CDE Detailed Report
Subdomain Name: [php]
CRF: welcome
Displaying 1 - 27 of 27
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C08254 | Imaging visual analysis location performed type | ImgVisAnlysisLocPerfTyp | Type of location where visual analysis of the imaging data are performed | Type of location where visual analysis of the imaging data are performed | Read type | Central;Central read;Local - Site;Local read;Local report;Other, specify | Central;Central read;Local - Site;Local read;Local report;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2022-07-22 15:18:03.0 | Perfusion Imaging | [php] | [php_1] |
Multiple Pre-Defined Values Selected |
||||||||
C13873 | Imaging perfusion computed tomography based identification perfusion defect volume type | ImgPCTBaseIDPerDefVolTyp | Indicates CT (PCT) based identification of perfusion defect volume type | Indicates CT (PCT) based identification of perfusion defect volume type | Volume Type | Mean transit time lesion volume;Time to peak lesion volume;Cerebral blood volume(CBV) defect volume;Time-to-max (Tmax) lesion volume | Mean transit time lesion volume;Time to peak lesion volume;Cerebral blood volume(CBV) defect volume;Time-to-max (Tmax) lesion volume | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Multiple Pre-Defined Values Selected |
|||||||||
C58679 | Imaging perfusion computed tomography based identification perfusion defect threshold value | ImgPCTBaseIDPerDefThVal | Value of PCT based identification of perfusion defect threshold used to delineate abnormality | Value of PCT based identification of perfusion defect threshold used to delineate abnormality | Threshold value for identification of abnormality | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2020-01-10 14:46:11.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
||||||||||||
C08255 | Imaging visual analysis blinded indicator | ImgVisAnlysisBlindInd | Indicator of whether the visual analysis was performed blinded to clinical data | Indicator of whether the visual analysis was performed blinded to clinical data | Reader blinded to clinical data | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C13874 | Imaging perfusion computed tomography based identification perfusion defect threshold type | ImgPCTBaseIDPerDefThTyp | Indicates PCT based identification of perfusion defect threshold type used to delineate abnormality | Indicates PCT based identification of perfusion defect threshold type used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C10931 | Imaging quality technically satisfactory status | ImgQualTechnSatisStat | Status related to whether the quality of the images was technically satisfactory | Status related to whether the quality of the images was technically satisfactory | Study technically satisfactory | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:51.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C13875 | Imaging perfusion computed tomography based identification perfusion defect value | ImgPCTBaseIDPerDefVal | Value of PCT based identification of perfusion defect abnormality | Value of PCT based identification of perfusion defect abnormality | Value of abnormality | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
|||||||||||
C13750 | Imaging study ID number | ImgStudyIDNum | Unique identification number assigned to the study or assessment session | Unique identification number assigned to the study or assessment sessio | Study ID number | Alphanumeric | No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] | 255 |
Free-Form Entry |
||||||||||
C13876 | Imaging perfusion computed tomography based identification perfusion defect volume measurement | ImgPCTBaseIDPerDefVolMeasr | Indicates PCT based identification of perfusion defect volume | Indicates PCT based identification of perfusion defect volume | Defect volume | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
0 | 999 | milliliter | ||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Diagnostic;Post-treatment;Monitoring;Other, specify | Diagnostic;Post-treatment;Monitoring;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Multiple Pre-Defined Values Selected |
||||||||
C18701 | Imaging modality type other text | ImgModltyTypOTH | The free-text field related to 'Imaging modality type', specifying other text. Type of radiologic study performed on the participant | The free-text field related to 'Imaging modality type', specifying other text. Type of radiologic study performed on the participant | Other, specify | Alphanumeric |
Select all that apply |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] Haacke, E.M., Duhaime, A.C., Gean, A.D., Riedy, G., Wintermark, M., Mukherjee, P., Brody, D.L., DeGraba, T., Duncan, T.D., and Elovic, E. (2010). Common data elements in radiologic imaging of traumatic brain injury. Journal of Magnetic Resonance Imaging 32, 516-543, DOI:10.1002/jmri.22259 | Adult;Pediatric | Supplemental | 1.10 | 2024-02-29 15:53:08.0 | Perfusion Imaging | [php] | [php_1] | 4000 |
Free-Form Entry |
|||||||||
C13861 | Imaging magnetic resonance based identification perfusion defect method type | ImgMRBasedIDPerfusnDefMethTyp | Indicates MR based identification of perfusion defect - method used for perfusion processing | Indicates MR based identification of perfusion defect - method used for perfusion processing | Method used for perfusion processing | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C18718 | Imaging scanner strength value type other text | ImgScannerStrgthValTypOTH | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Record the MRI scanner strength in Tesla (T) |
No references available | Adult;Pediatric | Supplemental | 2.10 | 2024-03-18 15:21:17.0 | Perfusion Imaging | [php] | [php_1] | 4000 |
Free-Form Entry |
|||||||||
C13862 | Imaging magnetic resonance based identification perfusion defect volume type | ImgMRBasedIDPerfusnDefVolTyp | Indicates MR based identification of perfusion defect volume type | Indicates MR based identification of perfusion defect volume type | Volume Type | Cerebral blood flow (CBV) defect volume;Mean transit time lesion volume;Time to peak lesion volume;Time to maximum (Tmax) lesion volume | Cerebral blood flow (CBV) defect volume;Mean transit time lesion volume;Time to peak lesion volume;Time to maximum (Tmax) lesion volume | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Multiple Pre-Defined Values Selected |
|||||||||
C18720 | Imaging visual analysis location performed type other text | ImgVisAnlysisLocPerfTypOTH | The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed | The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed | Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-22 15:20:37.0 | Perfusion Imaging | [php] | [php_1] | 4000 |
Free-Form Entry |
|||||||||
C02437 | Imaging modality type | ImgModltyTyp | Type of radiologic study performed on the participant | Type of radiologic study performed on the participant | Imaging modality | Non-contrast CT;Contrast CT;CT Angiography;X-Ray Angiography;MRI;MR Angiography;Post-contrast CT;Contrast MRI;Non-contrast MRI;PET;SPECT;MEG;CT Perfusion;MRI Perfusion;OCT;Microscopy;DEXA;EEG;Ultrasound;Other, specify;Cone Beam Computed Tomography (CBCT) | Non-contrast CT;Contrast CT;CT Angiography;X-Ray Angiography;MRI;MR Angiography;Post-contrast CT;Contrast MRI;Non-contrast MRI;PET;SPECT;MEG;CT Perfusion;MRI Perfusion;OCT;Microscopy;DEXA;EEG;Ultrasound;Other, specify;Cone Beam Computed Tomography (CBCT) | Alphanumeric |
Select all that apply |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] Haacke, E.M., Duhaime, A.C., Gean, A.D., Riedy, G., Wintermark, M., Mukherjee, P., Brody, D.L., DeGraba, T., Duncan, T.D., and Elovic, E. (2010). Common data elements in radiologic imaging of traumatic brain injury. Journal of Magnetic Resonance Imaging 32, 516-543, DOI:10.1002/jmri.22259 | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:08.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
||||||||
C13863 | Imaging magnetic resonance based identification perfusion defect threshold type | ImgMRBsdIDPerfusnDefThrshldTyp | Indicates MR based identification of perfusion defect threshold type used to delineate abnormality | Indicates MR based identification of perfusion defect threshold type used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C18888 | Imaging acquisition reason other text | ImgAcquisitionRsnOTH | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] | 4000 |
Free-Form Entry |
|||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained | Date (and time, if applicable and known) the radiologic study was obtained | Date and time of study | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:51:00.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
||||||||||
C13864 | Imaging magnetic resonance based identification perfusion defect value | ImgMRBasedIDPerfusnDefVal | Value of MR based identification of perfusion defect abnormality | Value of MR based identification of perfusion defect abnormality | Value of abnormality | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
|||||||||||
C58633 | Imaging CT slice count | ImgCTSliceCt | Count representing the total number of single image planes captured during computed tomography (CT) imaging acquisition | Count representing the total number of single image planes captured during computed tomography (CT) imaging acquisitio | Number of slices | 64;128;320;256 | 64;128;320;256 | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2019-03-18 12:35:06.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
||||||||||
C02495 | Imaging scanner strength value type | ImgScannerStrgthValTyp | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify | 1.5T;3.0T;4.0T;7.0T;Other, specify | Alphanumeric |
Record the MRI scanner strength in Tesla (T) |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:31.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
||||||||
C13865 | Imaging magnetic resonance based identification perfusion defect volume measurement | ImgMRBasedIDPerfusnDefVolMeasr | Indicates MR based identification of perfusion defect volume | Indicates MR based identification of perfusion defect volume | Defect volume | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
0 | 999 | milliliter | ||||||||
C58634 | Imaging CT slice count other text | ImgCTSliceCountOthrTxt | The free-text field related to 'Imaging CT slice count' specifying other text | The free-text field related to 'Imaging CT slice count' specifying other tex | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental | 1.00 | 2019-03-18 16:10:45.0 | Perfusion Imaging | [php] | [php_1] | 255 |
Free-Form Entry |
|||||||||||
C08244 | Imaging slice thickness value | ImgSliceThicknessVal | Value of the thickness of the slice measured in millimeters (mm) | Value of the thickness of the slice measured in millimeters (mm) | Slice thickness | Numeric Values |
Record the MRI slice thickness in millimeters (mm) |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |
0 | 99 | millimeter | |||||||
C13872 | Imaging perfusion computed tomography based identification perfusion defect correction method type | ImgPCTBaseIDPerDefCorMethdTyp | Indicates PCT based identification of perfusion defect method used for perfusion processing | Indicates PCT based identification of perfusion defect correction method used for perfusion processing | Method used for perfusion processing | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion Imaging | [php] | [php_1] |
Single Pre-Defined Value Selected |
|||||||||
C58678 | Imaging magnetic resonance based identification perfusion defect threshold value | ImgMRBsdIDPerfusnDefThrshldVal | Value of MR based identification of perfusion defect threshold used to delineate abnormality | Value of MR based identification of perfusion defect threshold used to delineate abnormality | Threshold value for identification of abnormality | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2020-01-10 14:46:11.0 | Perfusion Imaging | [php] | [php_1] |
Free-Form Entry |