CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10785 Electrophysiology motor unit number estimation value ElctphysMUNEVal Value of the motor unit number estimate (MUNE), derived by dividing compound muscle action potential (CMAP) amplitude by single motor unit potential (SMUP) amplitude Value of the motor unit number estimate (MUNE), derived by dividing compound muscle action potential (CMAP) amplitude by single motor unit potential (SMUP) amplitude MUNE Numeric Values

Record the calculated MUNE value for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12726 Electrophysiology repetitive nerve postactivation amplitude measurement ElctphyReptNervPstactvAmpMeasr Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Postactivation Amplitude Numeric Values

Record the amplitude of the response to Postactivation stimulus in millivolts (mV). Record the amplitude for postactivation #1, #n, and 1-n ? for each postactivation timepoint.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12761 Electrophysiology quantitative sweat function distal leg measurement ElctphyQuanSweatFuncDistLMeasr The amount of sweat collected on the distal leg The amount of sweat collected on the distal leg Distal Leg Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C12704 Electrophysiology sensory nerve onset or peak latency value ElctphysSensNervOnsPkLatncVal The onset or peak latency measured during the sensory nerve conduction study The onset or peak latency measured during the sensory nerve conduction study Onset or Peak Latency Numeric Values

Record the onset or peak latency in milliseconds (ms). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12737 Needle electromyography interference pattern analysis technique name NdlElctrmygInterfPtrnAnlTchNam The interference pattern technique used for analysis measure during needle electromyography The interference pattern technique used for analysis measure during needle electromyography Interference Pattern Analysis Technique Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12772 Electrophysiology long exercise test post-exercise compound muscle action potential measurement ElctphysLngPostExercsCMAPMeasr Compound muscle action potential (CMAP) measurement recorded post- long exercise Compound muscle action potential (CMAP) measurement recorded post- long exercise Post-Exercise Numeric Values

To be answered for all post-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12716 Electrophysiology repetitive nerve stimulation study stimulus duration ElctphysReptveNervStimStdyDur Duration, in ?s, of stimulation in the repetitive nerve study being recorded Duration, in ?s, of stimulation in the repetitive nerve study being recorded Stimulus Duration Numeric Values

Record the duration of the stimulus in microseconds (us)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12750 Electrophysiology motor unit number estimation surface motor unit action potential average count ElctphysMUNEsMUAPAvgCt Number of surface motor unit action potentials (sMUAPs) averaged to arrive at the average sMUAP value Number of surface motor unit action potentials (sMUAPs) averaged to arrive at the average sMUAP value Number of sMUAPs averaged Numeric Values

Record for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10786 Electrophysiology motor unit number estimation nerve type ElctphysMUNENervTyp Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique Nerve Stimulated Axillary;Facial;Femoral;Mandibular;Maxillary;Median;Perineal;Radial;Sciatic;Tibial;Ulnar;Other, specify Axillary;Facial;Femoral;Mandibular;Maxillary;Median;Perineal;Radial;Sciatic;Tibial;Ulnar;Other, specify Alphanumeric

Record the CMAP and SMUP measurements for each nerve and side (right or left)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12727 Electrophysiology repetitive nerve postactivation area measurement ElctphyReptNervPstactAreaMeasr Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded Postactivation Area Numeric Values

Record the amplitude of the response to Postactivation stimulus in millivolts (mV). Record the amplitude for postactivation #1, #n, and 1-n ? for each postactivation timepoint.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt per millisecond
C12762 Electrophysiology quantitative sweat function foot measurement ElctphysQuantSweatFunctFtMeasr The amount of sweat collected on the foot The amount of sweat collected on the foot Foot Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C12705 Electrophysiology sensory nerve velocity measurement EltrphysSensryNervVeloctyMeasr The signal transmission speed measured during the sensory nerve conduction study The signal transmission speed measured during the sensory nerve conduction study Velocity (normal limit) Numeric Values

Record the velocity in meters per second (m/s). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

meter per second
C12738 Needle electromyography interference pattern analysis result NdlElctrmygrInterfPttrnAnlyRes The result of the interference pattern analysis measure during needle electromyography The result of the interference pattern analysis measure during needle electromyography Interference Pattern Analysis Result Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C17969 Electrophysiology sensory nerve segment name ElctphysSensNervSegmntNam The name of the segment used in sensory nerve conduction studies The name of the segment used in motor or sensory nerve conduction studies Segment Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12717 Electrophysiology repetitive nerve stimulation study stimulus intensity value ElctphyReptNervStimStdyIntnVal Value, in mV, of stimulation intensity in the repetitive nerve study being recorded Value, in mV, of stimulation intensity in the repetitive nerve study being recorded Stimulus Intensity Numeric Values

Record the intensity of the stimulus in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12752 Electrophysiology heart rate variability value ElctphysHRVaribltyVal The heart rate variability with deep breathing measured during autonomic function testing The heart rate variability with deep breathing measured during autonomic function testing Heart Rate variability with Deep Breathing Numeric Values

