CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C58905 | Imaging transcranial ultrasound performed type | ImgTranscrnUltrsndPerfmdTyp | Indicates the ultrasound type | Indicates the ultrasound type | Ultrasound Type | Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) | Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) | Alphanumeric |
Indicate ultrasound type |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-19 14:23:40.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13901 | Imaging patient type | ImgPatientTyp | Indicates imaging patient type | Indicates imaging patient type | Patient type | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14009 | Imaging window quality result | ImgWindowQualityReslt | Indicates window quality result for all categories | Indicates window quality result for all categories | Window quality | Fair;Excellent;Poor | Fair;Excellent;Poor | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; and Flow direction) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13947 | Imaging peak velocity measurement | ImgPeakVelocityMeasr | Indicates peak velocity measurement (cm/sec) | Indicates peak velocity measurement (cm/sec) | Peak velocity | Numeric Values |
Indicate peak velocity in units of cm/sec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C14024 | Vasospasm criterion value | VasoCriterionVal | Indicates vasospasm criterion value | Indicates vasospasm criterion value | Criterion | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13960 | High intensity transient signal hits vessel anatomic site | HighIntensTransSigHitAnatSite | Indicates high intensity transient signal hits vessel category | Indicates high intensity transient signal hits vessel category | High intensity transient signal hits | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14038 | Imaging power M mode right middle cerebral artery result type | ImgPowerMModeRightMCAResTyp | Indicates power M mode for right middle cerebral artery (MCA) result | Indicates power M mode for right middle cerebral artery (MCA) result | Right MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:52:18.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C58906 | Vasospasm resistive index value | VasospasmRestistIndexVal | Indicates vasospasm resistive Index (RI) | Indicates vasospasm resistive Index (RI) | Resistive index | Numeric Values |
(RI) These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-19 17:46:31.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13902 | Imaging acute stroke study type | ImgAcutStokStudTyp | Indicates imaging acute stroke study type | Indicates imaging acute stroke study type | Indicate study type | Initial;Follow-up 1;Follow-up 2 | Initial;Follow-up 1;Follow-up 2 | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14010 | Intracranial stenosis collateral vessel anatomic site | IntracrnStnoColltVsslAntmicSit | Indicates intracranial stenosis collateral vessel(s) | Indicates intracranial stenosis collateral vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;VA | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Vertebral artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13948 | Imaging mean blood velocity measurement | ImgMeanBloodVelocityMeasr | Indicates mean velocity measurement (cm/sec) of blood | Indicates mean velocity measurement (cm/sec) of blood | Mean velocity | Numeric Values |
Indicate mean velocity in units of cm/sec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C14025 | Vasospasm Lindegaard ratio value | VasoLinegaardRatioVal | Indicates vasospasm lindegaard ratio result | Indicates vasospasm Lindegaard ratio result | Lindegaard ratio | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13961 | High intensity transient signal hits present indicator | HighIntensTransSigHitPresInd | Indicates presence of high intensity transient signals hits | Indicates presence of high intensity transient signals hits | High intensity transient signal hits | Yes;No | Yes;No | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14051 | High intensity transient signal hits end time | HighIntensTransSigHitEndTime | Indicates high intensity transient signal hits end time | Indicates high intensity transient signal hits end time | End Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13903 | Imaging interpretation site location | ImgInterpretSiteLoc | Indicates imaging interpretation site | Indicates imaging interpretation site | Interpretation site | Onsite;Offsite | Onsite;Offsite | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14011 | Intracranial stenosis present indicator | IntracranStenosisPresentInd | Indicates presence of intracranial stenosis | Indicates presence of intracranial stenosis | Intracranial stenosis | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13949 | Imaging flow/probe direction type | ImgFlowProbDireTyp | Indicates flow/probe direction | Indicates flow/probe direction | Direction of Probe | Towards;Away from | Towards;Away from | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14026 | Intracranial pressure imaging result | ICPReslt | Indicates intracranial pressure (ICP) imaging result | Indicates vasospasm intracranial pressure (ICP) imaging result | Intracranial pressure | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter of mercury | |||||||
C01559 | Arterial partial pressure carbon dioxide value | ArterialPPCO2Val | Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) | Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) | Partial pressure of carbon dioxide (PCO2) | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-20 10:21:25.65 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 100 | millimeter of mercury | |||||||
C14000 | Extracranial stenosis present indicator | ExtracranStenPresInd | Indicates presence of extracranial stenosis | Indicates presence of extracranial stenosis | Extracranial stenosis | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14052 | Hemoglobin measurement | HemoglobMeasr | The measurement for hemoglobin | The measurement for hemoglobi | Hemoglobin | Numeric Values |
Contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13904 | Imaging interpretation offsite media type | ImgInterpretOffsiteMediaTyp | Indicates imaging offsite media type | Indicates imaging offsite media type | Indicate type | Video;Print;Digital | Video;Print;Digital | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14012 | Intracranial stenosis peak systolic velocity (PSV) criterion result | IntracranStenoPSVCriterReslt | Indicates intracranial stenosis peak systolic velocity (PSV) criterion | Indicates intracranial stenosis peak systolic velocity (PSV) criterion | Peak Systolic Velocity (PSV) criterion | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13950 | Imaging spectrum asymmetry index result | ImgSpectrumAsymmetryIndexReslt | Indicates spectrum asymmetry index result | Indicates spectrum asymmetry index result | Asymmetry index | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14028 | Vasospasm present indicator | VasoPresInd | Indicates presence of vasospasm | Indicates presence of vasospasm | Vasospasm | Yes;No | Yes;No | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02411 | Laterality type | LatTyp | Laterality type relative to the anatomic site of the body examined or affected | Laterality type relative to the anatomic site of the body examined or affected | Laterality | Left;Right | Left;Right | Alphanumeric |
