CDE Detailed Report

Disease: Congenital Muscular Dystrophy
Subdomain Name: Non-Imaging Diagnostics
CRF: Electrophysiology

Displaying 1 - 50 of 88
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C12757 Electrophysiology blood pressure response Valsalva phase II late result ElctphysBPRespValslvPh2LateRes The blood pressure response to valsalva maneuver during Phase II late The blood pressure response to Valsalva maneuver during Phase II late Blood Pressure Response to Valsalva Maneuver - Phase II late Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10778 Electrophysiology motor unit number estimation muscle studied name ElctPhysMUNEMuscleStudiedName Name of the muscle studied using the MUNE (motor unit number estimation) technique Name of the muscle studied using the MUNE (motor unit number estimation) technique Muscle Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12722 Electrophysiology repetitive nerve high frequency ElctphysReptveNervHighFreq Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded If High frequency stimulation specify frequency used Numeric Values

This value is only recorded if High frequency stimulation is answered for Activation Technique. Record the frequency in Hertz (Hz).

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C12768 Electrophysiology short post-exercise compound muscle action potential measurement ElctphyShrtPostExercsCMAPMeasr The compound muscle action potential (CMAP) values measured at the post-exercise intervals The compound muscle action potential (CMAP) values measured at the post-exercise intervals Post-Exercise Numeric Values

To be answered for all post-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12700 Electrophysiology motor nerve dispersion result ElctphysMotrNervDisprsnReslt Amount of test signal dispersion measured during the motor nerve conduction study Amount of test signal dispersion measured during the motor nerve conduction study Dispersed? Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12733 Needle electromyography motor unit action potential complexity percent value NdlElctrmygrpMUAPCompxtyPctVal The complexity of the motor unit action potential measured during needle electromyography The complexity of the action potential measured during needle electromyography MUAP: Complexity Numeric Values

Record the complexity as a percentage (%). Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C12712 Electrophysiology blink reflex test R1 latency value ElctphysBlnkReflxTstR1LatncVal Duration of R1 latency in the blink reflex test Duration of R1 latency in the blink reflex test R one Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12744 Electrophysiology neuromuscular jitter mean consecutive difference abnormal count ElctphysNeurmscJttrMCDAbnrmlCt Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described Number with Abnormal MCD Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12758 Electrophysiology blood pressure response Valsalva phase IV result ElctphysBPRespValslvapPhas4Res The blood pressure response to valsalva maneuver during Phase IV The blood pressure response to Valsalva maneuver during Phase IV Blood Pressure Response to Valsalva Maneuver - Phase IV Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10780 Electrophysiology anatomic site ElctrophysAntmicSite Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed Nerve Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12723 Electrophysiology repetitive nerve activation duration ElctphysReptveNervActvtnDur Duration, in sec, of the activation technique used in the repetitive nerve study being recorded Duration, in sec, of the activation technique used in the repetitive nerve study being recorded Activation Duration Numeric Values

Record the duration of activation in seconds (sec)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

second
C12769 Electrophysiology long pre-exercise compound muscle action potential time ElctphysLngPreExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the long exercise test The time intervals used to measure compound muscle action potential (CMAP) during post-exercise for the long exercise test Pre-Exercise CMAP 3 minutes;CMAP 2 minutes;CMAP 1 minute CMAP 3 minutes;CMAP 2 minutes;CMAP 1 minute Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12701 Electrophysiology motor nerve F-wave minimum latency value ElctphyMotrNervFwavMinLatncVal The length of time needed for the impulse to travel from the site, to the spine, and back to the site measured during the motor nerve conduction study The length of time needed for the impulse to travel from the site, to the spine, and back to the site measured during the motor nerve conduction study F wave minimum latency Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12734 Needle electromyography motor unit action potential stable indicator NdlElctrmygrphyMUAPStablInd The stability of the action potential measure during needle electromyography The stability of the action potential measure during needle electromyography MUAPs: Stable Yes;No Yes;No Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12713 Electrophysiology blink reflex test ipsilateral R2 latency value ElctphysBlnkRefTstIpslR2LatVal Duration of ipsilateral R2 latency in the blink reflex test Duration of ipsilateral R2 latency in the blink reflex test Ipsilateral R two Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12745 Electrophysiology neuromuscular jitter study blocking count ElctphysNeurmscJttrStdyBlockCt Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described Number with Blocking Numeric Values