Record the heart rate variability in beats/minute

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 300 beats per minute
C12693 Electrophysiology H-reflex nerve segment name ElctphysHReflxNervSegmtNam The nerve segment used for the H-reflex test The nerve segment used for the H-reflex test Nerve Segment Alphanumeric

Record the name of the nerve segment used for H-reflex testing

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12728 Needle electromyography electrode type NdlElctrmygrphyElectrdTyp Type of electrode used for the needle electromyography Type of electrode used for the needle electromyography Electrode Type Concentric;Monopolar Concentric;Monopolar Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12763 Electrophysiology tilt study heart rate change result ElctphysTiltStdyHRChngReslt Heart rate changes experienced from a tilt test Heart rate changes experienced from a tilt test Heart Rate changes Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12706 Electrophysiology sensory nerve amplitude measurement ElctphysSensryNervAmpMeasr The amplitude measured during the sensory nerve conduction study The amplitude measured during the sensory nerve conduction study Amplitude (normal limit) Numeric Values

Record the measured amplitude in millivolts (mV). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12739 Electrophysiology neuromuscular jitter electrode type ElctphysNeuromsJittrElectrdTyp The type of electrode used for the neuromuscular jitter test The type of electrode used for the neuromuscular jitter test Electrode Type SFEMG;Concentric Needle Single fiber electromyography (SFEMG);Concentric Needle Alphanumeric

Record the type of jitter electrode used

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18808 Electrophysiology motor unit number estimation method used other text ElctphysMUNEMethdUseOTH The free-text field related to 'Electrophysiology motor unit number estimation method used type' specifying other text. Type of method or technique used for MUNE (motor unit number estimation) The free-text field related to 'Electrophysiology motor unit number estimation method used type' specifying other text. Type of method or technique used for MUNE (motor unit number estimation) Other, specify Alphanumeric

Choose one for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12718 Electrophysiology repetitive nerve stimulation study preactivation number ElctphysReptNrvStimStdPreacNum The numeric identifier corresponding to the amplitude and area values recorded for preactivation during the repetitive nerve stimulation study The numeric identifier corresponding to the amplitude and area values recorded for preactivation during the repetitive nerve stimulation study Preactivation Numeric Values

Record the correct number in the series of preactivation timepoints

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12753 Electrophysiology expiratory inspiratory ratio ElctphysExpInspRat Ratio of the expiratory time to the inspiratory time during the breathing cycle measured during autonomic function testing Ratio of the expiratory time to the inspiratory time during the breathing cycle measured during autonomic function testing Expiratory/Inspiratory (E/I) Ratio Numeric Values

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C01539 Temperature measurement TempMeasr Measurement of the participant's/subject's body temperature Measurement of the participant's/subject's body temperatur Temperature Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 50 degree Celsius 2644401
C12696 Electrophysiology motor nerve segment name ElctphysMotrNervSegmntName The name of the segment used for the motor nerve conduction study The name of the segment used for the motor nerve conduction study Segment Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12729 Needle electromyography spontaneous activity type NdlElctrmygrphySATyp The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography Spontaneous Activity Fibrillation potentials;Positive sharp waves;Fasciculation potentials;Other, specify Fibrillation potentials;Positive sharp waves;Fasciculation potentials;Other, specify Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12764 Electrophysiology tilt study blood pressure change result ElctphysTiltStdyBPChngReslt Blood Pressure changes experienced from a tilt test Blood Pressure changes experienced from a tilt test Blood Pressure changes Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C18809 Electrophysiology motor unit number estimation nerve other text ElctphysMUNENervOTH The free-text field related to 'Electrophysiology motor unit number estimation nerve type' specifying other text. Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique The free-text field related to 'Electrophysiology motor unit number estimation nerve type' specifying other text. Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique Other, specify Alphanumeric

Record the CMAP and SMUP measurements for each nerve and side (right or left)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12707 Electrophysiology H-reflex latency left value ElctphysHReflxLatncyLftVal The H-reflex duration of latency for the left side of the body The H-reflex duration of latency for the left side of the body Latency left Numeric Values

Record the latency for the left side of the body in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12740 Electrophysiology neuromuscular jitter activation technique type ElctphyNeuromsJitrActvtTechTyp The activation technique used for the neuromuscular jitter test The activation technique used for the neuromuscular jitter test Activation Technique Voluntary;Stimulation Voluntary;Stimulation Alphanumeric

Record the activation technique used in jitter muscle test

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12719 Electrophysiology repetitive nerve stimulation study preactivation amplitude measurement ElctphRptvNrvStmStPreacAmpMeas Measurement, in mV, of the amplitude of the preactivation being described for the repetitive nerve study being recorded Measurement, in mV, of the amplitude of the preactivation being described for the repetitive nerve study being recorded Preactivation Amplitude Numeric Values

Record the amplitude in millivolts (mV) To be answered for preactivation #1, #n, and 1-n?

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12754 Electrophysiology mean circular result ElctphysMeanCircReslt The mean circular result (MCR) measured during autonomic function testing The mean circular result (MCR) measured during autonomic function testing Mean circular resultant Numeric Values

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C01580 Temperature unit of measure TempUOM Unit of measure for the temperature numerical value Unit of measure for the temperature numerical value Temperature units F;C degrees Fahrenheit;degrees Celsius Alphanumeric Unified Code for Units of Measure - http://unitsofmeasure.org/ Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

2956267
C12697 Electrophysiology motor nerve latency value ElctphysMotrNervLatncyVal The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study Latency (normal limit) Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12730 Needle electromyography motor unit action potential amplitude measurement NdlElctrmygrphyMUAPAmpMeasr The amplitude value of the motor unit action potential (MUAP) measure during needle electromyography The amplitude value of the motor unit action potential (MUAP) measure during needle electromyography MUAP: Amplitude Numeric Values

Record the amplitude in microvolts (uV). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt
C12765 Electrophysiology short pre-exercise compound muscle action potential time ElctphysShrtPreExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise Pre-Exercise CMAP 3 minutes;CMAP 2 minutes;CMAP 1 minute Compound motor actional potential (CMAP) at 3 minutes;Compound motor actional potential (CMAP) at 2 minutes;Compound motor actional potential (CMAP) at 1 minute Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18871 Needle electromyography spontaneous activity other text NdlElctrmygrphySAOTH The free-text field related to 'Needle electromyography spontaneous activity type' specifying other text. The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography The free-text field related to 'Needle electromyography spontaneous activity type' specifying other text. The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography Other, specify Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12708 Electrophysiology H-reflex latency right value ElctphysHReflxLatncyRtVal The H-reflex duration of latency for the right side of the body The H-reflex duration of latency for the right side of the body Latency right Numeric Values

Record the latency for the right side of the body in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12741 Electrophysiology neuromuscular jitter stimulation type ElctphysNeuromsclrJittrStimTyp Indicator of the stimulation technique, if applicable, used for activation in the neuromuscular jitter study being described Indicator of the stimulation technique, if applicable, used for activation in the neuromuscular jitter study being described If Stimulation, specify Axonal;Nerve Axonal (needle);Nerve (surface electrode) Alphanumeric

This value is only recorded if Stimulation is answered for Activation Technique.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12720 Electrophysiology repetitive nerve stimulation study preactivation area measurement ElctphyRptvNrvStmStPreacArMeas Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded Preactivation Area Numeric Values

Record the area of the response in millivolt milliseconds (mVms) To be answered for preactivation #1, #n, and 1-n?

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt per millisecond
C12755 Electrophysiology Valsalva ratio ElctphysValslvaRatio The Valsalva ratio measured during autonomic function testing The Valsalva ratio measured during autonomic function testing Valsalva Ratio Numeric Values

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C02411 Laterality type LatTyp Laterality type relative to the anatomic site of the body examined or affected Laterality type relative to the anatomic site of the body examined or affected Side Left;Right;Midline Left;Right;Midline Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12698 Electrophysiology motor nerve segment length measurement ElctphysMotrNervSegmtLngMeasr The nerve segment length measured during the motor nerve conduction study The nerve segment length measured during the motor nerve conduction study Segment Length Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

centimeter
C12731 Needle electromyography motor unit action potential area measurement NdlElctrmygrphyMUAPAreaMeasr The area value of the motor unit action potential (MUAP) measure during needle electromyography The area value of the motor unit action potential (MUAP) measure during needle electromyography MUAP: Area Numeric Values

Record the area in microvolt milliseconds (uVms). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt per millisecond
C12766 Electrophysiology short pre-exercise compound muscle action potential measurement ElctphysShrtPreExercsCMAPMeasr The compound muscle action potential (CMAP) values measured at the pre-exercise intervals The compound muscle action potential (CMAP) values measured at the pre-exercise intervals Pre-Exercise Numeric Values

To be answered for all pre-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12709 Electrophysiology blink reflex test electrode type ElctphysBlnkReflxTstElectrdTyp Type of electrode used for the blink reflex test Type of electrode used for the blink reflex test Recording Electrode Needle;Surface Needle;Surface Alphanumeric

Record the electrode type - choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12742 Electrophysiology neuromuscular jitter pair or endplate study count ElctphyNeurmsJttrPrEndpltStdCt Count of the pairs/endplates studied in the neuromuscular jitter study being described Count of the pairs/endplates studied in the neuromuscular jitter study being described Number of pairs endplates studied Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12721 Electrophysiology repetitive nerve activation technique type ElctphysReptvNervActvtTechnTyp Indicator of the activation technique used in the repetitive nerve study being recorded Indicator of the activation technique used in the repetitive nerve study being recorded Activation Technique Maximum contraction;High frequency stimulation Maximum contraction;High frequency stimulation Alphanumeric

Record the technique used for repetitive stimulation

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12756 Electrophysiology blood pressure response Valsalva phase II early result ElctphysBPRespValslvaPh2ErlRes The blood pressure response to valsalva maneuver during Phase II early The blood pressure response to Valsalva maneuver during Phase II early Blood Pressure Response to Valsalva Maneuver - Phase II early Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

CSV