CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C59054 Imaging quantitative outcome dopamine transporter radioligand type ImgQuanOutDATRadiolgndTyp Type of dopamine transporter (DAT) radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. Type of dopamine transporter (DAT) radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. DAT Ioflupane (SPECT);IACFT (SPECT);β-CIT;CFT (PET) Ioflupane (SPECT);IACFT (SPECT);β-CIT;CFT (PET) Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2022-07-22 11:28:08.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18692 Imaging attenuation correction method type other text ImgAttenuCorrectMethdTypOTH The free-text field related to 'Imaging attenuation correction method type' specifying other text. The type of method to correct for different tissues density when analyzing the image The free-text field related to 'Imaging attenuation correction method type' specifying other text. The type of method to correct for different tissues density when analyzing the image Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 13:58:14.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08253 Imaging visual analysis status ImgVisAnlysisStatus Status of findings from subjective review of image data Status of findings from subjective review of image data Visual Analysis Normal;Abnormal;Other, specify Normal;Abnormal;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-06-28 13:09:35.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59044 Imaging camera type other text ImgCameraTypOTH The free-text field related to 'Imaging camera type', specifying other text. Type of imaging camera used The free-text field related to 'Imaging camera type', specifying other text. Type of imaging camera used Other, specify Alphanumeric

No instructions available.

No references available. Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:13:22.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08266 Imaging post reconstruction filter type ImgPstReconstrctFltrTyp Type of post reconstruction filter used to smooth image data Type of post reconstruction filter used to smooth image data Post Reconstruction Filter Butterworth;Lowpass Butterworth;Lowpass Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59055 Imaging quantitative outcome vesicular monoamine transporter 2 radioligand type ImgQuanOutVMAT2RadiolgndTyp Type of vesicular monoamine transporter 2 (VMAT2) radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. Type of vesicular monoamine transporter 2 (VMAT2) radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. VMAT2 AV133;DTBZ AV133;DTBZ Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2022-07-22 11:31:51.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18698 Imaging F-dopa binding ratio type other text ImgFdopaBindRatTypOTH The free-text field related to 'Imaging F-dopa binding ratio type' specifying other text. Type of F-dopa binding ratio with respect to the rest of the brain The free-text field related to 'Imaging F-dopa binding ratio type' specifying other text. Type of F-dopa binding ratio with respect to the rest of the brain Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 2.00 2022-07-22 16:20:47.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08254 Imaging visual analysis location performed type ImgVisAnlysisLocPerfTyp Type of location where visual analysis of the imaging data are performed Type of location where visual analysis of the imaging data are performed Where visual analysis was performed Central;Other, specify;Local - Site Central;Other, specify;Local - Site Alphanumeric

Choose one

No references available Adult Supplemental-Highly Recommended 3.10 2022-07-22 15:18:03.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18720 Imaging visual analysis location performed type other text ImgVisAnlysisLocPerfTypOTH The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed Other, specify Alphanumeric

Choose one

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 15:20:37.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59045 Imaging pre-scan procedure type carbidopa specify text ImgPrescnProcdrTypCarbSpcfyTxt The free-text field related to 'Imaging pre-scan procedure type', specifying Carbidopa details. Type(s) of pre-scan procedures administered to the participant/subject The free-text field related to 'Imaging pre-scan procedure type', specifying Carbidopa details. Type(s) of pre-scan procedures administered to the participant/subject Carbidopa, specify Alphanumeric

No instructions available.

No references available. Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:15:18.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08267 Imaging outcome variable name ImgOutcomeVarName Name of the primary imaging outcome variable Unit of measure used to specify the length of time medication(s) were withheld from the subject pre-treatment for the imaging scan Imaging Outcome Volume of interest;Voxel based;Other, specify Volume of interest;Voxel based;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59056 Imaging quantitative outcome tyrosine hydroxylase radioligand type ImgQuanOutTyrHydRadiolgndTyp Type of tyrosine hydroxylase radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. Type of tyrosine hydroxylase radioligand used for the quantitative imaging outcome to describe tracer distribution and uptake for the imaging data analysis being documented. Tyrosine Hydroxylase Fluoro-metatyrosine (FMT) Fluoro-metatyrosine (FMT) Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2022-07-22 11:37:33.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C01541 Weight measurement WgtMeasr Measurement of participant's weight Measurement of participant's weight Current Body Weight Numeric Values

Record the weight of the participant/subject in kilograms (kg). To be collected at the visit, not self-reported.

No references available Adult Supplemental-Highly Recommended 3.10 2024-02-29 15:49:21.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 500 kilogram 2179689
C18699 Imaging isotope type other text ImgIsotopeTypOTH The free-text field related to 'Imaging isotope type' specifying other text. Type of radioactive isotope used for the imaging scan The free-text field related to 'Imaging isotope type' specifying other text. Type of radioactive isotope used for the imaging scan Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-21 15:39:03.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08255 Imaging visual analysis blinded indicator ImgVisAnlysisBlindInd Indicator of whether the visual analysis was performed blinded to clinical data Indicator of whether the visual analysis was performed blinded to clinical data Was the visual analysis performed blinded to clinical data? Yes;No;Unknown Yes;No;Unknown Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-25 08:54:08.2 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18721 Imaging visual analysis status other text ImgVisAnlysisStatOTH The free-text field related to 'Imaging visual analysis status' specifying other text. Status of findings from subjective review of image data The free-text field related to 'Imaging visual analysis status' specifying other text. Status of findings from subjective review of image data Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 15:16:46.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59046 Imaging observe method status ImgObserveMethdStat Status related to the method of observation of participant/subject during scan Status related to the method of observation of participant/subject during scan Status of participant during scan Directly observed;Movements recorded Directly observed;Movements recorded Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:24:43.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08268 Imaging volume of interest placement method type ImgVOIPlacementMthdTyp Type of method used for volume of interest (VOI) placement for the imaging data analysis Type of method used for volume of interest (VOI) placement for the imaging data analysis Method for VOI placement Automated;Subjective Placement;Other, specify Automated;Subjective Placement;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59057 Imaging amyloid centiloid anatomic site ImgAmyloidCentiloidAnatSite Anatomic site(s) for which quantitative estimations of amyloid plaque obtained by imaging were recorded using, or were scaled to, the Centiloid scale. Anatomic site(s) for which quantitative estimations of amyloid plaque obtained by imaging were recorded using, or were scaled to, the Centiloid scale. Amyloid Imaging Centiloids Neocortex;Posterior cingual/precuneus;Frontal;Parietal;Lateral;Temporal;Mesiotemporal;Anterior cingulate;Striatum;Cerebellar gray;Whole cerebellum;Other, specify Neocortex;Posterior cingual/precuneus;Frontal;Parietal;Lateral;Temporal;Mesiotemporal;Anterior cingulate;Striatum;Cerebellar gray;Whole cerebellum;Other, specify Alphanumeric

No instructions available

Klunk WE, Koeppe RA, Price JC, Benzinger TL, Devous MD Sr, Jagust WJ, Johnson KA, Mathis CA, Minhas D, Pontecorvo MJ, Rowe CC, Skovronsky DM, Mintun MA. The Centiloid Project: standardizing quantitative amyloid plaque estimation by PET. Alzheimers Dement. 2015 Jan;11(1):1-15.e1-4. doi: 10.1016/j.jalz.2014.07.003. Epub 2014 Oct 28. PMID: 25443857; PMCID: PMC4300247. Adult Supplemental 1.00 2022-07-22 11:40:19.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C02014 Medication prior or concomitant name MedctnPriorConcomName Name of the prior/concomitant agent or drug administered Name of the prior/concomitant agent or drug administere Parkinson's Disease (PD) Medication Alphanumeric

Only answer if 'Yes' is answered for 'PD medications'

No references available Adult Supplemental-Highly Recommended 3.00 2013-08-28 16:08:00.453 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

3162728
C18700 Imaging matrix size value other text ImgMatrixSizeValOTH The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-01 16:00:38.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 50

Free-Form Entry

C08258 Imaging radioligand type ImgRadiolgndTyp Isotope-labeled bioactive compound (generic or common name) used in the imaging scan Isotope-labeled bioactive compound (generic or common name) used in the imaging scan Radioligand Ioflupane;IACFT;β-CIT;FDG;Florbetapir;Florbetaben;PIB;DOPA;MIBG;Fluoro-metatyrosine (FMT);DTBZ, specify;Other, specify Ioflupane;IACFT;β-CIT;FDG;Florbetapir;Florbetaben;PIB;DOPA;MIBG;Fluoro-metatyrosine (FMT);DTBZ, specify;Other, specify Alphanumeric

