CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Vessel Imaging Transcranial
Displaying 1 - 50 of 74
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C14002 | Extracranial stenosis collateral artery anatomic site | ExtracranStenCollArtAntmicSite | The site of parallel arteries having extracranial stenosis | The site of parallel arteries having extracranial stenosi | Collateral | OA;ACA;VA | Ophthalmic artery;Anterior cerebral artery;Vertebral artery | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18693 | Imaging contrast agent method other text | ImgContrastAgentMethodOTH | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained | Date (and time, if applicable and known) the radiologic study was obtained | Date of MRI | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:51:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14014 | Intracranial stenosis other criteria result | IntracranStenoOthCriteriaReslt | Other criteria for intracranial stenosis | Other criteria for intracranial stenosis | Other | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13941 | Imaging insonation plane type | ImgInsonPlaneTyp | Indicates insonation plane | Indicates insonation plane | Insonation plane | Free;Coronal;Axial mesencephalic | Free;Coronal;Axial mesencephalic | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14032 | Vasospasm severity grade | VasospasmSeverGrade | Indicates severity of vasospasm | Indicates severity of vasospasm | Severity | Mild;Moderate;Severe | Mild;Moderate;Severe | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13952 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - score | COGIFScore | The score related to the consensus on grading intracranial flow obstruction (COGIF) | The score related to the consensus on grading intracranial flow obstruction (COGIF) | COGIF score | No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion | No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14003 | Imaging brain death present indicator | ImgBrainDeathPresInd | Indicates presence of brain death | Indicates presence of brain death | Brain Death | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18900 | Intracranial stenosis collateral vessel anatomic other text | IntracrnStnoColltVsslAntmicOTH | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator of whether an imaging contrast agent was used for the scan | Indicator as to whether or not an imaging contrast agent was used for the scan | Contrast Agent | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14015 | High intensity transient signal hits count | HighIntensTransSignalHitsCt | Numeric value counting the number of high intensity transient signals hits | Numeric value counting the number of high intensity transient signals hits | Number | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | ||||||||
C13942 | Imaging vessel category | ImgVesselCat | Indicates vessel category | Indicates vessel category | Vessels | M1;Insular M2;A1;ICA;P1;P2;EC ICA;Vertebral;Basilar | M1;Insular M2;A1;Internal Carotid Artery (ICA);P1;P2;EC Internal Carotid Artery (ICA);Vertebral;Basilar | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14033 | Vasospasm vessel anatomic site | VasospasmVesselAntmicSite | Indicates vasospasm vessel(s) | Indicates vasospasm vessel(s) | Vessel(s) | ICA;Basilar;MCA;VA | Internal carotid artery;Basilar;Middle cerebral artery;Vertebral artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13953 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up indicator | COGIFFollowupInd | Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up | Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up | COGIF Follow-up | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14005 | Imaging brain death diagnosis result | ImgBrainDeathDiagReslt | Indicates brain death diagnosis result | Indicates brain death diagnosis result | Brain Death | Reversed Diastolic Flow;Systolic spike;No signals | Reversed Diastolic Flow;Systolic spike;No signals | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18901 | Sickle cell disease vessel anatomic other text | SickleCellDisVesselAntmicOTH | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | Other, specify | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13750 | Imaging study ID number | ImgStudyIDNum | Unique identification number assigned to the study or assessment session | Unique identification number assigned to the study or assessment sessio | Study ID number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14016 | High intensity transient signal hits start time | HighIntensTransSigHitStartTime | Indicates high intensity transient signal hits start time | Indicates high intensity transient signal hits start time | Start Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13943 | Imaging B-mode result | ImgBModReslt | Indicates B mode | Indicates B mode | B mode | Normal;Occlusion;Stenosis | Normal;Occlusion;Stenosis | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13954 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up date and time | COGIFFollowupDateTime | The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-up | The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-u | Date, Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14034 | Vasomotor response (VMR) vessel anatomic site | VMRVesselAntmicSite | Indicates vasomotor response (VMR) vessel type | Indicates vasomotor response (VMR) vessel type | Vessel | MCA;Other, specify | Middle cerebral artery;Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14006 | Imaging stenosis percentage value | ImgStenosisPercentageVal | Indicates stenosis percentage value | Indicates stenosis percentage value | Percent Stenosis | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 99 | percent | |||||||
C18903 | Vasomotor response (VMR) vessel anatomic other text | VMRVesselAntmicOTH | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Initial;Monitoring | Initial;Monitoring | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14020 | Sickle cell disease vessel anatomic site | SickleCellDisVesselAntmicSite | Indicates sickle cell vessel | Indicates sickle cell vessel | Vessel(s) | MCA;Other, specify | Middle cerebral artery;Other, specify | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13944 | Imaging color flow indicator | ImgColorFlowInd | Indicates color flow | Indicates color flow | Color flow | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13955 | Imaging transcranial color-coded sonography symptomatic indicator | ImgTCCSSymptomaticInd | Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) | Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) | Symptomatic | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14035 | VMR response result | VMRResponseReslt | Indicates vasomotor response (VMR) response result | Indicates vasomotor response (VMR) response result | VMR | Abnormal;Normal | Abnormal;Normal | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14007 | Imaging Transcranial Doppler (TCD) findings result type | ImgTCDFindResltTyp | Indicates Transcranial Doppler (TCD) findings | Indicates Transcranial Doppler (TCD) findings | Findings | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Alphanumeric |
