CDE Detailed Report

Disease: Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Spectroscopy (MRS)

Displaying 51 - 56 of 56
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C17939 Scanner manufacturer other name ScannerManufNameOthName Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities Name of the tissue scanner (e.g. Magnetic Resonance Imaging or Computerized Tomography) manufacturer if not one of the listed possibilities Other, specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C10945 Imaging voxel volume measurement ImgVoxelVolMeasr Volume of the voxel calculated by multiplying the three size measurements Volume of the voxel calculated by multiplying the three size measurements Spectroscopy c Geometry iii. Voxel volume: Numeric Values

If this element is answered, then matrix size in plane and z-direction can be left blank. Answer should be recorded in millimeters cubed (mm3)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

cubic millimeter
C17951 Spectroscopy sequence other type text SpectroscopySeqOthTypTxt Text specification of unlisted spectroscopy sequences used in the scan being reported Text specification of unlisted spectroscopy sequence types in the scan being reported Spectroscopy a Sequences used Other specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12163 Spectroscopy water reference data acquire indicator SpectroWaterRefDataAcqInd Indicator whether water reference data was acquired in addition to water suppression acquisition data Indicator whether water reference data was acquired in addition to water suppression acquisition data Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Anatomical Reference Image TR Numeric Values

Answer should be recorded inmilliseconds (ms)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C17940 Spectroscopy geometry voxel slice size anterior posterior value SpectroGeomSizeAntPostVal Value, in mm, of voxel or slice anterior-posterior size for the spectroscopy scan being reported Value, in mm, of voxel or slice anterior-posterior size for the spectroscopy scan being reported Spectroscopy c Geometry ii. Voxel or slice size anterior posterior Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
CSV