CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: welcome
Displaying 1 - 50 of 57
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C18714 | Imaging radio frequency coil channel count other text | ImgRFCoilChannelCtOTH | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-29 16:40:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10588 | Imaging echo train length measurement | ImgEchoTrainLngthMeasr | Measurement of the echo train length used in imaging acquisition | Measurement of the echo train length used in imaging acquisition | DTI sequence parameters, Echo spacing, Echo train length | Numeric Values |
EPI factor |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10687 | Imaging diffusion first b value | ImgDiffusionFirstBVal | Value, in square millimeters per second, of the first b-value used in diffusion acquisition | Value, in square millimeters per second, of the first b-value used in diffusion acquisitio | DTI sequence parameters, first b-value | Numeric Values |
Answer should be recorded in mm2/s |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C17811 | Imaging phase partial Fourier value | ImgPhasPartialFourierVal | Value of the phase partial Fourier ratio, if used in imaging acquisition | Value of the phase partial Fourier ratio, if used in imaging acquisition | Partial Fourier | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C08245 | Imaging slice count | ImgSliceCt | Count representing the total number of single image planes captured during imaging acquisition | Count representing the total number of single image planes captured during imaging acquisition | DTI sequence parameters, Number of slices | Numeric Values |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18715 | Imaging radio frequency coil other text | ImgRFCoilOTH | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | Other, specify | Alphanumeric |
Check all that apply. |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10589 | Imaging shot count | ImgShotCt | The number of shots used in the imaging echo-planner acquisition | The number of shots used in the imaging echo-planner acquisition | DTI sequence parameters, Echo spacing, No. of shots: | Numeric Values |
Must be answered with Echo Spacing and Echo Train Length |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10691 | Imaging spatially registered template indicator | ImgSptllyRegistrTmpltInd | Indicator as to whether or not imaging is spatially registered to a template for data analysis | Indicator as to whether or not imaging is spatially registered to a template for data analysi | Spatially registered to a template for data analysis | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02495 | Imaging scanner strength value type | ImgScannerStrgthValTyp | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Magnetic Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify | 1.5T;3.0T;4.0T;7.0T;Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:31.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17925 | Imaging contrast agent dose | ImgContrastAgentDose | Dosage of the contrast agent used | Dosage of the contrast agent used | Contrast Used: If Yes, dosage | Numeric Values | No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:39.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10567 | Imaging radio frequency coil type | ImgRFCoilTyp | Type of radio frequency (RF) coil(s) used for the body part scanned | Type of radio frequency (RF) coil(s) used for the body part scanned | RF Receiver coil(s) and number of channels | Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify | Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify | Alphanumeric |
Check all that apply. |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:34.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-28 13:09:35.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10590 | Imaging interpolation indicator | ImgInterpolationInd | Whether the k-space data were interpolated before applying Fourier transform | Whether the k-space data were interpolated before applying Fourier transfor | DTI sequence parameters, Interpolation | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10842 | Imaging analysis software name | ImgAnlysisSftwrName | Name of the software used for data processing or analysis of the imaging study | Name of the software used for data processing or analysis of the imaging stud | Software used | Scanner provided;FSL;DtiStudio;Other, specify | Scanner provided;FSL;DtiStudio;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C02496 | Imaging scanner manufacturer name | ImgScannerManufName | Name of manufacturer of imaging scanner | Name of manufacturer of imaging scanner | Name of the scanner manufacturer | GE;Siemens;Philips;Toshiba;Other, specify | GE;Siemens;Philips;Toshiba;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18610 | Imaging in plane resolution axis 2 measurement | ImgInPlaneRsltnAxis2Measr | Axis 2 of in-plane spatial resolution used in imaging acquisition | Axis 2 of in-plane spatial resolution used in imaging acquisition | In-plane resolution | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18718 | Imaging scanner strength value type other text | ImgScannerStrgthValTypOTH | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 2.10 | 2024-03-18 15:21:17.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10591 | Imaging phase encode direction text | ImgPhasEncdeDirctTxt | Text description of the phase encode direction used in imaging technique acquisition | Text description of the phase encode direction used in imaging technique acquisition | Phase-encode direction | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10963 | Imaging B0-susceptibility distortion correction indicator | ImgB0SuscDistortCorrInd | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio | DWI co-registered to T2 image for B0-susceptibility distortion correction | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02498 | Imaging scanner software version number text | ImgScannerSftwrVrsnNumTxt | Free-text field specifying the version number of the imaging scanner software | Free-text field specifying the version number of the imaging scanner software | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C18611 | Imaging field of view axis 2 measurement | ImgFieldViewAxis2Measr | Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Field of view | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator of whether an imaging contrast agent was used for the scan | Indicator as to whether or not an imaging contrast agent was used for the scan | Contrast Used | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric |
Choose one. If yes, record the name of the contrast agent and its dosage. |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18719 | Imaging slice orientation type other text | ImgSliceOrientTypOTH | The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition | The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-01 15:08:41.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10592 | Imaging flow compensation indicator | ImgFlowCompnsatnInd | Indicator of whether flow compensation was used in imaging acquisition | Indicator of whether flow compensation was used in imaging acquisition | Flow compensation | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10964 | Imaging eddy current induced spectral distortion correction indicator | ImgEddyCurIndSpDCoInd | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation | DWI co-registered to b=0 image and corrected for subject motion and eddy current induced distortion (affine transformation) | Yes;No | Yes;No | Alphanumeric |
