CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Quantitative Electroencephalography (qEEG)
Displaying 1 - 45 of 45
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C00007 | Birth date | BirthDate | Date (and time, if applicable and known) the participant was born | Date (and time, if applicable and known) the participant was born | Birthdate: | Date or Date & Time | Adult;Pediatric | Supplemental-Highly Recommended | 3.1 | 10/16/2024 8:51:14 AM | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
793 | |||||||||||
C58138 | Quantitative EEG electrode count category | qEEGElectrodeCntCat | Category of the count of electrodes placed for quantitative EEG (qEEG) | Category of the count of electrodes placed for quantitative EEG (qEEG) | Electrode placement: | 19 channels;Other | 19 channels (minimal for research);Other | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 08:56:06.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C14551 | EEG behavioral state recorded type | EEGBehavioralStateRecordedTyp | The recorded state(s) of the subject during the electroencephalogram (EEG) | The recorded state(s) of the subject during the Electroencephalography (EEG) | Behavioral state of participant: | Awake;Asleep;Other, specify;Drowsy;Unresponsive state | Awake;Asleep;Other, specify;Drowsy;Unresponsive state | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||||
C58149 | EEG record observation qualitative type | EEGRecObservtnQualtatvTyp | Type of qualitative observations of the EEG record | Type of qualitative observations of the EEG record | Observations of EEG record? | Drowsiness;Excessive spiking;Epileptiform activity;Other | Drowsiness;Excessive spiking;Epileptiform activity;Other | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:42:41.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||||
C56160 | Technician name | TechName | The name of the technician that is overseeing the test | The name of the technician that is overseeing the tes | Technician: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-07 14:01:45.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C00008 | Age value | AgeVal | Value for participant's age, calculated as elapsed time since the birth of the participant | Value for participant's age, calculated as elapsed time since the birth of the participant | Age: | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:47:28.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 1800 | month | |||||||||
C58139 | Quantitative EEG electrode other count | qEEGElectrodeOtherCt | The free-value field related to "Quantitative EEG electrode count category" specifying other count | The free-value field related to 'Quantitative EEG electrode count category' specifying other count | Specify number of electrodes over 19: | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:00:49.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||||
C15626 | Imaging nonstimulation eye assessment indicator | ImgNonstimEyeAssmtInd | Participant's/subject's eyes status | Participant's/subject's eyes indicator | Recording condition | Eyes Open;Eyes Closed | Eyes Open;Eyes Closed | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C58150 | EEG record observation qualitative other text | EEGRecObsrvatnQualttvOthTxt | The free-text field related to 'EEG record observation qualitative type' for specifying other observations | The free-text field related to 'EEG record observation qualitative type' for specifying other observations | Other observations: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:46:23.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C58125 | Imaging amplifier calibration last 6 month indicator | ImgAmplfrCalLst6MoInd | Indicator of whether the amplifier used in the imaging assessment was calibrated in the last 6 months | Indicator of whether the amplifier used in the imaging assessment was calibrated in the last 6 months | Amplfier calibrated for this study or in past 6 months? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-02 15:26:37.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C00023 | Hand preference type | HandPrefTyp | Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusively | Hand which the participant/subject uses predominantly, not necessarily the hand he/she writes with exclusivel | Handedness: | Left hand;Right hand;Both hands | Left hand;Right hand;Both hands | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
2180147 | |||||||||
C58140 | Quantitative EEG montage method source | qEEGMontagMethodSource | Source of the method used to produce the quantitative EEG (qEEG) montage | Source of the method used to produce the quantitative EEG (qEEG) montage | Montage: | Laplacian;Average reference;Common reference;Linked ears;Nicolet;NovaTech;Deymed;Deymed 19;Deymed 22;Bipolar;Cadwell;Discovery;Discovery 19;Fistar;Mitsar;Nihon Kohden;NeuroField;NeXus21;NeuronSpectrum;Mindset;Other | Laplacian;Average reference;Common reference;Linked ears;Nicolet;NovaTech;Deymed;Deymed 19;Deymed 22;Bipolar;Cadwell;Discovery;Discovery 19;Fistar;Mitsar;Nihon Kohden;NeuroField;NeXus21;NeuronSpectrum;Mindset;Other | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:08:14.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C17425 | EEG duration | EEGDuration | The length of time for the Electroencephalography (EEG) | The length of time for the Electroencephalography (EEG) | qEEG recording time: | Other, specify:;5 Minutes;8 Minutes | Other, specify:;5 Minutes;8 Minutes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C58126 | Imaging amplifier name | ImgAmplifierName | Name (model/make/other) of the imaging amplifier used | Name (model/make/other) of the imaging amplifier used | State amplifier name: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-02 15:31:24.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C00035 | Gender type | GenderTyp | Self-reported gender of the participant/subject | Self-reported gender of the participant/subjec | Sex: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
2200604 | |||||||||||
C58141 | Quantitative EEG montage method other text | qEEGMontagMethodOthTxt | The free-text field related to 'Quantitative EEG montage method source' describing the method used to produce the quantitative EEG (qEEG) montage | The free-text field related to 'Quantitative EEG montage method source' describing the method used to produce the quantitative EEG (qEEG) montage | Other: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:08:14.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C17438 | EEG sampling rate | EEGSamplingRate | Electroencephalography (EEG) sampling rate, commonly recorded in Hz (250-2000 Hz) | Electroencephalography (EEG) sampling rate, commonly recorded in Hz (250-2000 Hz) specify | Other: | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||||