Select only one |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-08-28 16:08:00.453 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14001 | Extracranial stenosis type | ExtracranStenosisTyp | Indicates extracranial stenosis type | Indicates extracranial stenosis type | Extracranial stenosis | Collateral;Reduced upstroke;Reduced pulsatility index (Pi);VMR;Reduced velocity | Collateral;Reduced upstroke;Reduced pulsatility index (Pi);VMR;Reduced velocity | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14056 | Imaging depth measurement | ImgDepthMeasr | The depth measurement (mm) of imaging | The depth measurement (mm) of imagin | Depth | Numeric Values |
"These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies" |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter | |||||||
C13905 | Imaging contrast agent method type | ImgContrastAgentMethodTyp | Indicates imaging contrast agent method of administration | Indicates imaging contrast agent method of administratio | Type | Bolus;Infusion;Other, specify | Bolus;Infusion;Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14013 | Intracranial stenosis mean velocity criterion value | IntracranStenoMnVlctyCriterVal | Indicates intracranial stenosis mean velocity criterion | Indicates intracranial stenosis mean velocity criterion | Mean velocity criterion | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13951 | Imaging spectrum end diastolic ratio value | ImgSpectrumEndDiastlRatioVal | Indicates spectrum end diastolic ratio result | Indicates spectrum end diastolic ratio result | End diastolic ratio | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14029 | Vasospasm posterior ratio result | VasoPosterRatioReslt | Indicates vasospasm posterior ratio result | Indicates vasospasm posterior ratio result | Posterior ratio | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 10 | ||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained | Date (and time, if applicable and known) the radiologic study was obtained | Date of MRI | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:51:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14002 | Extracranial stenosis collateral artery anatomic site | ExtracranStenCollArtAntmicSite | The site of parallel arteries having extracranial stenosis | The site of parallel arteries having extracranial stenosi | Collateral | OA;ACA;VA | Ophthalmic artery;Anterior cerebral artery;Vertebral artery | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18693 | Imaging contrast agent method other text | ImgContrastAgentMethodOTH | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13941 | Imaging insonation plane type | ImgInsonPlaneTyp | Indicates insonation plane | Indicates insonation plane | Insonation plane | Free;Coronal;Axial mesencephalic | Free;Coronal;Axial mesencephalic | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14014 | Intracranial stenosis other criteria result | IntracranStenoOthCriteriaReslt | Other criteria for intracranial stenosis | Other criteria for intracranial stenosis | Other | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13952 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - score | COGIFScore | The score related to the consensus on grading intracranial flow obstruction (COGIF) | The score related to the consensus on grading intracranial flow obstruction (COGIF) | COGIF score | No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion | No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14032 | Vasospasm severity grade | VasospasmSeverGrade | Indicates severity of vasospasm | Indicates severity of vasospasm | Severity | Mild;Moderate;Severe | Mild;Moderate;Severe | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator of whether an imaging contrast agent was used for the scan | Indicator as to whether or not an imaging contrast agent was used for the scan | Contrast Agent | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14003 | Imaging brain death present indicator | ImgBrainDeathPresInd | Indicates presence of brain death | Indicates presence of brain death | Brain Death | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18900 | Intracranial stenosis collateral vessel anatomic other text | IntracrnStnoColltVsslAntmicOTH | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13942 | Imaging vessel category | ImgVesselCat | Indicates vessel category | Indicates vessel category | Vessels | M1;Insular M2;A1;ICA;P1;P2;EC ICA;Vertebral;Basilar | M1;Insular M2;A1;Internal Carotid Artery (ICA);P1;P2;EC Internal Carotid Artery (ICA);Vertebral;Basilar | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14015 | High intensity transient signal hits count | HighIntensTransSignalHitsCt | Numeric value counting the number of high intensity transient signals hits | Numeric value counting the number of high intensity transient signals hits | Number | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | ||||||||
C13953 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up indicator | COGIFFollowupInd | Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up | Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up | COGIF Follow-up | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14033 | Vasospasm vessel anatomic site | VasospasmVesselAntmicSite | Indicates vasospasm vessel(s) | Indicates vasospasm vessel(s) | Vessel(s) | ICA;Basilar;MCA;VA | Internal carotid artery;Basilar;Middle cerebral artery;Vertebral artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13750 | Imaging study ID number | ImgStudyIDNum | Unique identification number assigned to the study or assessment session | Unique identification number assigned to the study or assessment sessio | Study ID number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14005 | Imaging brain death diagnosis result | ImgBrainDeathDiagReslt | Indicates brain death diagnosis result | Indicates brain death diagnosis result | Brain Death | Reversed Diastolic Flow;Systolic spike;No signals | Reversed Diastolic Flow;Systolic spike;No signals | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18901 | Sickle cell disease vessel anatomic other text | SickleCellDisVesselAntmicOTH | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | Other, specify | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13943 | Imaging B-mode result | ImgBModReslt | Indicates B mode | Indicates B mode | B mode | Normal;Occlusion;Stenosis | Normal;Occlusion;Stenosis | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |