CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10588 Imaging echo train length measurement ImgEchoTrainLngthMeasr Measurement of the echo train length used in imaging acquisition Measurement of the echo train length used in imaging acquisition DTI sequence parameters, Echo spacing, Echo train length Numeric Values

EPI factor

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18714 Imaging radio frequency coil channel count other text ImgRFCoilChannelCtOTH The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 2.00 2022-06-29 16:40:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10687 Imaging diffusion first b value ImgDiffusionFirstBVal Value, in square millimeters per second, of the first b-value used in diffusion acquisition Value, in square millimeters per second, of the first b-value used in diffusion acquisitio DTI sequence parameters, first b-value Numeric Values

Answer should be recorded in mm2/s

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C08245 Imaging slice count ImgSliceCt Count representing the total number of single image planes captured during imaging acquisition Count representing the total number of single image planes captured during imaging acquisition DTI sequence parameters, Number of slices Numeric Values

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C17811 Imaging phase partial Fourier value ImgPhasPartialFourierVal Value of the phase partial Fourier ratio, if used in imaging acquisition Value of the phase partial Fourier ratio, if used in imaging acquisition Partial Fourier Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10589 Imaging shot count ImgShotCt The number of shots used in the imaging echo-planner acquisition The number of shots used in the imaging echo-planner acquisition DTI sequence parameters, Echo spacing, No. of shots: Numeric Values

Must be answered with Echo Spacing and Echo Train Length

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18715 Imaging radio frequency coil other text ImgRFCoilOTH The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned Other, specify Alphanumeric

Check all that apply.

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10691 Imaging spatially registered template indicator ImgSptllyRegistrTmpltInd Indicator as to whether or not imaging is spatially registered to a template for data analysis Indicator as to whether or not imaging is spatially registered to a template for data analysi Spatially registered to a template for data analysis Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Magnetic Field Strength of Scanner Used 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10567 Imaging radio frequency coil type ImgRFCoilTyp Type of radio frequency (RF) coil(s) used for the body part scanned Type of radio frequency (RF) coil(s) used for the body part scanned RF Receiver coil(s) and number of channels Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify Alphanumeric

Check all that apply.

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:34.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C17925 Imaging contrast agent dose ImgContrastAgentDose Dosage of the contrast agent used Dosage of the contrast agent used Contrast Used: If Yes, dosage Numeric Values No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:39.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10590 Imaging interpolation indicator ImgInterpolationInd Whether the k-space data were interpolated before applying Fourier transform Whether the k-space data were interpolated before applying Fourier transfor DTI sequence parameters, Interpolation Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10842 Imaging analysis software name ImgAnlysisSftwrName Name of the software used for data processing or analysis of the imaging study Name of the software used for data processing or analysis of the imaging stud Software used Scanner provided;FSL;DtiStudio;Other, specify Scanner provided;FSL;DtiStudio;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Name of the scanner manufacturer GE;Siemens;Philips;Toshiba;Other, specify GE;Siemens;Philips;Toshiba;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10568 Imaging radio frequency coil channel count ImgRFCoilChannelCt Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of channels 1;8;12 channels;16;24;32 channels;Other, specify Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18610 Imaging in plane resolution axis 2 measurement ImgInPlaneRsltnAxis2Measr Axis 2 of in-plane spatial resolution used in imaging acquisition Axis 2 of in-plane spatial resolution used in imaging acquisition In-plane resolution Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 1.00 2013-09-12 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10591 Imaging phase encode direction text ImgPhasEncdeDirctTxt Text description of the phase encode direction used in imaging technique acquisition Text description of the phase encode direction used in imaging technique acquisition Phase-encode direction Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10963 Imaging B0-susceptibility distortion correction indicator ImgB0SuscDistortCorrInd Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio DWI co-registered to T2 image for B0-susceptibility distortion correction Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02498 Imaging scanner software version number text ImgScannerSftwrVrsnNumTxt Free-text field specifying the version number of the imaging scanner software Free-text field specifying the version number of the imaging scanner software Name of the scanner software and its version number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator of whether an imaging contrast agent was used for the scan Indicator as to whether or not an imaging contrast agent was used for the scan Contrast Used Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric

Choose one. If yes, record the name of the contrast agent and its dosage.

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18611 Imaging field of view axis 2 measurement ImgFieldViewAxis2Measr Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters Field of view Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 1.00 2013-09-12 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10592 Imaging flow compensation indicator ImgFlowCompnsatnInd Indicator of whether flow compensation was used in imaging acquisition Indicator of whether flow compensation was used in imaging acquisition Flow compensation Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18719 Imaging slice orientation type other text ImgSliceOrientTypOTH The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 15:08:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10964 Imaging eddy current induced spectral distortion correction indicator ImgEddyCurIndSpDCoInd Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation DWI co-registered to b=0 image and corrected for subject motion and eddy current induced distortion (affine transformation) Yes;No Yes;No Alphanumeric

Affine transformation

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used DTI sequence parameters, Sequence: Spin echo;STEAM;Other, specify Spin echo;STEAM;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition DTI sequence parameters, In-plane resolution Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
C18656 Imaging diffusion fifth b value ImgDiffusionFifthBVal Value, in square millimeters per second, of the fifth b-value used in diffusion acquisition Value, in square millimeters per second, of the fifth b-value used in diffusion acquisitio Numeric Values Adult;Pediatric Supplemental 1.00 2014-01-08 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10593 Imaging fat signal suppressed indicator ImgFatSignalSuppressedInd Indicator as to whether or not fat signal was suppressed in imaging acquisition Indicator as to whether or not fat signal was suppressed in imaging acquisition Fat signal suppressed Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C15572 Imaging diffusion direction count ImgDiffusionDirCt Count of diffusion directions in the associated diffusion imaging study Count of diffusion directions in the associated diffusion imaging study DTI sequence parameters, Number of diffusion-weighting gradient directions Numeric Values

Record the number of diffusion-weighting gradient directions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name of the scanner software Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10577 Imaging signal averages number ImgSignalAvgNum Number of signal acquisitions averaged in imaging acquisition Number of signal acquisitions averaged in imaging acquisition DTI sequence parameters, Number of signal averages Numeric Values

Record the number of signal averages

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18657 Imaging diffusion sixth b value ImgDiffusionSixthBVal Value, in square millimeters per second, of the sixth b-value used in diffusion acquisition Value, in square millimeters per second, of the sixth b-value used in diffusion acquisitio Numeric Values Adult;Pediatric Supplemental 1.00 2014-01-08 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10594 Imaging parallel acquisition used indicator ImgParallelAcquistionUsedInd Indicator of whether a parallel acquisition method is used in imaging acquisition Indicator of whether a parallel acquisition method is used in imaging acquisition Parallel acquisition used Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17793 Imaging diffusion fourth b value ImgDiffusionFourthBVal Value, in square millimeters per second, of the fourth b-value used in diffusion acquisition Value, in square millimeters per second, of the fourth b-value used in diffusion acquisitio DTI sequence parameters, fourth b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition DTI sequence parameters, Repetition time Numeric Values

TR

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10583 Imaging base resolution value ImgBaseResolutionVal Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI) Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI DTI sequence parameters, Base resolution Numeric Values

Answer should be recorded in points

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

point
C18689 Imaging anatomic site other text ImgAnatSiteOTH The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.10 2024-02-29 15:53:09.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10595 Imaging parallel acquisition used type ImgParallelAcquistionMethodTyp Type of the parallel acquisition method used in imaging acquisition Type of the parallel acquisition method used in imaging acquisitio If yes, method used GRAPPA;SENSE;Other, specify Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA);Sensitivity Encoding SENSE;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17794 Imaging diffusion second b value ImgDiffusionSecondBVal Value, in square millimeters per second, of the second b-value used in diffusion acquisition Value, in square millimeters per second, of the second b-value used in diffusion acquisitio DTI sequence parameters, second b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition DTI sequence parameters, Echo time Numeric Values

TE

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10584 Imaging phase resolution percentage value ImgPhasResltnPercentVal The value in percent of the phase resolution used in imaging acquisition The value in percent of the phase resolution used in imaging acquisition DTI sequence parameters, Phase resolution Numeric Values

Answer should be recorded as a percent (%). Must be answered with Partial Fourier.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C18690 Imaging analysis software other text ImgAnlysisSftwrOTH The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging study The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging stud Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10682 Imaging anatomic site ImgAnatSite Anatomic site of body part or anatomy scanned in the imaging study Anatomic site of body part or anatomy scanned in the imaging study Body part scanned Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:53:09.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters DTI sequence parameters, Field of view Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17795 Imaging diffusion third b value ImgDiffusionThirdBVal Value, in square millimeters per second, of the third b-value used in diffusion acquisition Value, in square millimeters per second, of the third b-value used in diffusion acquisitio DTI sequence parameters, third b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10586 Imaging bandwidth value ImgBandwidthVal Value, in Hertz per pixel, of bandwidth used in imaging acquisition Value, in Hertz per pixel, of bandwidth used in imaging acquisitio DTI sequence parameters, Band width Numeric Values

Answer should be recorded in Hx/Pixel

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz per pixel
C18703 Imaging parallel acquisition used other text ImgParallelAcquistionMethodOTH The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10683 Imaging T2 weighted spin-echo acquired indicator ImgT2WSpinEchoAcquireInd Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correctio T2-weighted spin-echo acquired Yes;No Yes;No Alphanumeric

For B0-susceptibility distortion correction.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

CSV