CDE Detailed Report
Disease: Traumatic Brain Injury
Subdomain Name: Biomechanical Devices
CRF: Head Kinematics Estimates Form
Displaying 101 - 105 of 105
Subdomain Name: Biomechanical Devices
CRF: Head Kinematics Estimates Form
Displaying 101 - 105 of 105
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C06005 | Data collected date and time | DataCollDateTime | Date (and time, if applicable and known) the data were collected. This may be the date/time a particular examination or procedure was performed | Date (and time, if applicable and known) the data were collected. This may be the date/time a particular examination or procedure was performe |
Date of last event Time of last event |
Date or Date & Time | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 21:00:23.88 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
|||||||||||
C58457 | Head impact peak linear acceleration scalar value | HeadImpPeakLinearAccelerScaVal | The peak linear acceleration in scalar value in head impact assessment | The peak linear acceleration in scalar value in head impact assessmen | Scalar of linear acceleration | Numeric Values |
Residual sum of squares (RSS) value |
Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-08-03 15:45:50.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
||||||||||
C56917 | Head impact rotational velocity magnitude peak change value | HeadImpRotatVelMagPeakChVal | The value of the peak change in rotational velocity magnitude in head impact assessment | The value of the peak change in rotational velocity magnitude in head impact assessmen | Peak change in rotational velocity magnitude: | Numeric Values | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-08-03 15:45:50.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
|||||||||||
C57012 | Derivation method type | DrvtnMthdTyp | Type of derivation method | Type of derivation method | Derivation Method: | Alphanumeric | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-12-06 15:19:02.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events | 255 |
Free-Form Entry |
||||||||||
C56861 | Helmet manufacturer name | HelmetManufacturerName | The name of the manufacturer of the helmet worn by the subject/participant | The name of the manufacturer of the helmet worn by the subject/participan | Helmet Manufacturer (if any): | Alphanumeric |
Helmet manufacturer (company) owning the design and marketing the helmet. Fill in the appropriate helmet manufacturer per the instructions |
Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-08-03 14:00:00.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events | 255 |
Free-Form Entry |
- « first
- ‹ previous
- 1
- 2
- 3