CDE Detailed Report

Disease: content
Subdomain Name: Spinal Imaging/Spinal Cord Imaging
CRF: welcome

Displaying 1 - 33 of 33
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) Slice thickness Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

0 99 millimeter
C17793 Imaging diffusion fourth b value ImgDiffusionFourthBVal Value, in square millimeters per second, of the fourth b-value used in diffusion acquisition Value, in square millimeters per second, of the fourth b-value used in diffusion acquisitio b-value Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

square millimeter per second
C02494 Imaging study date and time ImgStdyDateTime Date (and time, if applicable and known) the radiologic study was obtained Date (and time, if applicable and known) the radiologic study was obtained Imaging study date and time Date or Date & Time Adult;Pediatric Supplemental 3.10 2024-02-29 15:51:00.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

C19370 Frequency field of view phase measurement FrequencyFOVPhaseMeasr Phase measurement of spatial encoding area of frequency image Phase measurement of spatial encoding area of frequency image Freq FOV mm Numeric Values Adult;Pediatric Supplemental 1.00 2014-06-13 11:04:57.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeters
C08245 Imaging slice count ImgSliceCt Count representing the total number of single image planes captured during imaging acquisition Count representing the total number of single image planes captured during imaging acquisition Number of slices Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

C17794 Imaging diffusion second b value ImgDiffusionSecondBVal Value, in square millimeters per second, of the second b-value used in diffusion acquisition Value, in square millimeters per second, of the second b-value used in diffusion acquisitio b-value Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

square millimeter per second
C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Magnetic field strength of scanner used 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C10586 Imaging bandwidth value ImgBandwidthVal Value, in Hertz per pixel, of bandwidth used in imaging acquisition Value, in Hertz per pixel, of bandwidth used in imaging acquisitio Band width Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

Hertz per pixel
C17795 Imaging diffusion third b value ImgDiffusionThirdBVal Value, in square millimeters per second, of the third b-value used in diffusion acquisition Value, in square millimeters per second, of the third b-value used in diffusion acquisitio b-value Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

square millimeter per second
C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Name of scanner manufacturer Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify Alphanumeric Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C10588 Imaging echo train length measurement ImgEchoTrainLngthMeasr Measurement of the echo train length used in imaging acquisition Measurement of the echo train length used in imaging acquisition Echo train length Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

C17858 Imaging voxel size axis 2 measurement ImgVoxelSizeAxis2Measr Measurement, in millimeters, of the axis 2 dimension of the voxel within the anatomy of interest Measurement, in millimeters, of the axis 2 dimension of the voxel within the anatomy of interest Voxel size Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C02498 Imaging scanner software version number text ImgScannerSftwrVrsnNumTxt Free-text field specifying the version number of the imaging scanner software Free-text field specifying the version number of the imaging scanner software Version number Alphanumeric Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations 4000

Free-Form Entry

C10591 Imaging phase encode direction text ImgPhasEncdeDirctTxt Text description of the phase encode direction used in imaging technique acquisition Text description of the phase encode direction used in imaging technique acquisition Phase-encode direction Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations 4000

Free-Form Entry

C17859 Imaging voxel size axis 3 measurement ImgVoxelSizeAxis3Measr Measurement, in millimeters, of the axis 3 dimension of the voxel within the anatomy of interest Measurement, in millimeters, of the axis 3 dimension of the voxel within the anatomy of interest Voxel size Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used Sequence rFOV;EPI;Spin echo Reduced field of view (rFOV);Echo Planar Imaging (EPI);Spin echo Alphanumeric Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Multiple Pre-Defined Values Selected

C10592 Imaging flow compensation indicator ImgFlowCompnsatnInd Indicator of whether flow compensation was used in imaging acquisition Indicator of whether flow compensation was used in imaging acquisition Flow comp Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C18611 Imaging field of view axis 2 measurement ImgFieldViewAxis2Measr Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters Matrix size Numeric Values Adult;Pediatric Supplemental 1.00 2013-09-12 00:00:00.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations 4000

Free-Form Entry

C10593 Imaging fat signal suppressed indicator ImgFatSignalSuppressedInd Indicator as to whether or not fat signal was suppressed in imaging acquisition Indicator as to whether or not fat signal was suppressed in imaging acquisition Fat suppression Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other Alphanumeric Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations 4000

Free-Form Entry

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Repetition time (TR) Numeric Values Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millisecond
C10685 Imaging slice orientation type ImgSliceOrientTyp Type of slice orientation used in imaging acquisition Type of slice orientation used in imaging acquisition Slide orientation Axial;Coronal;Sagittal;Oblique Axial;Coronal;Sagittal;Oblique Alphanumeric Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:40.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other Alphanumeric Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations 4000

Free-Form Entry

C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Echo time (TE) Numeric Values Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millisecond
C10687 Imaging diffusion first b value ImgDiffusionFirstBVal Value, in square millimeters per second, of the first b-value used in diffusion acquisition Value, in square millimeters per second, of the first b-value used in diffusion acquisitio b-value Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

square millimeter per second
C19326 Imaging frame of reference type ImgFrameReferenceTyp The type related to imaging of frame of reference The type related to imaging of frame of referenc Frame of reference Orthogonal;Rotated Orthogonal;Rotated Alphanumeric Adult;Pediatric Supplemental 1.00 2014-06-09 16:03:36.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Single Pre-Defined Value Selected

C08240 Imaging flip angle measurement ImgFlipAngleMeasr Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle Measurement of the angle, in degrees over which the radio frequency changes proton spin angle FA Numeric Values Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

degree
C10837 Imaging gap between slices measurement ImgGapBetwnSlicesMeasr Measurement of the gap between slices used in imaging acquisition Measurement of the gap between slices used in imaging acquisition Slice gap Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C19331 Imaging number of excitations count ImgNEXCt The count as related to number of diffusion tensor imaging acquisitions or number of excitations The count as related to number of diffusion tensor imaging acquisitions or number of excitation NEX Numeric Values Adult;Pediatric Supplemental 1.00 2014-06-09 16:43:30.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

0 5
C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Matrix size Numeric Values Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C10838 Imaging voxel size axis 1 measurement ImgVoxelSizeAxis1Measr Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest Voxel size Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

millimeter
C19332 Imaging two dimensional radio frequency tilt angle measurement ImgTwoDimRadFreqTiltAngleMeasr The measurement in degree for the two dimensional radio frequency tilt angle in imaging The measurement in degree for the two dimensional radio frequency tilt angle in imagin 2DRF tilt angle Numeric Values Adult;Pediatric Supplemental 1.00 2014-06-09 17:06:30.0 Diffusion Tensor Imaging Spinal Imaging/Spinal Cord Imaging Assessments and Examinations

Free-Form Entry

0 360 degree
CSV