Affine transformation |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02499 | Imaging pulse sequence type | ImgPulseSeqTyp | Type of imaging pulse sequence used | Type of imaging pulse sequence used | DTI sequence parameters, Sequence: | Spin echo;STEAM;Other, specify | Spin echo;STEAM;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:35.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18656 | Imaging diffusion fifth b value | ImgDiffusionFifthBVal | Value, in square millimeters per second, of the fifth b-value used in diffusion acquisition | Value, in square millimeters per second, of the fifth b-value used in diffusion acquisitio | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2014-01-08 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | ||||||||||||
C10576 | Imaging in plane resolution axis 1 measurement | ImgInPlaneRsltnAxis1Measr | Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition | Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition | DTI sequence parameters, In-plane resolution | Numeric Values |
Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter | |||||||||
C10593 | Imaging fat signal suppressed indicator | ImgFatSignalSuppressedInd | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Fat signal suppressed | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C15572 | Imaging diffusion direction count | ImgDiffusionDirCt | Count of diffusion directions in the associated diffusion imaging study | Count of diffusion directions in the associated diffusion imaging study | DTI sequence parameters, Number of diffusion-weighting gradient directions | Numeric Values |
Record the number of diffusion-weighting gradient directions |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-16 14:01:43.01 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name of the scanner software | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C18657 | Imaging diffusion sixth b value | ImgDiffusionSixthBVal | Value, in square millimeters per second, of the sixth b-value used in diffusion acquisition | Value, in square millimeters per second, of the sixth b-value used in diffusion acquisitio | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2014-01-08 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | ||||||||||||
C10577 | Imaging signal averages number | ImgSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition | Number of signal acquisitions averaged in imaging acquisition | DTI sequence parameters, Number of signal averages | Numeric Values |
Record the number of signal averages |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10594 | Imaging parallel acquisition used indicator | ImgParallelAcquistionUsedInd | Indicator of whether a parallel acquisition method is used in imaging acquisition | Indicator of whether a parallel acquisition method is used in imaging acquisition | Parallel acquisition used | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17793 | Imaging diffusion fourth b value | ImgDiffusionFourthBVal | Value, in square millimeters per second, of the fourth b-value used in diffusion acquisition | Value, in square millimeters per second, of the fourth b-value used in diffusion acquisitio | DTI sequence parameters, fourth b-value | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | DTI sequence parameters, Repetition time | Numeric Values |
TR |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C18689 | Imaging anatomic site other text | ImgAnatSiteOTH | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.10 | 2024-02-29 15:53:09.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10583 | Imaging base resolution value | ImgBaseResolutionVal | Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI) | Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI | DTI sequence parameters, Base resolution | Numeric Values |
Answer should be recorded in points |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
point | |||||||||
C10595 | Imaging parallel acquisition used type | ImgParallelAcquistionMethodTyp | Type of the parallel acquisition method used in imaging acquisition | Type of the parallel acquisition method used in imaging acquisitio | If yes, method used | GRAPPA;SENSE;Other, specify | Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA);Sensitivity Encoding SENSE;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17794 | Imaging diffusion second b value | ImgDiffusionSecondBVal | Value, in square millimeters per second, of the second b-value used in diffusion acquisition | Value, in square millimeters per second, of the second b-value used in diffusion acquisitio | DTI sequence parameters, second b-value | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | DTI sequence parameters, Echo time | Numeric Values |
TE |
No references available | Adult;Pediatric | Supplemental | 3.20 | 2024-03-18 15:21:17.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C18690 | Imaging analysis software other text | ImgAnlysisSftwrOTH | The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging study | The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging stud | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10584 | Imaging phase resolution percentage value | ImgPhasResltnPercentVal | The value in percent of the phase resolution used in imaging acquisition | The value in percent of the phase resolution used in imaging acquisition | DTI sequence parameters, Phase resolution | Numeric Values |
Answer should be recorded as a percent (%). Must be answered with Partial Fourier. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
percent | |||||||||
C10682 | Imaging anatomic site | ImgAnatSite | Anatomic site of body part or anatomy scanned in the imaging study | Anatomic site of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:09.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C17795 | Imaging diffusion third b value | ImgDiffusionThirdBVal | Value, in square millimeters per second, of the third b-value used in diffusion acquisition | Value, in square millimeters per second, of the third b-value used in diffusion acquisitio | DTI sequence parameters, third b-value | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | DTI sequence parameters, Field of view | Numeric Values |
Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C18703 | Imaging parallel acquisition used other text | ImgParallelAcquistionMethodOTH | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10586 | Imaging bandwidth value | ImgBandwidthVal | Value, in Hertz per pixel, of bandwidth used in imaging acquisition | Value, in Hertz per pixel, of bandwidth used in imaging acquisitio | DTI sequence parameters, Band width | Numeric Values |
Answer should be recorded in Hx/Pixel |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C10683 | Imaging T2 weighted spin-echo acquired indicator | ImgT2WSpinEchoAcquireInd | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correctio | T2-weighted spin-echo acquired | Yes;No | Yes;No | Alphanumeric |
For B0-susceptibility distortion correction. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |