CDE Detailed Report

Disease: system
Subdomain Name: Imaging Diagnostics
CRF: files

Displaying 1 - 50 of 62
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C18700 Imaging matrix size value other text ImgMatrixSizeValOTH The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters Matrix size (mm) Alphanumeric

Record in mm

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 16:00:38.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 50

Free-Form Entry

C15633 Imaging volumetric result ImgVolmtricReslt Results of volumetric measures/comparison of the image study Results of volumetric measures/comparison of the image study Volumetric measures/comparison results Alphanumeric

Volumetric measures/comparison results

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C02494 Imaging study date and time ImgStdyDateTime Date (and time, if applicable and known) the radiologic study was obtained Date (and time, if applicable and known) the radiologic study was obtained Date of scan Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:51:00.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10577 Imaging signal averages number ImgSignalAvgNum Number of signal acquisitions averaged in imaging acquisition Number of signal acquisitions averaged in imaging acquisition Number of averages Numeric Values

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18706 Imaging post reconstruction filter other text ImgPstReconstrctFltrOTH The free-text field related to 'Imaging post reconstruction filter type' specifying other text. Type of post reconstruction filter used to smooth image data The free-text field related to 'Imaging post reconstruction filter type' specifying other text. Type of post reconstruction filter used to smooth image data Reconstruction method used Alphanumeric

No additional instructions

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15579 Imaging diffusion type ImgDiffusionTyp Type of image output for the diffusion imaging study Type of image output for the diffusion imaging study Diffusion imaging type DTI;DSI;Other, specify DTI;DSI;Other, specify Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C56590 Imaging gross anatomical abnormality examination text IMmagGrossAnatAbnExamTxt Text describing any gross anatomical abnormalities found in the examination of images Text describing any gross anatomical abnormalities found in the examination of image Examination of images for gross anatomical abnormalities Alphanumeric

Report the technique used for detecting gross anatomical abnormalities (e.g. images inspected by neurologist)

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 10:45:00.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15636 Imaging comparison P-values number ImgComparPValNum P-values used for comparisons between cohorts or the group averages P-values used for comparisons between cohorts or the group averages Indicate the p-values used for comparisons between cohorts or the group averages Numeric Values

Indicate the p-values used for comparisons between cohorts or the group averages

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Magnet Strength 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10837 Imaging gap between slices measurement ImgGapBetwnSlicesMeasr Measurement of the gap between slices used in imaging acquisition Measurement of the gap between slices used in imaging acquisition Gap between slices (mm or %) Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C18714 Imaging radio frequency coil channel count other text ImgRFCoilChannelCtOTH The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Other, specify Alphanumeric

Record the number of coils for the applicable receiver coils.

No references available Adult;Pediatric Supplemental 2.00 2022-06-29 16:40:00.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15587 Imaging noise quality method text ImgNoisQualMethdTxt Description of image quality noise monitoring method used Description of image quality noise monitoring method used Noise Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C56591 Imaging morphometry analysis approach other text ImagMorphAnaAppOthrTxt Text specifying another approach to morphometry analysis Text specifying another approach to morphometry analysi Other, specify Alphanumeric No references available Adult;Pediatric Supplemental 1.00 2017-06-16 10:46:53.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15638 Imaging multiple comparisons method text ImgMultComparMethdTxt Type of method(s) chosen for correcting for multiple comparisons Text description of method(s) chosen for correcting for multiple comparisons Describe the method chosen for correcting multiple comparisons Alphanumeric

Describe the method chosen correcting multiple comparisons

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Name of scanner manufacturer GE;Siemens;Philips;Toshiba;Other, specify GE;Siemens;Philips;Toshiba;Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10838 Imaging voxel size axis 1 measurement ImgVoxelSizeAxis1Measr Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest Voxel size mm Numeric Values

Record in mm

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric No references available Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15591 Imaging patient movement quality method text ImgPatntMvmntQualMethdTxt Description of image quality participant/subject movement monitoring method used Description of image quality participant/subject movement monitoring method used Patient movement Alphanumeric