C58127 | Electrode wet dry type | ElectrodeWetDryTyp | Type (wet or dry) of electrode used | Type (wet or dry) of electrode use | Electrode choices: | Dry;Wet | Dry (not for research due to high impedances);Wet | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-02 15:39:55.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C01522 | Height measurement | HgtMeasr | Measurement of participant's height | Measurement of participant's height | Height: | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:49:20.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 400 | centimeter | 649 | ||||||||
C58142 | Imaging comparison data source type | ImgComparisonDataSourceTyp | Type of data source for comparison with study imagery | Type of data source for comparison with study imagery | Comparison parameters: | Controls;Normative database | Controls;Normative database | Alphanumeric |
Normative Databases are vital to patient evaluation and science. For example, normative databases are typically used in blood tests, nerve conduction studies, ocular and retinal studies, and are integral to MRI, Fmri and PET. All of these dabases meet a set of statistical and scientific standards, including peer-reviewed publications, discoosure of inclusion/exclusion criteria, age range, number of samples per age group, SES status, statistical tests of validity, reliability and cross-validation, adequate sample sizes, etc. It is therefore recommended that the electroencephalographer use a validated normative database. Following is a list of gold standards by which to judge a QEEG normative database: Amplifier matching, peer-reviewed publications, artifact rejection, test-retest reliability, inclusion/exclusion criteria, sample size by age group (check for adequacy), approximation to a normal curve, cross validation, clinical correlation, FDA-registered. |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:13:12.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C18045 | Post reconstruction filter other text | PstReconstrctFltrOthrTxt | Specify in text the type of post reconstruction filter other than listed above used to smooth image data | Specify in text the type of post reconstruction filter other than listed above used to smooth image data | Other | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-20 10:46:24.96 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C58128 | Imaging referral reason | ImgReferralRsn | Reason for the imaging referral | Reason for the imaging referral | Reason(s) for referral? | Clinical;Other;Research | Clinical;Other;Research | Alphanumeric |
Select all that apply |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-02 15:58:44.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
|||||||||
C01541 | Weight measurement | WgtMeasr | Measurement of participant's weight | Measurement of participant's weight | Weight: | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:49:21.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 500 | kilogram | 2179689 | ||||||||
C58143 | Imaging comparison data source name | ImgComparisonDataSourceName | Name of data source used for comparison with study imagery | Name of data source used for comparison with study imagery | If database used, name database: | Alphanumeric |
Normative Databases are vital to patient evaluation and science. For example, normative databases are typically used in blood tests, nerve conduction studies, ocular and retinal studies, and are integral to MRI, Fmri and PET. All of these dabases meet a set of statistical and scientific standards, including peer-reviewed publications, discoosure of inclusion/exclusion criteria, age range, number of samples per age group, SES status, statistical tests of validity, reliability and cross-validation, adequate sample sizes, etc. It is therefore recommended that the electroencephalographer use a validated normative database. Following is a list of gold standards by which to judge a QEEG normative database: Amplifier matching, peer-reviewed publications, artifact rejection, test-retest reliability, inclusion/exclusion criteria, sample size by age group (check for adequacy), approximation to a normal curve, cross validation, clinical correlation, FDA-registered. |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:13:12.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C18964 | EEG location other text | EEGLocOTH | The free-text field related to 'EEG location type' specifying other text. The location of where the electroencephalogram (EEG) took place | The free-text field related to 'EEG location type' specifying other text. The location of where the electroencephalogram (EEG) took place | Other (specify): | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||||
C58132 | Electrode impedance below 5 kiloOhms indicator | ElctrdImpdncBlw5kOhmInd | Indicator of whether the impedance of the electrodes used was below 5kiloOhms | Indicator of whether the impedance of the electrodes used was below 5kiloOhms | All electrode impedances below 5 kOhms? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-02 16:15:52.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C01581 | Weight unit of measure | WgtUoM | Unit of measure for the weight numerical value | Unit of measure for the weight numerical value | Weight: | Pounds;Kilograms | Pounds;Kilograms | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-25 08:54:08.2 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
2630200 | |||||||||
C58144 | Study blinding category | StudyBlindingCat | Category of blinding condition used in the study | Category of blinding condition used in the study | Experimental condition: | No blinding;Single blind;Double blind | No blinding;Single blind;Double blind | Alphanumeric | Adult | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:21:10.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C18965 | EEG behavioral state recorded other text | EEGBehavioralStateRecordedOTH | The free-text field related to 'EEG behavioral state recorded type' specifying other text. The recorded state(s) of the subject during the electroencephalogram (EEG) | The free-text field related to 'EEG behavioral state recorded type' specifying other text. The recorded state(s) of the subject during the electroencephalogram (EEG) | Other (please specify): | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||||
C58134 | Patient assessment activity state category | PtntAssmntActvtyStatCat | Category of the subject/participant's activity state during the assessment | Category of the subject/participant's activity state during the assessment | Is this measurement: | Active task;Resting state | Active task;Resting state | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 08:40:29.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C01582 | Height unit of measure | HgtUOM | Unit of measure for the height numerical value for participant | Unit of measure for the height numerical value for participant | Height: | Inches;Centimeters | Inches;Centimeters | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:58:54.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
2538920 | |||||||||
C58145 | Imaging session problem record method text | ImgSesnProbRecMthdTxt | Text describing the method used for recording problems that occur during an imaging session | Text describing the method used for recording problems that occur during an imaging session | Briefly describe procedure to be used for recording issues which may arise during session: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:30:38.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C19055 | EEG duration other text | EEGDurationOTH | The free-text field related to 'EEG duration' specifying other text. The length of time for the Electroencephalography (EEG) | The free-text field related to 'EEG duration' specifying other text. The length of time for the Electroencephalography (EEG) | Other | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||||
C58135 | Task active parameter text | TaskActivParameterTxt | Text describing the parameters of the active task | Text describing the parameters of the active task | If active, record task parameters: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 08:44:10.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||||
C08266 | Imaging post reconstruction filter type | ImgPstReconstrctFltrTyp | Type of post reconstruction filter used to smooth image data | Type of post reconstruction filter used to smooth image data | Offline filter parameters: | Lowpass;Other, specify;Band pass;High pass;None used | Lowpass;Other, specify;Band pass;High pass;None used | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-22 09:34:41.527 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C58146 | Eye movement electrooculography electrode use indicator | EyeMvmtEoGUseInd | Indicator of whether eye movement or electrooculography (EoG) electrodes were used | Indicator of whether eye movement or electrooculography (EoG) electrodes were used | Use of eye movement (EoG) electrodes? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:34:18.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C21117 | Subject name | SubjectName | Name of subject/participant | Name of subject/participan | Name: | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2015-06-12 15:16:39.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C58136 | Imaging artifact removal method type | ImgArtfctRmvlMthdTyp | Type of removal method used on imaging artifacts | Type of removal method used on imaging artifacts | Artifact removal: | AC - uses ICA or PCA for reconstruction;AO - artifact cut from record | AC - uses ICA or PCA for reconstruction (not recommended);AO - artifact cut from record (recommended) | Alphanumeric |
AC invalidates (distorts) data therefore not recommended |
http://www.youtube.com/watch?v=BfqCh2UeJik | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 08:45:36.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14549 | EEG location type | EEGLocTyp | The location of where the electroencephalogram (EEG) took place | The location of where the electroencephalogram (EEG) took place | Location: | Ambulatory;Other, specify;Outpatient qEEG lab;Bedside | Ambulatory;Other, specify;Outpatient qEEG lab;Bedside | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C58147 | Imaging EKG artifact electrode use indicator | ImgEKGArtfctElctrodeUseInd | Indicator of whether EKG artifact electrodes were used during the imaging session | Indicator of whether EKG artifact electrodes were used during the imaging session | Use of EKG artifact electrodes? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:36:39.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C54779 | EEG video other text | EEGVideoOTH | The free-text field related to 'EEG video indicator' specifying other text | The free-text field related to 'EEG video indicator' specifying other text | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-04-12 10:43:53.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C58137 | Quantitative EEG artifact free estimate reliable greater 90 percent indicator | qEEGArtFreEstRliablGrt90PctInd | Indicator of whether the reliability estimate of the edited, artifact-free quantitative EEG (qEEG) is greater than 90 percent | Indicator of whether the reliability estimate of the edited, artifact-free quantitative EEG (qEEG) is greater than 90 percent | Reliability estimates on edited, artifact-free qEEG > .90? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 08:49:57.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C14550 | EEG video indicator | EEGVideoInd | A test involving simultaneous electroencephalogram (EEG) and video recording | A test involving simultaneous electroencephalogram (EEG) and video recordin | Video? | No;Yes;Other specify | No;Yes;Other specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C58148 | Imaging surface electromyography electrode use indicator | ImgsEMGElctrodeUseInd | Indicator of whether surface electromyography (sEMG) electrodes were used during the imaging session | Indicator of whether surface electromyography (sEMG) electrodes were used during the imaging session | Use of sEMG electrodes? | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2018-02-05 09:36:39.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C54780 | EEG samping rate category | EEGSamplingRateCategory | Category of sampling rate for the EEG | Category of sampling rate for the EEG | Sampling rate: | 256 Hz;512 Hz;Other, specify;1024 Hertz;128 Hertz | 256 Hertz;512 Hertz;Other, specify;1024 Hertz;128 Hertz | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-04-12 10:53:05.0 | Quantitative Electroencephalography (qEEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |