CDE Detailed Report

Disease: Stroke
Subdomain Name: Imaging Diagnostics
CRF: Vessel Imaging Transcranial

Displaying 51 - 74 of 74
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C14002 Extracranial stenosis collateral artery anatomic site ExtracranStenCollArtAntmicSite The site of parallel arteries having extracranial stenosis The site of parallel arteries having extracranial stenosi Collateral OA;ACA;VA Ophthalmic artery;Anterior cerebral artery;Vertebral artery Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18693 Imaging contrast agent method other text ImgContrastAgentMethodOTH The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration Other, specify Alphanumeric

Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter)

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02494 Imaging study date and time ImgStdyDateTime Date (and time, if applicable and known) the radiologic study was obtained Date (and time, if applicable and known) the radiologic study was obtained Date of MRI Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] Adult;Pediatric Supplemental 3.10 2024-02-29 15:51:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C14014 Intracranial stenosis other criteria result IntracranStenoOthCriteriaReslt Other criteria for intracranial stenosis Other criteria for intracranial stenosis Other Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C13941 Imaging insonation plane type ImgInsonPlaneTyp Indicates insonation plane Indicates insonation plane Insonation plane Free;Coronal;Axial mesencephalic Free;Coronal;Axial mesencephalic Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13952 Consensus on Grading Intracranial Flow Obstruction (COGIF) - score COGIFScore The score related to the consensus on grading intracranial flow obstruction (COGIF) The score related to the consensus on grading intracranial flow obstruction (COGIF) COGIF score No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion No flow;Low flow/No diastolic flow;Low flow/diastolic flow;Established perfusion Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14032 Vasospasm severity grade VasospasmSeverGrade Indicates severity of vasospasm Indicates severity of vasospasm Severity Mild;Moderate;Severe Mild;Moderate;Severe Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14003 Imaging brain death present indicator ImgBrainDeathPresInd Indicates presence of brain death Indicates presence of brain death Brain Death Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18900 Intracranial stenosis collateral vessel anatomic other text IntracrnStnoColltVsslAntmicOTH The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator of whether an imaging contrast agent was used for the scan Indicator as to whether or not an imaging contrast agent was used for the scan Contrast Agent Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14015 High intensity transient signal hits count HighIntensTransSignalHitsCt Numeric value counting the number of high intensity transient signals hits Numeric value counting the number of high intensity transient signals hits Number Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999
C13942 Imaging vessel category ImgVesselCat Indicates vessel category Indicates vessel category Vessels M1;Insular M2;A1;ICA;P1;P2;EC ICA;Vertebral;Basilar M1;Insular M2;A1;Internal Carotid Artery (ICA);P1;P2;EC Internal Carotid Artery (ICA);Vertebral;Basilar Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C13953 Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up indicator COGIFFollowupInd Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up COGIF Follow-up Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14033 Vasospasm vessel anatomic site VasospasmVesselAntmicSite Indicates vasospasm vessel(s) Indicates vasospasm vessel(s) Vessel(s) ICA;Basilar;MCA;VA Internal carotid artery;Basilar;Middle cerebral artery;Vertebral artery Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14005 Imaging brain death diagnosis result ImgBrainDeathDiagReslt Indicates brain death diagnosis result Indicates brain death diagnosis result Brain Death Reversed Diastolic Flow;Systolic spike;No signals Reversed Diastolic Flow;Systolic spike;No signals Alphanumeric

Select all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18901 Sickle cell disease vessel anatomic other text SickleCellDisVesselAntmicOTH The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel Other, specify Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C13750 Imaging study ID number ImgStudyIDNum Unique identification number assigned to the study or assessment session Unique identification number assigned to the study or assessment sessio Study ID number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C14016 High intensity transient signal hits start time HighIntensTransSigHitStartTime Indicates high intensity transient signal hits start time Indicates high intensity transient signal hits start time Start Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13943 Imaging B-mode result ImgBModReslt Indicates B mode Indicates B mode B mode Normal;Occlusion;Stenosis Normal;Occlusion;Stenosis Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13954 Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up date and time COGIFFollowupDateTime The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-up The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-u Date, Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C14034 Vasomotor response (VMR) vessel anatomic site VMRVesselAntmicSite Indicates vasomotor response (VMR) vessel type Indicates vasomotor response (VMR) vessel type Vessel MCA;Other, specify Middle cerebral artery;Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14006 Imaging stenosis percentage value ImgStenosisPercentageVal Indicates stenosis percentage value Indicates stenosis percentage value Percent Stenosis Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 percent
C18903 Vasomotor response (VMR) vessel anatomic other text VMRVesselAntmicOTH The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C13751 Imaging acquisition reason ImgAcquisitionRsn Describes why the imaging study was performed Describes why the imaging study was performed Scan purpose Initial;Monitoring Initial;Monitoring Alphanumeric

Select all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

CSV