Report the technique used for measuring head movement in the scanner

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C56592 Imaging surface area result ImagSurfAreaReslt Results of surface area measures/comparison of the image study Results of surface area measures/comparison of the image stud Surface area measures/comparison results Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 10:51:56.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15639 Imaging coordinate of significant cluster text ImgCoordSigClustrTxt Text representing the coordinate of significant clusters Text representing the coordinate of significant clusters If applicable, indicate the coordinate of significant clusters Alphanumeric

If applicable, specify the coordinate of significant clusters. If not applicable, select 'N/A'

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Repetition time (TR) ms Numeric Values

Record in ms

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10842 Imaging analysis software name ImgAnlysisSftwrName Name of the software used for data processing or analysis of the imaging study Name of the software used for data processing or analysis of the imaging stud What processing tool(s)/package(s) type and version was used for analyzing the data? FSL;SPM;FreeSurfer;3D SLICER;TrackVis;Dipy;LC model;Other, specify FSL;SPM;FreeSurfer;3D SLICER;TrackVis;Dipy;LC model;Other, specify Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15594 Imaging distortions quality method name ImgDistortQualMethdTxt Description of image quality image distortion monitoring method used Description of image quality image distortion monitoring method used Distortions Alphanumeric

Report the technique used to detect distortions within MR images

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C56593 Imaging shape result ImagShapeReslt Results of shape measurements/comparison of the image study Results of shape measurements/comparison of the image stud Shape measures/comparison results Alphanumeric

No additional results

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 10:54:10.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15640 Imaging corrective analysis P-values number ImgCorrecAnlsysPValNum P-values used for any corrective analysis P-values used for any corrective analysis If applicable, indicate the p-values used for any correlative analysis Numeric Values

If applicable, specify the p-values used for any correlative analysis. If not applicable, select 'N/A'

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Echo time (TE) ms Numeric Values

Record in ms

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10843 Imaging analysis software version number ImgAnlysisSftwrVrsnNum The version number of the software used for quantitative analysis of the imaging study The version number of the software used for quantitative analysis of the imaging study Version Alphanumeric

Answer for each processing tool/package used to analyze the data.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C19024 Imaging diffusion analysis other text ImgDiffusionAnlsysOTH The free-text field related to 'Imaging diffusion analysis type' specifying other text. Type of diffusion analysis used The free-text field related to 'Imaging diffusion analysis type' specifying other text. Type of diffusion analysis used Other, specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15602 Imaging artifact removal correction indicator ImgArtifctRemovCorrectInd Indicator as to whether any correction for artifact removal was performed Indicator as to whether any correction for artifact removal was performed Was there any correction for artifact removal? Yes;No Yes;No Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C56594 Imaging significant cluster size text ImagSigClustSizeTxt Text describing the size of any significant clusters found Text describing the size of any significant clusters foun If applicable, indicate the size of the significant clusters Alphanumeric

If applicable, specify the coordinate of significant clusters. If not applicable, select 'N/A'

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 10:55:22.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C16210 Imaging data exported format text ImgDatExpFormatTxt Format of the data exported from scanner to local workstation/computer Format of the data exported from scanner to local workstation/computer What format was the data exported from the scanner to local workstations/computers ? Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08240 Imaging flip angle measurement ImgFlipAngleMeasr Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle Measurement of the angle, in degrees over which the radio frequency changes proton spin angle Flip angle (FA) Numeric Values No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