Choose only one

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18722 Imaging volume of interest anatomic location type other text ImgVOIAntmicLocTypOTH The free-text field related to 'Imaging volume of interest anatomic location type' specifying other text. Type of anatomic location used for volume of interest (VOI) for the imaging data analysis The free-text field related to 'Imaging volume of interest anatomic location type' specifying other text. Type of anatomic location used for volume of interest (VOI) for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 15:43:35.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59047 Imaging scatter correction indicator ImgScatterCorrectInd Indicator of whether imaging scatter correction was used Indicator of whether imaging scatter correction was used Scatter Correction No;Yes No;Yes Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:32:24.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08269 Imaging volume of interest anatomic location type ImgVOIAntmicLocTyp Type of anatomic location used for volume of interest (VOI) for the imaging data analysis Type of anatomic location used for volume of interest (VOI) for the imaging data analysis VOI Locations Striatum;Cortex;Other, specify Striatum;Cortex;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59058 Imaging amyloid centiloid anatomic site other text ImgAmyloidCentiloidAnatSiteOTH The free-text field related to 'Imaging amyloid centiloid anatomic site' specifying other text. The free-text field related to 'Imaging amyloid centiloid anatomic site' specifying other text. Other, specify Alphanumeric

No instructions available

Klunk WE, Koeppe RA, Price JC, Benzinger TL, Devous MD Sr, Jagust WJ, Johnson KA, Mathis CA, Minhas D, Pontecorvo MJ, Rowe CC, Skovronsky DM, Mintun MA. The Centiloid Project: standardizing quantitative amyloid plaque estimation by PET. Alzheimers Dement. 2015 Jan;11(1):1-15.e1-4. doi: 10.1016/j.jalz.2014.07.003. Epub 2014 Oct 28. PMID: 25443857; PMCID: PMC4300247. Adult Supplemental 1.00 2022-07-22 11:45:11.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Scanner (Include Model and Manufacturer) GE;Siemens;Philips;Other, specify GE;Siemens;Philips;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 4.00 2024-03-18 15:21:17.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18702 Imaging outcome variable name other text ImgOutcomeVarNameOTH The free-text field related to 'Imaging outcome variable name' specifying other text. Name of the primary imaging outcome variable The free-text field related to 'Imaging outcome variable name' specifying other text. Name of the primary imaging outcome variable Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 15:40:01.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08259 Imaging radioligand specific activity value ImgRadiolgndSpcfcActVal Value of the specific activity of the Radioligand in Bq/Kg Value of the specific activity of the Radioligand in Bq/Kg Specific activity of radioligand (Bq/kg) Numeric Values

if the activity is unknown, enter or check "Not known"

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 10000 Becquerel per kilogram
C18723 Imaging volume of interest placement method type other text ImgVOIPlacementMthdTypOTH The free-text field related to 'Imaging volume of interest placement method type' specifying other text. Type of method used for volume of interest (VOI) placement for the imaging data analysis The free-text field related to 'Imaging volume of interest placement method type' specifying other text. Type of method used for volume of interest (VOI) placement for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 15:41:53.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59048 Imaging deadtime correction indicator ImgDeadtimeCorrectInd Indicator of whether imaging deadtime correction was used Indicator of whether imaging deadtime correction was used Deadtime Correction No;Yes No;Yes Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:34:00.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08270 Imaging reference region text ImgRefRegnTxt Text that describes the reference region used for the imaging scan and analysis Text that describes the reference region used for the imaging scan and analysis Reference Region Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Camera Software Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-24 11:38:01.2 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18705 Imaging post injection management type other text ImgPstInjMgtTypOTH The free-text field related to 'Imaging post injection management type' specifying other text. The type of special management post injection prior to image acquisition The free-text field related to 'Imaging post injection management type' specifying other text. The type of special management post injection prior to image acquisition Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-22 13:55:09.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C20247 Imaging scanner model name text ImgScannerModelNameTxt The free-text field related to name of model of imaging scanner The free-text field related to the name of the imaging scanner Model Alphanumeric

No instructions available.

