CDE Detailed Report

Disease: content
Subdomain Name: Non-Imaging Diagnostics
CRF: welcome

Displaying 1 - 50 of 88
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C12720 Electrophysiology repetitive nerve stimulation study preactivation area measurement ElctphyRptvNrvStmStPreacArMeas Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded Preactivation Area Numeric Values

Record the area of the response in millivolt milliseconds (mVms) To be answered for preactivation #1, #n, and 1-n?

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt per millisecond
C12755 Electrophysiology Valsalva ratio ElctphysValslvaRatio The Valsalva ratio measured during autonomic function testing The Valsalva ratio measured during autonomic function testing Valsalva Ratio Numeric Values

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C02411 Laterality type LatTyp Laterality type relative to the anatomic site of the body examined or affected Laterality type relative to the anatomic site of the body examined or affected Side Left;Right;Midline Left;Right;Midline Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12698 Electrophysiology motor nerve segment length measurement ElctphysMotrNervSegmtLngMeasr The nerve segment length measured during the motor nerve conduction study The nerve segment length measured during the motor nerve conduction study Segment Length Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

centimeter
C12731 Needle electromyography motor unit action potential area measurement NdlElctrmygrphyMUAPAreaMeasr The area value of the motor unit action potential (MUAP) measure during needle electromyography The area value of the motor unit action potential (MUAP) measure during needle electromyography MUAP: Area Numeric Values

Record the area in microvolt milliseconds (uVms). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt per millisecond
C12766 Electrophysiology short pre-exercise compound muscle action potential measurement ElctphysShrtPreExercsCMAPMeasr The compound muscle action potential (CMAP) values measured at the pre-exercise intervals The compound muscle action potential (CMAP) values measured at the pre-exercise intervals Pre-Exercise Numeric Values

To be answered for all pre-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12709 Electrophysiology blink reflex test electrode type ElctphysBlnkReflxTstElectrdTyp Type of electrode used for the blink reflex test Type of electrode used for the blink reflex test Recording Electrode Needle;Surface Needle;Surface Alphanumeric

Record the electrode type - choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12742 Electrophysiology neuromuscular jitter pair or endplate study count ElctphyNeurmsJttrPrEndpltStdCt Count of the pairs/endplates studied in the neuromuscular jitter study being described Count of the pairs/endplates studied in the neuromuscular jitter study being described Number of pairs endplates studied Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12721 Electrophysiology repetitive nerve activation technique type ElctphysReptvNervActvtTechnTyp Indicator of the activation technique used in the repetitive nerve study being recorded Indicator of the activation technique used in the repetitive nerve study being recorded Activation Technique Maximum contraction;High frequency stimulation Maximum contraction;High frequency stimulation Alphanumeric

Record the technique used for repetitive stimulation

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12756 Electrophysiology blood pressure response Valsalva phase II early result ElctphysBPRespValslvaPh2ErlRes The blood pressure response to valsalva maneuver during Phase II early The blood pressure response to Valsalva maneuver during Phase II early Blood Pressure Response to Valsalva Maneuver - Phase II early Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10777 Electrophysiology study type ElctrophysStdyTyp Type of electrophysiology study conducted Type of electrophysiology study conducted Study Motor nerve conduction study;Sensory nerve conduction study;H-reflex study;Blink reflex test;Repetitive nerve stimulation study;Needle electromyography;Neuromuscular jitter study;Fiber density;Motor unit number estimation (MUNE);Autonomic function testing;Short exercise test;Long exercise test Motor nerve conduction study;Sensory nerve conduction study;H-reflex study;Blink reflex test;Repetitive nerve stimulation study;Needle electromyography;Neuromuscular jitter study;Fiber density;Motor unit number estimation (MUNE);Autonomic function testing;Short exercise test;Long exercise test Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12699 Electrophysiology motor nerve amplitude measurement ElctphysMotrNervAmpMeasr The measured amplitude of signal response to test stimulation during the motor nerve conduction study The measured amplitude of signal response to test stimulation during the motor nerve conduction study Amplitude (normal limit) Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt
C12732 Needle electromyography motor unit action potential duration NdlElctrmygrphyMUAPDur The duration of the motor unit action potential during needle electromyography The duration of the action potential measure during needle electromyography MUAP: Duration Numeric Values