Select all that apply. Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C58867 | Imaging chronic stroke type | ImgChronStrkStudTyp | Indicates chronic stroke type | Indicates chronic stroke type | Chronic Stroke | Hemisphere;Eye;Vetebrobasilar | Hemisphere;Eye;Vetebrobasilar | Alphanumeric |
Indicate the type of chronic stroke |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-18 11:12:20.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13899 | Imaging probe type text | ImgProbeTypTxt | The text describing the type of imaging probe | Describes imaging probe type | Type | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14021 | Sickle cell disease blood flow velocity measurement | SickleCellVelBldFlowMeasr | The velocity measurement blood flow relative to sickle cell disease | The velocity measurement blood flow relative to sickle cell diseas | Velocity | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C13945 | Imaging spectrum depth measurement | ImgSpectrumDepthMeasr | Indicates spectrum depth measurement (mm) | Indicates spectrum depth measurement (mm) | Depth | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter | |||||||
C13956 | High intensity transient signal hits duration | HighIntensTransSignalHitsDur | Indicates high intensity transient signal hits duration time (msec) | Indicates high intensity transient signal hits duration time (msec) | Duration time | Numeric Values |
Indicate duration time in units of msec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millisecond | |||||||
C14036 | Breath-holding index result | BreathHoldingIndexReslt | Indicates Breath-holding index (BHI) result | Indicates breath-holding index (BHI) result | Breath-holding index (BHI) | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14008 | Imaging window quality category | ImgWindowQualityCat | Indicates window quality category | Indicates window quality category | Insonation window | Temporal;Posterior;Orbital | Temporal;Posterior;Orbital | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C58868 | Imaging transient ischemic attack type | ImgTIATyp | Indicates type of transient ischemic attack | Indicates type of transient ischemic attack | TIA | Hemisphere;Eye;Vetebrobasilar | Hemisphere;Eye;Vetebrobasilar | Alphanumeric |
Indicate the type of TIA |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-18 11:20:04.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13900 | Imaging probe frequency | ImgProbeFreq | Indicates imaging probe frequency (Hz) | Indicates imaging probe frequency (Hz) | Frequency | Numeric Values |
Indicate frequency in units of Hz |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz | |||||||||
C14023 | Sickle cell disease diagnosis result | SickleCellDiagnosReslt | Indicates sickle cell diagnosis result | Indicates sickle cell diagnosis result | Sickle Cell (indication for study) | Abnormal;Normal;Conditional | Abnormal;Normal;Conditional | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13946 | Imaging spectrum angle correction indicator | ImgSpectrumAngleCorrectionInd | Indicates spectrum angle correction | Indicates spectrum angle correction | Angle correction | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13957 | High intensity transient signal hits intensity value | HighIntensTransSignalHitsVal | Indicates high intensity transient signal hits intensity value (dB) | Indicates high intensity transient signal hits intensity value (dB) | Intensity | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
decibel | |||||||||
C14037 | Imaging power M mode left middle cerebral artery result type | ImgPowerMModeLeftMCAResTyp | Indicates power M mode for left middle cerebral artery (MCA) result | Indicates power M mode for left middle cerebral artery (MCA) result | Left MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:28:20.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14009 | Imaging window quality result | ImgWindowQualityReslt | Indicates window quality result for all categories | Indicates window quality result for all categories | Window quality | Fair;Excellent;Poor | Fair;Excellent;Poor | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; and Flow direction) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C58905 | Imaging transcranial ultrasound performed type | ImgTranscrnUltrsndPerfmdTyp | Indicates the ultrasound type | Indicates the ultrasound type | Ultrasound Type | Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) | Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) | Alphanumeric |
Indicate ultrasound type |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-19 14:23:40.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13901 | Imaging patient type | ImgPatientTyp | Indicates imaging patient type | Indicates imaging patient type | Patient type | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14024 | Vasospasm criterion value | VasoCriterionVal | Indicates vasospasm criterion value | Indicates vasospasm criterion value | Criterion | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13947 | Imaging peak velocity measurement | ImgPeakVelocityMeasr | Indicates peak velocity measurement (cm/sec) | Indicates peak velocity measurement (cm/sec) | Peak velocity | Numeric Values |
Indicate peak velocity in units of cm/sec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C13960 | High intensity transient signal hits vessel anatomic site | HighIntensTransSigHitAnatSite | Indicates high intensity transient signal hits vessel category | Indicates high intensity transient signal hits vessel category | High intensity transient signal hits | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14038 | Imaging power M mode right middle cerebral artery result type | ImgPowerMModeRightMCAResTyp | Indicates power M mode for right middle cerebral artery (MCA) result | Indicates power M mode for right middle cerebral artery (MCA) result | Right MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:52:18.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14010 | Intracranial stenosis collateral vessel anatomic site | IntracrnStnoColltVsslAntmicSit | Indicates intracranial stenosis collateral vessel(s) | Indicates intracranial stenosis collateral vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;VA | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Vertebral artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |