CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10855 Grip strength maximum measurement GripStrengthMaxMeasr Measurement of the maximum grip strength attained in the trial being recorded Measurement of the maximum grip strength attained in the trial being recorded Max Grip Numeric Values

Answer for each hand side in pounds, kilograms or newtons

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430–438. Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Grip Strength Muscle Strength Testing Outcomes and End Points

Free-Form Entry

C10856 Grip strength unit of measure GripStrengthUOM Unit of measure (pounds, kilograms, or newtons) for the maximum grip strength attained or for the target in the trial being recorded Unit of measure (pounds, kilograms, or newtons) for the maximum grip strength attained or for the target in the trial being recorded Indicate units: pounds, kilograms, or newtons lb;kg;N Pounds;Kilograms;Newtons Alphanumeric

Choose one for each grip strength measurement

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430–438. Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Grip Strength Muscle Strength Testing Outcomes and End Points

Single Pre-Defined Value Selected

C00023 Hand preference type HandPrefTyp Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusively Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusivel Handedness Left hand;Right hand;Both hands;Unknown Left hand;Right hand;Both hands;Unknown Alphanumeric

Choose one. The predominant hand does not have to be the hand that he/she writes with. Unknown should be used in the scenario for infants or other (rare) instances when handedness can not be known or is not yet developed.

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430–438. Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Grip Strength Muscle Strength Testing Outcomes and End Points

Single Pre-Defined Value Selected

2180147
C02411 Laterality type LatTyp Laterality type relative to the anatomic site of the body examined or affected Laterality type relative to the anatomic site of the body examined or affected Grip Strength Left;Right Left;Right Alphanumeric

Record the grip strength results for each hand side

Kendall. Muscles: Testing and Function with Posture and Pain, 5th ed. Florence JM, Pandya S, King WM et al. Intrarater reliability of manual muscle test (Medical Research Council Scale) grades in Duchenne's muscular dystrophy. Phys Ther 1992;72:115-126. Adult;Pediatric Exploratory 3.00 2013-08-28 16:08:00.453 Grip Strength Muscle Strength Testing Outcomes and End Points

Single Pre-Defined Value Selected

C10171 Trial number TrialNum The number representing the sequence for any repeated measure test or assessment when it is performed multiple times The number representing the sequence for any repeated measure test or assessment when it is performed multiple times Trial Trial 1;Trial 2 Trial 1;Trial 2 Alphanumeric

It is recommended that two trials be used to measure grip strength

Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. <br /><br />Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. <br /><br />Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. <br /><br />Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430&#8211;438. Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Grip Strength Muscle Strength Testing Outcomes and End Points

Single Pre-Defined Value Selected

C10851 Grip strength test indicator GripStrengthTestInd Indicator whether the grip strength testing was done Indicator whether the grip strength testing was done Was the grip strength testing done? Yes;No Yes;No Alphanumeric

Choose one

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430&#8211;438. Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Grip Strength Muscle Strength Testing Outcomes and End Points

Single Pre-Defined Value Selected

C10852 Grip strength test performed date and time GripStrengthTestPerfDateTime Date (and time, if applicable and known) that grip strength testing was done Date (and time, if applicable and known) that grip strength testing was done Date Performed Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (ISO 8601 - https://www.iso.org/iso-8601-date-and-time-format.html The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430&#8211;438. Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Grip Strength Muscle Strength Testing Outcomes and End Points

Free-Form Entry

C10854 Grip device width setting value GripDeviceWidthSettingVal Value of the width setting on the grip device used to test the participant/subject's grip strength Value of the width setting on the grip device used to test the participant/subject's grip strength Grip Device Width Setting Numeric Values

Record setting on grip strength instrument for each side

Shefner J, Cedarbaum JM, Cudkowicz ME, Maragakis N, Lee J, Jones D, Watson ML, Mahoney K, Chen M, Saikali K, Mao J, Russell AJ, Hansen RL, Malik F, Wolff AA; Neals/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2012;13(5):430&#8211;438. Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Grip Strength Muscle Strength Testing Outcomes and End Points