Record the duration in milliseconds (ms). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12767 Electrophysiology short post-exercise compound muscle action potential time ElctphysShrtPostExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the short exercise test The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the short exercise test Post-Exercise CMAP immediately;CMAP 10 seconds;CMAP 20 seconds;CMAP 30 seconds;CMAP 40 seconds;CMAP 50 seconds;CMAP 60 seconds CMAP immediately;CMAP 10 seconds;CMAP 20 seconds;CMAP 30 seconds;CMAP 40 seconds;CMAP 50 seconds;CMAP 60 seconds Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12710 Electrophysiology assessment date and time ElctrophysAssmtDateTime Date the particular electrophysiology study was performed Date the particular electrophysiology study was performed Date of Test Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12743 Electrophysiology neuromuscular jitter mean consecutive difference average value ElctphysNeurmscJttrMCDAvgVal Value, in microseconds, for the average of mean consecutive differences (MCD) recorded for the neuromuscular jitter study being described Value, in microseconds, for the average of mean consecutive differences (MCD) recorded for the neuromuscular jitter study being described Mean MCD Numeric Values

Record the mean MCD in microseconds (us). Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12722 Electrophysiology repetitive nerve high frequency ElctphysReptveNervHighFreq Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded If High frequency stimulation specify frequency used Numeric Values

This value is only recorded if High frequency stimulation is answered for Activation Technique. Record the frequency in Hertz (Hz).

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C12757 Electrophysiology blood pressure response Valsalva phase II late result ElctphysBPRespValslvPh2LateRes The blood pressure response to valsalva maneuver during Phase II late The blood pressure response to Valsalva maneuver during Phase II late Blood Pressure Response to Valsalva Maneuver - Phase II late Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10778 Electrophysiology motor unit number estimation muscle studied name ElctPhysMUNEMuscleStudiedName Name of the muscle studied using the MUNE (motor unit number estimation) technique Name of the muscle studied using the MUNE (motor unit number estimation) technique Muscle Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12700 Electrophysiology motor nerve dispersion result ElctphysMotrNervDisprsnReslt Amount of test signal dispersion measured during the motor nerve conduction study Amount of test signal dispersion measured during the motor nerve conduction study Dispersed? Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12733 Needle electromyography motor unit action potential complexity percent value NdlElctrmygrpMUAPCompxtyPctVal The complexity of the motor unit action potential measured during needle electromyography The complexity of the action potential measured during needle electromyography MUAP: Complexity Numeric Values

Record the complexity as a percentage (%). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C12768 Electrophysiology short post-exercise compound muscle action potential measurement ElctphyShrtPostExercsCMAPMeasr The compound muscle action potential (CMAP) values measured at the post-exercise intervals The compound muscle action potential (CMAP) values measured at the post-exercise intervals Post-Exercise Numeric Values

To be answered for all post-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12712 Electrophysiology blink reflex test R1 latency value ElctphysBlnkReflxTstR1LatncVal Duration of R1 latency in the blink reflex test Duration of R1 latency in the blink reflex test R one Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12744 Electrophysiology neuromuscular jitter mean consecutive difference abnormal count ElctphysNeurmscJttrMCDAbnrmlCt Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described Number with Abnormal MCD Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12723 Electrophysiology repetitive nerve activation duration ElctphysReptveNervActvtnDur Duration, in sec, of the activation technique used in the repetitive nerve study being recorded Duration, in sec, of the activation technique used in the repetitive nerve study being recorded Activation Duration Numeric Values

Record the duration of activation in seconds (sec)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

second
C12758 Electrophysiology blood pressure response Valsalva phase IV result ElctphysBPRespValslvapPhas4Res The blood pressure response to valsalva maneuver during Phase IV The blood pressure response to Valsalva maneuver during Phase IV Blood Pressure Response to Valsalva Maneuver - Phase IV Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10780 Electrophysiology anatomic site ElctrophysAntmicSite Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed Nerve Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12701 Electrophysiology motor nerve F-wave minimum latency value ElctphyMotrNervFwavMinLatncVal The length of time needed for the impulse to travel from the site, to the spine, and back to the site measured during the motor nerve conduction study The length of time needed for the impulse to travel from the site, to the spine, and back to the site measured during the motor nerve conduction study F wave minimum latency Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12734 Needle electromyography motor unit action potential stable indicator NdlElctrmygrphyMUAPStablInd The stability of the action potential measure during needle electromyography The stability of the action potential measure during needle electromyography MUAPs: Stable Yes;No Yes;No Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12769 Electrophysiology long pre-exercise compound muscle action potential time ElctphysLngPreExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the long exercise test The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the long exercise test Pre-Exercise CMAP 3 minutes;CMAP 2 minutes;CMAP 1 minute CMAP 3 minutes;CMAP 2 minutes;CMAP 1 minute Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12713 Electrophysiology blink reflex test ipsilateral R2 latency value ElctphysBlnkRefTstIpslR2LatVal Duration of ipsilateral R2 latency in the blink reflex test Duration of ipsilateral R2 latency in the blink reflex test Ipsilateral R two Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12745 Electrophysiology neuromuscular jitter study blocking count ElctphysNeurmscJttrStdyBlockCt Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described Number with Blocking Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12724 Electrophysiology repetitive nerve postactivation elapsed time duration ElctphyReptvNrvPstacElpsdTmDur Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded Postactivation Time Numeric Values

Record postactivation time in the format hours:minutes:seconds (HH:MM:SS)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C12759 Electrophysiology quantitative sweat function forearm measurement ElctphyQuantSweatFuncFarmMeasr The amount of sweat collected on the forearm The amount of sweat collected on the forearm Forearm Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10782 Electrophysiology motor unit number estimation method used type ElctphysMUNEMethdUseTyp Type of method or technique used for MUNE (motor unit number estimation) Type of method or technique used for MUNE (motor unit number estimation) Technique Used Incremental;Multipoint;Statistical;Other, specify Incremental;Multipoint;Statistical;Other, specify Alphanumeric

Choose one for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12702 Electrophysiology sensory nerve impulse direction type ElctphysSensryNervImpulsDirTyp The impulse direction put on the nerve during the sensory nerve conduction study The impulse direction put on the nerve during the sensory nerve conduction study Impulse Direction Orthodromic;Antidromic Orthodromic;Antidromic Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12735 Needle electromyography motor unit action potential recruitment type NdlElctrmygrphyMUAPRecrtmntTyp The recruitment of the motor unit action potential measure during needle electromyography The recruitment of the action potential measure during needle electromyography MUAP: Recruitment Normal;Increased/Early;Decreased Normal;Increased/Early;Decreased Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12770 Electrophysiology long pre-exercise compound muscle action potential measurement ElctphysLngPreExercsCMAPMeasr Compound muscle action potential (CMAP) measurement recorded pre- long exercise Compound muscle action potential (CMAP) measurement recorded pre- long exercise Pre-Exercise Numeric Values

To be answered for all pre-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12714 Electrophysiology blink reflex test contralateral R2 latency value ElctphyBlnkReflTstContR2LatVal Duration of contralateral R2 latency in the blink reflex test Duration of contralateral R2 latency in the blink reflex test Contralateral R two Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12746 Electrophysiology fiber density quantitative result value ElctphysFiberDnstyQuantRsltVal Fiber density measured for a particular muscle and side Fiber density measured for a particular muscle and side Fiber Density Numeric Values

Record for each muscle/side tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12725 Electrophysiology repetitive nerve postactivation number ElctphysReptveNervPstactvtnNum The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study Postactivation Number Numeric Values

Record the correct number in the series of postactivation timepoints

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12760 Electrophysiology quantitative sweat function proximal leg measurement ElctphyQuanSweatFuncPrxLegMeas The amount of sweat collected on the proximal leg The amount of sweat collected on the proximal leg Proximal Leg Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10783 Electrophysiology motor unit number estimation compound muscle action potential measurement ElctphysMUNECMAPMeasr Measurement in millivolts (mV) of the compound muscle action potential (CMAP) amplitude for the muscle on which MUNE (motor unit number estimation) is performed Measurement in millivolts (mV) of the compound muscle action potential (CMAP) amplitude for the muscle on which MUNE (motor unit number estimation) is performed CMAP Numeric Values

Record in microvolts (?V) for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12703 Electrophysiology sensory nerve segment length measurement ElctphysSensNervSegmtLgthMeasr The sensory nerve segment length measured during the sensory nerve conduction study The sensory nerve segment length measured during the sensory nerve conduction study Segment Length Numeric Values

Record the length in centimeters (cm). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

centimeter
C12736 Needle electromyography motor unit action potential activation type NdlElctrmygrphyMUAPActvtnTyp The activation of the motor unit action potential measure during needle electromyography The activation of the action potential measure during needle electromyography MUAP: Activation Normal;Decreased Normal;Decreased Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12771 Electrophysiology long exercise test post-exercise compound muscle action potential time ElctphysLngPostExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise for the long exercise test The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise for the long exercise test Post-Exercise CMAP immediately;CMAP 1 minute;CMAP 2 minutes;CMAP 3 minutes;CMAP 4 minutes;CMAP 5 minutes;CMAP 6 minutes;CMAP 7 minutes;CMAP 8 minutes;CMAP 9 minutes;CMAP 10 minutes;CMAP 11 minutes;CMAP 12 minutes;CMAP 13 minutes;CMAP 14 minutes;CMAP 15 minutes;CMAP 16 minutes;CMAP 17 minutes;CMAP 18 minutes;CMAP 19 minutes;CMAP 20 minutes;CMAP 21 minutes;CMAP 22 minutes;CMAP 23 minutes;CMAP 24 minutes;CMAP 25 minutes;CMAP 26 minutes;CMAP 27 minutes;CMAP 28 minutes;CMAP 29 minutes;CMAP 30 minutes;CMAP 31 minutes;CMAP 32 minutes;CMAP 33 minutes;CMAP 34 minutes;CMAP 35 minutes;CMAP 36 minutes;CMAP 37 minutes;CMAP 38 minutes;CMAP 39 minutes;CMAP 40 minutes;CMAP 41 minutes;CMAP 42 minutes;CMAP 43 minutes;CMAP 44 minutes;CMAP 45 minutes;CMAP 46 minutes;CMAP 47 minutes;CMAP 48 minutes;CMAP 49 minutes;CMAP 50 minutes;CMAP 51 minutes;CMAP 52 minutes;CMAP 53 minutes;CMAP 54 minutes;CMAP 55 minutes;CMAP 56 minutes;CMAP 57 minutes;CMAP 58 minutes;CMAP 59 minutes;CMAP 60 minutes CMAP immediately;CMAP 1 minute;CMAP 2 minutes;CMAP 3 minutes;CMAP 4 minutes;CMAP 5 minutes;CMAP 6 minutes;CMAP 7 minutes;CMAP 8 minutes;CMAP 9 minutes;CMAP 10 minutes;CMAP 11 minutes;CMAP 12 minutes;CMAP 13 minutes;CMAP 14 minutes;CMAP 15 minutes;CMAP 16 minutes;CMAP 17 minutes;CMAP 18 minutes;CMAP 19 minutes;CMAP 20 minutes;CMAP 21 minutes;CMAP 22 minutes;CMAP 23 minutes;CMAP 24 minutes;CMAP 25 minutes;CMAP 26 minutes;CMAP 27 minutes;CMAP 28 minutes;CMAP 29 minutes;CMAP 30 minutes;CMAP 31 minutes;CMAP 32 minutes;CMAP 33 minutes;CMAP 34 minutes;CMAP 35 minutes;CMAP 36 minutes;CMAP 37 minutes;CMAP 38 minutes;CMAP 39 minutes;CMAP 40 minutes;CMAP 41 minutes;CMAP 42 minutes;CMAP 43 minutes;CMAP 44 minutes;CMAP 45 minutes;CMAP 46 minutes;CMAP 47 minutes;CMAP 48 minutes;CMAP 49 minutes;CMAP 50 minutes;CMAP 51 minutes;CMAP 52 minutes;CMAP 53 minutes;CMAP 54 minutes;CMAP 55 minutes;CMAP 56 minutes;CMAP 57 minutes;CMAP 58 minutes;CMAP 59 minutes;CMAP 60 minutes Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12715 Electrophysiology repetitive nerve stimulation study stimulation rate value ElctphysReptNervStimulaRateVal Value, in Hz, of the stimulation rate used in the repetitive nerve study being recorded Value, in Hz, of the stimulation rate used in the repetitive nerve study being recorded Stimulation rate Numeric Values

Record the stimulation rate in Hertz (Hz)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C12747 Electrophysiology motor unit number estimation surface motor unit action potential average value ElctphysMUNEsMUAPAvgVal Average surface motor unit action potentials (sMUAPs), estimated using the designated MUNE (motor unit number estimation) technique Average surface motor unit action potentials (sMUAPs), estimated using the designated MUNE (motor unit number estimation) technique Average sMUAP Numeric Values

Record in microvolts (?V) for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt
C12726 Electrophysiology repetitive nerve postactivation amplitude measurement ElctphyReptNervPstactvAmpMeasr Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Postactivation Amplitude Numeric Values

Record the amplitude of the response to Postactivation stimulus in millivolts (mV). Record the amplitude for postactivation #1, #n, and 1-n ? for each postactivation timepoint.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12761 Electrophysiology quantitative sweat function distal leg measurement ElctphyQuanSweatFuncDistLMeasr The amount of sweat collected on the distal leg The amount of sweat collected on the distal leg Distal Leg Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
CSV