator whether water reference data was acquired in addition to water suppression acquisition data | Indicator whether water reference data was acquired in addition to water suppression acquisition data | Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Anatomical Reference Image TR | Numeric Values |
Answer should be recorded inmilliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C17940 | Spectroscopy geometry voxel slice size anterior posterior value | SpectroGeomSizeAntPostVal | Value, in mm, of voxel or slice anterior-posterior size for the spectroscopy scan being reported | Value, in mm, of voxel or slice anterior-posterior size for the spectroscopy scan being reported | Spectroscopy c Geometry ii. Voxel or slice size anterior posterior | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||
C17952 | Spectroscopy sequence parameter echo time duration | SpectroSeqParamEchoTimeDur | Duration, in ms, of the echo time (TE) as a spectroscopic sequence parameter in the scan being reported | Duration, in ms, of the echo time (TE) as a spectroscopic sequence parameter in the scan being reported | Spectroscopy b Spectroscopy sequence parameters TE | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C10948 | Imaging field of view axis 3 measurement | ImgFieldViewAxis3Measr | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | z-direction (3D) | Numeric Values |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C12165 | Imaging water suppression sequence differences result text | ImgWaterSupressSeqDiffResltTxt | Text description of any differences in sequence parameters between water reference data and water suppression data | Text description of any differences in sequence parameters between water reference data and water suppression data | Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition Note any differences in sequence parameters from water suppressed | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Anatomical Reference Image TE | Numeric Values |
Answer should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.20 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C17941 | Spectroscopy geometry voxel slice size inferior superior value | SpectroGeomSizeInfSupVal | Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported | Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported | Spectroscopy c Geometry ii. Voxel or slice size: inferior superior | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||
C17953 | Imaging other nuclei text | ImgOthNucleiTxt | Text identification of unlisted nuclei in the image being reported | Text identification of unlisted nuclei in the image being reported | Nuclei Other | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C10952 | Spectroscopy water suppression type | SpectroWaterSupressMethodTyp | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Spectroscopy d Water suppression If yes | CHESS;Other, specify | CHESS;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |