CDE Detailed Report

Disease: content
Subdomain Name: Imaging Diagnostics
CRF: welcome

Displaying 51 - 57 of 57
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition DTI sequence parameters, Echo time Numeric Values

TE

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C17794 Imaging diffusion second b value ImgDiffusionSecondBVal Value, in square millimeters per second, of the second b-value used in diffusion acquisition Value, in square millimeters per second, of the second b-value used in diffusion acquisitio DTI sequence parameters, second b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10584 Imaging phase resolution percentage value ImgPhasResltnPercentVal The value in percent of the phase resolution used in imaging acquisition The value in percent of the phase resolution used in imaging acquisition DTI sequence parameters, Phase resolution Numeric Values

Answer should be recorded as a percent (%). Must be answered with Partial Fourier.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C18690 Imaging analysis software other text ImgAnlysisSftwrOTH The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging study The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging stud Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10682 Imaging anatomic site ImgAnatSite Anatomic site of body part or anatomy scanned in the imaging study Anatomic site of body part or anatomy scanned in the imaging study Body part scanned Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:53:09.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters DTI sequence parameters, Field of view Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17795 Imaging diffusion third b value ImgDiffusionThirdBVal Value, in square millimeters per second, of the third b-value used in diffusion acquisition Value, in square millimeters per second, of the third b-value used in diffusion acquisitio DTI sequence parameters, third b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
CSV