Record for each muscle tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12759 Electrophysiology quantitative sweat function forearm measurement ElctphyQuantSweatFuncFarmMeasr The amount of sweat collected on the forearm The amount of sweat collected on the forearm Forearm Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10782 Electrophysiology motor unit number estimation method used type ElctphysMUNEMethdUseTyp Type of method or technique used for MUNE (motor unit number estimation) Type of method or technique used for MUNE (motor unit number estimation) Technique Used Incremental;Multipoint;Statistical;Other, specify Incremental;Multipoint;Statistical;Other, specify Alphanumeric

Choose one for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12724 Electrophysiology repetitive nerve postactivation elapsed time duration ElctphyReptvNrvPstacElpsdTmDur Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded Postactivation Time Numeric Values

Record postactivation time in the format hours:minutes:seconds (HH:MM:SS)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C12770 Electrophysiology long pre-exercise compound muscle action potential measurement ElctphysLngPreExercsCMAPMeasr Compound muscle action potential (CMAP) measurement recorded pre- long exercise Compound muscle action potential (CMAP) measurement recorded pre- long exercise Pre-Exercise Numeric Values

To be answered for all pre-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12702 Electrophysiology sensory nerve impulse direction type ElctphysSensryNervImpulsDirTyp The impulse direction put on the nerve during the sensory nerve conduction study The impulse direction put on the nerve during the sensory nerve conduction study Impulse Direction Orthodromic;Antidromic Orthodromic;Antidromic Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12735 Needle electromyography motor unit action potential recruitment type NdlElctrmygrphyMUAPRecrtmntTyp The recruitment of the motor unit action potential measure during needle electromyography The recruitment of the action potential measure during needle electromyography MUAP: Recruitment Normal;Increased/Early;Decreased Normal;Increased/Early;Decreased Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12714 Electrophysiology blink reflex test contralateral R2 latency value ElctphyBlnkReflTstContR2LatVal Duration of contralateral R2 latency in the blink reflex test Duration of contralateral R2 latency in the blink reflex test Contralateral R two Latency Numeric Values

Record the latency in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12746 Electrophysiology fiber density quantitative result value ElctphysFiberDnstyQuantRsltVal Fiber density measured for a particular muscle and side Fiber density measured for a particular muscle and side Fiber Density Numeric Values

Record for each muscle/side tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12760 Electrophysiology quantitative sweat function proximal leg measurement ElctphyQuanSweatFuncPrxLegMeas The amount of sweat collected on the proximal leg The amount of sweat collected on the proximal leg Proximal Leg Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10783 Electrophysiology motor unit number estimation compound muscle action potential measurement ElctphysMUNECMAPMeasr Measurement in millivolts (mV) of the compound muscle action potential (CMAP) amplitude for the muscle on which MUNE (motor unit number estimation) is performed Measurement in millivolts (mV) of the compound muscle action potential (CMAP) amplitude for the muscle on which MUNE (motor unit number estimation) is performed CMAP Numeric Values

Record in microvolts (?V) for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12725 Electrophysiology repetitive nerve postactivation number ElctphysReptveNervPstactvtnNum The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study Postactivation Number Numeric Values

