CDE Detailed Report

Disease: Myalgic Encephalomyelitis/Chronic Fatigue Syndrome
Subdomain Name: Imaging Diagnostics
CRF: Low Resolution Electromagnetic Tomography (LORETA)

Displaying 1 - 25 of 25
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C58383 Imaging interest region voxel select method type ImgIntrstRegnVoxlSlctMethdTyp Type of method used to select the voxels related to the region of interest Type of method used to select the voxels related to the region of interest Voxels: MNI coordinates used to define significantly active regions;Single Nearest Voxel method;All-Voxels-Within-A-Radius MNI coordinates used to define significantly active regions;Single Nearest Voxel method (each region of interest has a single voxel);All-Voxels-Within-A-Radius Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-08 13:33:05.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C54780 EEG samping rate category EEGSamplingRateCategory Category of sampling rate for the EEG Category of sampling rate for the EEG Sampling rate: 256 Hz;512 Hz;Other, specify;1024 Hertz;128 Hertz 256 Hertz;512 Hertz;Other, specify;1024 Hertz;128 Hertz Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-04-12 10:53:05.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58160 Windowing function other taper percent overlap value WndwFuncOthTaprPctOvrlpVal Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using other taper windowing function Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using other taper windowing function Other taper window function (% overlap) Numeric Values Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:21:39.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 100 Percent
C58139 Quantitative EEG electrode other count qEEGElectrodeOtherCt The free-value field related to "Quantitative EEG electrode count category" specifying other count The free-value field related to 'Quantitative EEG electrode count category' specifying other count Number of electrodes (from qEEG data, min 19 electrodes): Numeric Values Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 09:00:49.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C58161 Windowing function Hanning Hamming percent overlap value WndwFuncHanHamPctOvrlpVal Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using Hanning (Hamming) windowing function Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using Hanning (Hamming) windowing function Hanning (Hamming) window function (% overlap) Numeric Values Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:24:28.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 100 Percent
C58142 Imaging comparison data source type ImgComparisonDataSourceTyp Type of data source for comparison with study imagery Type of data source for comparison with study imagery Comparison parameters Controls;Normative database Controls;Normative database Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 09:13:12.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58162 Low resolution electromagnetic tomography frequency band category LORETAFreqBandCat Category of frequency bands used for low resolution electromagnetic tomography (LORETA) Category of frequency bands used for low resolution electromagnetic tomography (LORETA) Define frequency bands as follows within LORETA Conventional band settings;Researcher-defined bands Conventional band settings: delta = 1-3 Hertz, theta = 4-7 Hertz, alpha = 8-12 Hertz, beta-1 = 13-18 Hertz, beta-2 = 19-21 Hertz, beta-3 = 22-30 Hertz, omega = 1-30 Hertz;Researcher-defined bands, e.g., 1 Hertz, 2 Hertz, 3 Hertz, etcetera Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:27:21.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58143 Imaging comparison data source name ImgComparisonDataSourceName Name of data source used for comparison with study imagery Name of data source used for comparison with study imagery If database used, name database Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 09:13:12.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C58164 Low resolution electromagnetic tomography researcher defined frequency band type LORETARsrchrDefFrqBndTyp Type, meaning frequencies in Hertz, of researcher-defined bands used for low resolution electromagnetic tomography (LORETA) Type, meaning frequencies in Hertz, of researcher-defined bands used for low resolution electromagnetic tomography (LORETA) Researcher-defined bands, such as 1 Hz bands--1 Hz, 2 Hz, 3 Hz, etc. (name bands) Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:48:32.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C58153 Software low resolution electromagnetic tomography analysis name SftwrLORETAAnlysName Name of the software used for low resolution electromagnetic tomography (LORETA) analysis Name of the software used for low resolution electromagnetic tomography (LORETA) analysis Software for analysis: LORETA-KEY software;swLORETA;Other LORETA-KEY software (LORETA, sLORETA, eLORETA);swLORETA;Other Alphanumeric

LORETA-KEY software available at www.uzh.ch/keyinst/loreta.htm. swLORETA now available at www.appliedneuroscience.com

Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 10:51:56.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58165 Montreal Neurological Institute average brain map use electrode placement indicator MNIAvgBrnMapUsElctrdPlcmtInd Indicator of whether the Montreal Neurological Institute (MNI) average brain map was used for electrode placement Indicator of whether the Montreal Neurological Institute (MNI) average brain map was used for electrode placement Electrode coordinates: head model of eLORETA & electrode coordinates are based on the Montreal Institute average MNI brain map (MNI 152) No;Yes No;Yes Alphanumeric Mazziotta J, Toga A, Evans A, Fox P, Lancaster J, Zilles K, Woods R, Paus T, Simpson G, Pike B, Holmes C, Collins L, Thompson P, MacDonald D, Iacoboni M, Schormann T, Amunts K, Palomero-Gallagher N, Geyer S, Parsons L, Narr K, Kabani N, Le Goualher G, Feidler J, Smith K, Boomsma D, Hulshoff Pol H, Cannon T, Kawashima R, Mazoyer B. A four-dimensional probabilistic atlas of the human brain. J Am Med Inform Assoc. 2001;8(5):401-430. PMID: 11522763 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:52:03.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58154 Brain volume qualitative analysis category BrnVolQualAnalysCat Category of the brain volume analysed, in qualitative terms Category of the brain volume analysed, in qualitative terms Full brain volume / Partial brain volume Full brain volume;Partial brain volume Full brain volume;Partial brain volume Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 10:57:46.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58166 Electrode placement head system type ElctrodPlacmntSystmHeadTyp Type of system used for electrode placement on the head Type of system used for electrode placement on the head Use of: 10/20 system;Other system 10/20 system;Other system (define) Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:57:22.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58155 Software low resolution electromagnetic tomography analysis name other text SftwrLORETAAnlysNameOthTxt The free-text field related to 'Software low resolution electromagnetic tomography analysis name' specifying the name of other software used for low resolution electromagnetic tomography (LORETA) analysis The free-text field related to 'Software low resolution electromagnetic tomography analysis name' specifying the name of other software used for low resolution electromagnetic tomography (LORETA) analysis Other: Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 10:51:56.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C58167 Electrode placement head system other text ElctrodPlacmntSystmHeadOthTxt The free-text field related to 'Electrode placement head system type' for specifying the type of system used for electrode placement on the head The free-text field related to 'Electrode placement head system type' for specifying the type of system used for electrode placement on the head Other system (define) Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:57:22.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C58156 Brain part text BrainPartTxt Text describing the part of the brain examined if less than the full brain volume Text describing the part of the brain examined if less than the full brain volume Partial brain volume (portion to be examined if using other source analysis software) Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:03:13.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C58168 State analysis method type StateAnalysisMethodTyp Type of method used for state analysis Type of method used for state analysis State analysis type: Current density power time series;Current density power XYZ time series;Instantaneous linear connectivity;Instantaneous nonlinear connectivity;Lagged linear connectivity;Lagged nonlinear connectivity;Total linear connectivity;Total nonlinear connectivity;Instantaneous coherence;Isolated effective coherence;Lagged coherence;Total coherence;Instantaneous phase synchronization;Lagged phase synchronization;Total phase synchronization;Microstate segmentation;Global connectivity;Independent component analysis;Cross frequency analysis;Other Current density power time series;Current density power XYZ time series;Instantaneous linear connectivity;Instantaneous nonlinear connectivity;Lagged linear connectivity;Lagged nonlinear connectivity;Total linear connectivity;Total nonlinear connectivity;Instantaneous coherence;Isolated effective coherence;Lagged coherence;Total coherence;Instantaneous phase synchronization;Lagged phase synchronization;Total phase synchronization;Microstate segmentation;Global connectivity;Independent component analysis;Cross frequency analysis;Other Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 12:05:26.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C13970 Brain region of interest type BrainROITyp Region of interest in the brain Region of interest in the brain Specify ROIs (regions of interest) within solution space Frontal;Parietal;Temporal;Occipital;White matter;Basal ganglia;Pons;Brain stem;Unknown;Other, specify Frontal;Parietal;Temporal;Occipital;White matter;Basal ganglia;Pons;Brain stem;Unknown;Other, specify Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 3.00 2013-08-28 16:08:00.453 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58157 Qualitative EEG time series data type qEEGTimeSeriesDataTyp Type of time series data exported from qualitative EEG (qEEG) Type of time series data exported from qualitative EEG (qEEG) Exported time series from qEEG data 2-second EEG segments windowing function;EEG artifact-free data with > .90 reliability estimates 2-second EEG segments windowing function (to control for spectral leakage);EEG artifact-free data with > .90 reliability estimates Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:07:16.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58169 State analysis method other text StateAnalysisMethdOthTxt The free-text field related to 'State analysis method type' specifying other text The free-text field related to 'State analysis method type' specifying other text Other: Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 12:13:00.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C17438 EEG sampling rate EEGSamplingRate Electroencephalography (EEG) sampling rate, commonly recorded in Hz (250-2000 Hz) Electroencephalography (EEG) sampling rate, commonly recorded in Hz (250-2000 Hz) specify Other: Numeric Values Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 3.00 2013-08-28 16:08:00.453 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C58158 Data time series 2 second EEG windowing function type DatTimSer2SecEEGWndwFunTyp Type of 2-second EEG segment windowing function time-series data exported Type of 2-second EEG segment windowing function time-series data exported 2-second EEG segments windowing function Cosine taper window function;Hanning (Hamming) window function;Non-overlapping (successive) window function;Other taper window function Cosine taper window function;Hanning (Hamming) window function;Non-overlapping (successive) window function;Other taper window function Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:11:53.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58170 MATLAB script name MatlabScriptName Name(s) of MATLAB script(s) used Name(s) of MATLAB script(s) used MATLAB scripts used: Alphanumeric Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 12:16:08.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C18895 Brain region of interest other text BrainROIOTH The free-text field related to 'Brain region of interest type' specifying other text. Region of interest in the brain The free-text field related to 'Brain region of interest type' specifying other text. Region of interest in the brain Other, specify: Alphanumeric

Specify ROIs (regions of interest) within solution space

Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 3.00 2013-08-28 16:08:00.453 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C58159 Windowing function cosine taper percent value WindowFuncCosTaprPctVal Value, as a percentage, of 2-second EEG segments produced for time-series analysis using cosine taper windowing function Value, as a percentage, of 2-second EEG segments produced for time-series analysis using cosine taper windowing function % cosine taper window Numeric Values Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography<br />neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397. <br /><br />Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.<br /><br />Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081 Adult;Pediatric Supplemental-Highly Recommended 1.00 2018-02-05 11:19:02.0 Low Resolution Electromagnetic Tomography (LORETA) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 100 Percent
CSV