No references available. Adult Supplemental-Highly Recommended 1.10 2024-03-18 15:21:17.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08260 Imaging isotope type ImgIsotopeTyp Type of radioactive isotope used for the imaging scan Type of radioactive isotope used for the imaging scan Isotope 123-I;18-F;11-C;99 Tcm;Other, specify 123-I;18-F;11-C;99 Tcm;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59049 Imaging randoms correction indicator ImgRandomCorrectInd Indicator of whether imaging randoms correction was used Indicator of whether imaging randoms correction was used Randoms Correction No;Yes No;Yes Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:36:17.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08271 Imaging quantitative outcome type ImgQuantOutcmeTyp Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis If YES, indicate type Amyloid Imaging Binding Potential;Amyloid Imaging Centiloids;Amyloid Imaging Mean Cortical Binding Potential;Amyloid Imaging Standardized Uptake Value (SUV);Amyloid Imaging Volume of Distribution;DAT;FDopa;Other, specify;Tyrosine Hydroxylase;VMAT2;Scan aborted Amyloid Imaging Binding Potential;Amyloid Imaging Centiloids;Amyloid Imaging Mean Cortical Binding Potential;Amyloid Imaging Standardized Uptake Value (SUV);Amyloid Imaging Volume of Distribution;DAT;FDopa;Other, specify;Tyrosine Hydroxylase;VMAT2;Scan aborted Alphanumeric

If YES to Imaging quantitative outcome indicator, indicate type

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes Duration of the imaging scan in minutes Duration of Scan (minutes) Numeric Values

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-24 11:38:01.2 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C18707 Imaging pre-scan procedure type other text ImgPrescnProcdrTypOTH The free-text field related to 'Imaging pre-scan procedure type' specifying other text. Type(s) of pre-scan procedures administered to the participant/subject The free-text field related to 'Imaging pre-scan procedure type' specifying other text. Type(s) of pre-scan procedures administered to the participant/subject Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 2.00 2022-07-21 16:20:44.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59036 Imaging scan initiation time ImgScanInitiationTime Time of scan initiation Time of scan initiation Time of Scan Initiation Date or Date & Time

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-01 16:51:19.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C08261 Imaging radioligand dose value ImgRadiolgndDosVal Dose of injected radioligand for the imaging scan Dose of injected radioligand for the imaging scan Dose Numeric Values

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-08-28 16:08:00.453 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C59050 Imaging reconstruct image resolution full width half maximum millimeter value ImgRecImgResFWHMMmVal Value in millimeters of the reconstructed image resolution measured as full width at half maximum (FWHM) Value in millimeters of the reconstructed image resolution measured as full width at half maximum (FWHM) Reconstructed Image Resolution (FWHM) Numeric Values

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-21 16:38:19.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C08272 Imaging F-dopa binding ratio type ImgFdopaBindRatTyp Type of F-dopa binding ratio with respect to the rest of the brain Type of F-dopa binding ratio with respect to the rest of the brain Fdopa Striatal (Regional);Putamen;Caudate;Other, specify Striatal (Regional);Putamen;Caudate;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08243 Imaging matrix size value ImgMatrixSizeVal Value representing the imaging matrix size in millimeters Value representing the imaging matrix size in millimeters Image Matrix Size 64 x 64;128 x 128;512 x 512;Other, specify 64 x 64;128 x 128;512 x 512;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

millimeter
C18709 Imaging quantitative outcome type other text ImgQuantOutcmeTypOTH The free-text field related to 'Imaging quantitative outcome type' specifying other text. Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis The free-text field related to 'Imaging quantitative outcome type' specifying other text. Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 2.00 2022-07-22 16:22:28.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C59037 Medication Parkinsons disease indicator MedctnParkinsnDzInd Indicator of whether participant/subject is taking medication for Parkinson's disease Indicator of whether participant/subject is taking medication for Parkinson's disease PD Medications Yes;No Yes;No Alphanumeric

If YES, list the last dose of PD medications.

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-01 16:53:04.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08262 Imaging radioligand dose unit of measure ImgRadiolgndDoseUoM Unit of measure for the dose of injected radioligand for the imaging scan Unit of measure for the dose of injected radioligand for the imaging scan Unit of Measure mCi;Mbq;Other, specify mCi;Mbq;Other, specify Alphanumeric

Choose one

No references available Adult Supplemental-Highly Recommended 3.00 2013-07-22 09:34:41.527 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C59051 Imaging MRI acquire co-registration indicator ImgMRIAcqCoRegInd Indicator of whether MRI was acquired for co-registration with the imaging study being documented. Indicator of whether MRI was acquired for co-registration with the imaging study being documented. MRI Acquired for Co-registration No;Yes No;Yes Alphanumeric

No instructions available

No references available Adult Supplemental-Highly Recommended 1.00 2022-07-22 11:17:34.0 PET-SPECT Localization Imaging Diagnostics Assessments and Examinations