Record the correct number in the series of postactivation timepoints

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12771 Electrophysiology long exercise test post-exercise compound muscle action potential time ElctphysLngPostExercsCMAPTime The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise for the long exercise test The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise for the long exercise test Post-Exercise CMAP immediately;CMAP 1 minute;CMAP 2 minutes;CMAP 3 minutes;CMAP 4 minutes;CMAP 5 minutes;CMAP 6 minutes;CMAP 7 minutes;CMAP 8 minutes;CMAP 9 minutes;CMAP 10 minutes;CMAP 11 minutes;CMAP 12 minutes;CMAP 13 minutes;CMAP 14 minutes;CMAP 15 minutes;CMAP 16 minutes;CMAP 17 minutes;CMAP 18 minutes;CMAP 19 minutes;CMAP 20 minutes;CMAP 21 minutes;CMAP 22 minutes;CMAP 23 minutes;CMAP 24 minutes;CMAP 25 minutes;CMAP 26 minutes;CMAP 27 minutes;CMAP 28 minutes;CMAP 29 minutes;CMAP 30 minutes;CMAP 31 minutes;CMAP 32 minutes;CMAP 33 minutes;CMAP 34 minutes;CMAP 35 minutes;CMAP 36 minutes;CMAP 37 minutes;CMAP 38 minutes;CMAP 39 minutes;CMAP 40 minutes;CMAP 41 minutes;CMAP 42 minutes;CMAP 43 minutes;CMAP 44 minutes;CMAP 45 minutes;CMAP 46 minutes;CMAP 47 minutes;CMAP 48 minutes;CMAP 49 minutes;CMAP 50 minutes;CMAP 51 minutes;CMAP 52 minutes;CMAP 53 minutes;CMAP 54 minutes;CMAP 55 minutes;CMAP 56 minutes;CMAP 57 minutes;CMAP 58 minutes;CMAP 59 minutes;CMAP 60 minutes CMAP immediately;CMAP 1 minute;CMAP 2 minutes;CMAP 3 minutes;CMAP 4 minutes;CMAP 5 minutes;CMAP 6 minutes;CMAP 7 minutes;CMAP 8 minutes;CMAP 9 minutes;CMAP 10 minutes;CMAP 11 minutes;CMAP 12 minutes;CMAP 13 minutes;CMAP 14 minutes;CMAP 15 minutes;CMAP 16 minutes;CMAP 17 minutes;CMAP 18 minutes;CMAP 19 minutes;CMAP 20 minutes;CMAP 21 minutes;CMAP 22 minutes;CMAP 23 minutes;CMAP 24 minutes;CMAP 25 minutes;CMAP 26 minutes;CMAP 27 minutes;CMAP 28 minutes;CMAP 29 minutes;CMAP 30 minutes;CMAP 31 minutes;CMAP 32 minutes;CMAP 33 minutes;CMAP 34 minutes;CMAP 35 minutes;CMAP 36 minutes;CMAP 37 minutes;CMAP 38 minutes;CMAP 39 minutes;CMAP 40 minutes;CMAP 41 minutes;CMAP 42 minutes;CMAP 43 minutes;CMAP 44 minutes;CMAP 45 minutes;CMAP 46 minutes;CMAP 47 minutes;CMAP 48 minutes;CMAP 49 minutes;CMAP 50 minutes;CMAP 51 minutes;CMAP 52 minutes;CMAP 53 minutes;CMAP 54 minutes;CMAP 55 minutes;CMAP 56 minutes;CMAP 57 minutes;CMAP 58 minutes;CMAP 59 minutes;CMAP 60 minutes Alphanumeric

Choose all times at which data were recorded

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C12703 Electrophysiology sensory nerve segment length measurement ElctphysSensNervSegmtLgthMeasr The sensory nerve segment length measured during the sensory nerve conduction study The sensory nerve segment length measured during the sensory nerve conduction study Segment Length Numeric Values

Record the length in centimeters (cm). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

centimeter
C12736 Needle electromyography motor unit action potential activation type NdlElctrmygrphyMUAPActvtnTyp The activation of the motor unit action potential measure during needle electromyography The activation of the action potential measure during needle electromyography MUAP: Activation Normal;Decreased Normal;Decreased Alphanumeric

Answer for both left and right sides of the body. Choose one for each.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12715 Electrophysiology repetitive nerve stimulation study stimulation rate value ElctphysReptNervStimulaRateVal Value, in Hz, of the stimulation rate used in the repetitive nerve study being recorded Value, in Hz, of the stimulation rate used in the repetitive nerve study being recorded Stimulation rate Numeric Values

Record the stimulation rate in Hertz (Hz)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C12747 Electrophysiology motor unit number estimation surface motor unit action potential average value ElctphysMUNEsMUAPAvgVal Average surface motor unit action potentials (sMUAPs), estimated using the designated MUNE (motor unit number estimation) technique Average surface motor unit action potentials (sMUAPs), estimated using the designated MUNE (motor unit number estimation) technique Average sMUAP Numeric Values

Record in microvolts (?V) for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microVolt
C12761 Electrophysiology quantitative sweat function distal leg measurement ElctphyQuanSweatFuncDistLMeasr The amount of sweat collected on the distal leg The amount of sweat collected on the distal leg Distal Leg Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10785 Electrophysiology motor unit number estimation value ElctphysMUNEVal Value of the motor unit number estimate (MUNE), derived by dividing compound muscle action potential (CMAP) amplitude by single motor unit potential (SMUP) amplitude Value of the motor unit number estimate (MUNE), derived by dividing compound muscle action potential (CMAP) amplitude by single motor unit potential (SMUP) amplitude MUNE Numeric Values

Record the calculated MUNE value for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12726 Electrophysiology repetitive nerve postactivation amplitude measurement ElctphyReptNervPstactvAmpMeasr Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded Postactivation Amplitude Numeric Values

Record the amplitude of the response to Postactivation stimulus in millivolts (mV). Record the amplitude for postactivation #1, #n, and 1-n ? for each postactivation timepoint.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12772 Electrophysiology long exercise test post-exercise compound muscle action potential measurement ElctphysLngPostExercsCMAPMeasr Compound muscle action potential (CMAP) measurement recorded post- long exercise Compound muscle action potential (CMAP) measurement recorded post- long exercise Post-Exercise Numeric Values

To be answered for all post-exercise intervals in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12704 Electrophysiology sensory nerve onset or peak latency value ElctphysSensNervOnsPkLatncVal The onset or peak latency measured during the sensory nerve conduction study The onset or peak latency measured during the sensory nerve conduction study Onset or Peak Latency Numeric Values

Record the onset or peak latency in milliseconds (ms). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12737 Needle electromyography interference pattern analysis technique name NdlElctrmygInterfPtrnAnlTchNam The interference pattern technique used for analysis measure during needle electromyography The interference pattern technique used for analysis measure during needle electromyography Interference Pattern Analysis Technique Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12716 Electrophysiology repetitive nerve stimulation study stimulus duration ElctphysReptveNervStimStdyDur Duration, in ?s, of stimulation in the repetitive nerve study being recorded Duration, in ?s, of stimulation in the repetitive nerve study being recorded Stimulus Duration Numeric Values

Record the duration of the stimulus in microseconds (us)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microsecond
C12750 Electrophysiology motor unit number estimation surface motor unit action potential average count ElctphysMUNEsMUAPAvgCt Number of surface motor unit action potentials (sMUAPs) averaged to arrive at the average sMUAP value Number of surface motor unit action potentials (sMUAPs) averaged to arrive at the average sMUAP value Number of sMUAPs averaged Numeric Values

Record for each muscle studied

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12762 Electrophysiology quantitative sweat function foot measurement ElctphysQuantSweatFunctFtMeasr The amount of sweat collected on the foot The amount of sweat collected on the foot Foot Numeric Values

Record the amount of sweat collected in microliters (uL)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

microliter
C10786 Electrophysiology motor unit number estimation nerve type ElctphysMUNENervTyp Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique Nerve Stimulated Axillary;Facial;Femoral;Mandibular;Maxillary;Median;Perineal;Radial;Sciatic;Tibial;Ulnar;Other, specify Axillary;Facial;Femoral;Mandibular;Maxillary;Median;Perineal;Radial;Sciatic;Tibial;Ulnar;Other, specify Alphanumeric

Record the CMAP and SMUP measurements for each nerve and side (right or left)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12727 Electrophysiology repetitive nerve postactivation area measurement ElctphyReptNervPstactAreaMeasr Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded Postactivation Area Numeric Values

Record the amplitude of the response to Postactivation stimulus in millivolts (mV). Record the amplitude for postactivation #1, #n, and 1-n ? for each postactivation timepoint.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt per millisecond
C17969 Electrophysiology sensory nerve segment name ElctphysSensNervSegmntNam The name of the segment used in sensory nerve conduction studies The name of the segment used in motor or sensory nerve conduction studies Segment Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12705 Electrophysiology sensory nerve velocity measurement EltrphysSensryNervVeloctyMeasr The signal transmission speed measured during the sensory nerve conduction study The signal transmission speed measured during the sensory nerve conduction study Velocity (normal limit) Numeric Values

Record the velocity in meters per second (m/s). Record for each segment tested

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

meter per second
C12738 Needle electromyography interference pattern analysis result NdlElctrmygrInterfPttrnAnlyRes The result of the interference pattern analysis measure during needle electromyography The result of the interference pattern analysis measure during needle electromyography Interference Pattern Analysis Result Alphanumeric

Answer for both left and right sides of the body

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12752 Electrophysiology heart rate variability value ElctphysHRVaribltyVal The heart rate variability with deep breathing measured during autonomic function testing The heart rate variability with deep breathing measured during autonomic function testing Heart Rate variability with Deep Breathing Numeric Values

Record the heart rate variability in beats/minute

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 300 beats per minute
C12717 Electrophysiology repetitive nerve stimulation study stimulus intensity value ElctphyReptNervStimStdyIntnVal Value, in mV, of stimulation intensity in the repetitive nerve study being recorded Value, in mV, of stimulation intensity in the repetitive nerve study being recorded Stimulus Intensity Numeric Values

Record the intensity of the stimulus in millivolts (mV)

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations

Free-Form Entry

milliVolt
C12763 Electrophysiology tilt study heart rate change result ElctphysTiltStdyHRChngReslt Heart rate changes experienced from a tilt test Heart rate changes experienced from a tilt test Heart Rate changes Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12693 Electrophysiology H-reflex nerve segment name ElctphysHReflxNervSegmtNam The nerve segment used for the H-reflex test The nerve segment used for the H-reflex test Nerve Segment Alphanumeric

Record the name of the nerve segment used for H-reflex testing

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Electrophysiology Non-Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

CSV