degree
C15362 Imaging QA/QC performed indicator ImgQAQCPerfInd Was image-based QA/QC performed? Was image-based QA/QC performed? Was QA performed on the data for artifact detection and potential exclusion of the subject data from analysis? Yes;No Yes;No Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C19074 Imaging analysis diffusion measurement other text ImgAnalysisDiffusionMeasrOTH The free-text field related to 'Imaging analysis diffusion measurement type' specifying other text. Type of analysis approach for diffusion tensor imaging (DTI) measurement The free-text field related to 'Imaging analysis diffusion measurement type' specifying other text. Type of analysis approach for diffusion tensor imaging (DTI) measurement Other, specify Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15605 Imaging registration technique used indicator ImgRegistTechUsedInd Indicator of whether a registration technique used to calculate the transformation to a standard average brain space Indicator of whether a registration technique used to calculate the transformation to a standard average brain space Was a registration technique used to calculate the transformation to a standard average brain space? Yes;No Yes;No Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C56596 Imaging white matter lesion anatomic site ImagWhiteMattLesAnatSite The location of the subject's white matter lesions The location of the subject's white matter lesion White matter lesions: location Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 12:30:21.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Field of view mm2 Numeric Values

Answer should be recorded as a dimension (AAxAA) in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C18009 Imaging threshold rationale text ImgThrshldRationaleTxt Text representing the rationale for choosing a certain threshold for the results Text representing the rationale for choosing a certain threshold for the results Describe the rationale for choosing the thresholds for the results Alphanumeric

Describe the rationale for choosing the thresholds for thresholding results

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15431 Imaging white matter volume measurement ImgWMVolMeasr Volume of white matter in the brain Volume of white matter in the brain White matter lesions: size Numeric Values

No additional information

No references available Adult;Pediatric Supplemental 3.00 2013-06-11 00:00:00.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

20 2000 milliliter
C55773 Imaging MRI scanner used count ImagMRIScanUsedCt The number of different MRI scanners that were used on the subject The number of different MRI scanners that were used on the subjec Number of different MRI scanners used Numeric Values

Report the number of different MRI scanners that were used for imaging participants during study.

No references available Adult;Pediatric Supplemental 1.00 2017-05-31 12:11:13.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C15608 Imaging registration technique type ImgRegistTechTyp Type of registration technique used Type of registration technique used Registration technique used Linear;Non-Linear Linear;Non-Linear Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C56597 Imaging white matter lesion count ImagWhiteMattLesCt The number of white matter lesions present in the image The number of white matter lesions present in the imag White matter lesions: number Numeric Values

No additional information

No references available Adult;Pediatric Supplemental 1.00 2017-06-16 12:31:15.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes Duration of the imaging scan in minutes Scan time duration minutes Numeric Values

Record in minutes

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C18011 Imaging motion correction technique pass criteria text ImgMotCorrTechPasCritTxt Text of correction technique and pass criteria text Type of correction technique and pass criteria text Describe pass criteria for motion Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15474 Imaging diffusion result value ImgDiffusionReslt The numeric value for diffusion tensor imaging (DTI) result The numeric value for diffusion tensor imaging (DTI) result DTI measures/comparison results Numeric Values

DTI measures/comparison results

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C55782 Imaging scanner software hardware update text ImagScanSoftHardUpdateTxt Text describing any scanner software or hardware updates during the time the study was performed Text describing any scanner software or hardware updates during the time the study was performe Scanner software or hardware updates during study performance Alphanumeric No references available Adult;Pediatric Supplemental 1.00 2017-05-31 12:43:09.0 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C15611 Imaging standard average brain text ImgStandrdAvgBrnTxt Text representing the standard average brain used Text representing the standard average brain used Report standard average brain used Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) Slice thickness (mm) Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C18615 Imaging analysis diffusion measurement type ImgAnalysisDiffusionMeasrTyp Type of analysis approach for diffusion tensor imaging (DTI) measurement Type of analysis approach for diffusion tensor imaging (DTI) measurement Analysis approach, DTI measures Fractional Anisotrophy (FA);Mean Diffusivity;Other, specify;Mean radical diffusivity;Mean axial diffusivity Fractional Anisotrophy (FA);Mean Diffusivity;Other, specify;Mean radical diffusivity;Mean axial diffusivity Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Anatomical Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

CSV