CDE Detailed Report

Disease: Neuromuscular Diseases
Subdomain Name: Imaging Diagnostics
CRF: Diffusion Tensor Imaging (DTI)

Displaying 51 - 57 of 57
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10587 Imaging echo spacing value ImgEchoSpcVal Measurement, in milliseconds, of the echo spacing used in diffusion acquisition Measurement, in milliseconds, of the echo spacing used in diffusion acquisitio DTI sequence parameters, Echo spacing Numeric Values

Answer should be recorded in milliseconds (ms). Must be answered with Echo Train Length and number of shots

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10685 Imaging slice orientation type ImgSliceOrientTyp Type of slice orientation used in imaging acquisition Type of slice orientation used in imaging acquisition DTI sequence parameters, Slice orientation: Axial;Coronal;Sagittal;Oblique;Other, specify Axial;Coronal;Sagittal;Oblique;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:40.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) DTI sequence parameters, Slice thickness Numeric Values

Answer should be recorded in millimeters squared (mm)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C17807 Imaging parallel acquisition details text ImgParallAcqstnTxt Text description of any additional details about the parallel acquisition used, if any, in the MRI sequence being reported Text description of any additional details about the parallel acquisition used, if any, in the MRI sequence being reported Additional details Alphanumeric No references available Adult Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C18714 Imaging radio frequency coil channel count other text ImgRFCoilChannelCtOTH The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 2.00 2022-06-29 16:40:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10588 Imaging echo train length measurement ImgEchoTrainLngthMeasr Measurement of the echo train length used in imaging acquisition Measurement of the echo train length used in imaging acquisition DTI sequence parameters, Echo spacing, Echo train length Numeric Values

EPI factor

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10687 Imaging diffusion first b value ImgDiffusionFirstBVal Value, in square millimeters per second, of the first b-value used in diffusion acquisition Value, in square millimeters per second, of the first b-value used in diffusion acquisitio DTI sequence parameters, first b-value Numeric Values

Answer should be recorded in mm2/s

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
CSV