CDE Detailed Report

Disease: system
Subdomain Name: [php]
CRF: files

Displaying 1 - 50 of 62
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C52579 Brain oxygen partial pressure mean daily value BrnOxygnPartlPrssrMeanDailyVal Value of daily mean partial pressure of oxygen in brain tissue Value of daily mean partial pressure of oxygen in brain tissue Values obtained from five minute average: Mean daily value of brain tissue oxygen Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-25 11:40:36.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52593 Arterial pressure low measurement ArterialPressrLoMeasr Lowest measurement of the participant/subject's arterial pressure Lowest measurement of the participant/subject's arterial pressure Mean arterial pressure (MAP): Lowest value Numeric Values

millimeters of mercury

Adult;Pediatric Supplemental 1.00 2017-01-26 13:06:16.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 200 millimeters of mercury
C12422 Pulmonary gas exchange end tidal transcutaneous average carbon dioxide value PulmGasExchEndTidTranCO2AvgVal The average value of the pressure of the end tidal CO2 (ETCO2) or transcutaneous carbon dioxide (TCCO2) check The average value of the pressure of the end tidal CO2 (ETCO2) or transcutaneous carbon dioxide (TCCO2) check Mean daily end-tidal carbon dioxide (EtCO2) value (mmHg) Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52567 Elapsed time unit of measure ElapsedTimeUOM Unit of measure for the elapsed-time value captured by another data element Unit of measure for the elapsed-time value captured by another data element Days;Hours;minutes;seconds Days;Hours;minutes;seconds Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-24 11:20:38.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52613 Richmond Agitation Sedation Scale score RASSScore Score for the patient's agitation or sedation using the Richmond Agitation-Sedation Scale (RASS) Score for the patient's agitation or sedation using the Richmond Agitation-Sedation Scale (RASS Richmond Agitation Sedation Scale result 1;2;3;4;0;-1;-2;-3;-4;-5 1;2;3;4;0;-1;-2;-3;-4;-5 Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-26 16:00:40.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52580 Brain oxygen partial pressure measurement anatomical site BrnOxygnPrtlPrssrMeasrAnatSite Anatomic site of measurement of partial pressure of oxygen in brain tissue Anatomic site of measurement of partial pressure of oxygen in brain tissue Values obtained from five minute average: Site of partial pressure of brain tissue oxygen Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-25 11:49:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1] 255

Free-Form Entry

C52594 Mean arterial pressure measurement method type MAPMeasrMethodTyp Type of method used to determine mean arterial pressure (MAP) Type of method used to determine mean arterial pressure (MAP) Method used to obtain MAP: Invasive;Non-invasive Invasive;Non-invasive Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 13:08:44.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C12424 Pulmonary gas exchange highest end tidal transcutaneous carbon dioxide value PulmGasExchHiEndTidTranCO2Val The highest pressure of the end tidal CO2 (ETCO2) or transcutaneous CO2 (TCCO2) check while the participant/subject is sleeping The highest pressure of the end tidal CO2 (ETCO2) or transcutaneous CO2 (TCCO2) check while the participant/subject is sleeping Highest end-tidal carbon dioxide (EtCO2) value (mmHg) Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52568 Intracranial pressure measurement interval ICPMeasurementIntrvl Interval between intracranial pressure (ICP) measurements Interval between intracranial pressure (ICP) measurements ICP measurement interval Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-24 11:27:09.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52614 Neurological Pupil index value range grade NPIValueRangeGrade Grade within the range of measurement values for the Neurological Pupil index (NPi) value being reported Grade within the range of measurement values for the Neurological Pupil index (NPi) value being reporte Neuropupillary index Mean daily;Largest;Smallest Mean daily;Largest;Smallest Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 16:22:49.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52584 Cerebrospinal fluid excess volume 24 hour rate CSFExcessVol24HourRt Rate in volume per 24 hours of excess cerebrospinal fluid (CSF) removed from the patient Rate in volume per 24 hours of excess cerebrospinal fluid (CSF) removed from the patien Cerebrospinal fluid (CSF) volume: volume/day Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-26 11:02:30.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 2000 cubic centimeters per day
C01558 Partial pressure oxygen brain tissue measurement PPO2BrainTissMeasr Measurement of how much oxygen is dissolved in the brain tissue (PbtO2) Measurement of how much oxygen is dissolved in the brain tissue (PbtO2) Partial pressure of oxygen in brain tissue Numeric Values Adult;Pediatric Supplemental 5.00 2017-01-25 11:38:25.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 300
C52595 Mean arterial pressure invasive method anatomic site MAPInvasivMethodAnatSite Anatomic site where invasive method of measuring mean arterial pressure (MAP) was performed Anatomic site where invasive method of measuring mean arterial pressure (MAP) was performe Method used to obtain MAP: If invasive, specify site Radial;Axillary Radial;Axillary Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 13:11:41.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C14539 Cardiac output measurement CardOutputMeasr The measurement of volume of blood pumped by the heart per minute. The recommended unit for recording cardiac output is liters per minute (LPM) The measurement of volume of blood pumped by the heart per minute. The recommended unit for recording cardiac output is liters per minute (LPM Cardiac output Numeric Values Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

liter per minute
C52571 Intracranial pressure hour average value ICPHourAverageVal Mean value of intracranial pressure (ICP) measurements taken during the previous 60 minutes Mean value of intracranial pressure (ICP) measurements taken during the previous 60 minutes ICP measurement interval: hourly average Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-24 15:46:17.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

-10 300
C52615 Neurological Pupil index anatomic site NPIAnatSite Anatomic site of the Neurological Pupil index (NPi) value being reported Anatomic site of the Neurological Pupil index (NPi) value being reporte Neuropupillary index Right eye;Left eye Right eye;Left eye Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 16:22:49.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52585 Cerebrospinal fluid excess volume hour rate CSFExcessVolumeHourRt Rate in volume per 1 hour of excess cerebrospinal fluid (CSF) removed from the patient Rate in volume per 1 hour of excess cerebrospinal fluid (CSF) removed from the patien Cerebrospinal fluid (CSF) volume: volume/hr Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-26 11:02:30.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 500 cubic centimeters per hour
C01571 Intracranial pressure catheter anatomic site ICPCathetrAnatSite Anatomic site where the intracranial pressure (ICP) catheter is implanted in the participant/subject Anatomic site where the intracranial pressure (ICP) catheter is implanted in the participant/subject Anatomical ICP Reference point Intraparenchymal;Epidural;Intraventricular;Subdural;Other, specify Intraparenchymal;Epidural;Intraventricular;Subdural;Other, specify Alphanumeric Adult;Pediatric Supplemental 3.10 2022-07-11 12:13:39.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52596 Mean arterial pressure non-invasive method anatomic site MAPNonInvasivMethodAnatSite Anatomic site where non-invasive method of measuring mean arterial pressure (MAP) was performed Anatomic site where non-invasive method of measuring mean arterial pressure (MAP) was performe Method used to obtain MAP: If non-invasive, specify site Left Arm;Right Arm Left Arm;Right Arm Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 13:11:41.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C14541 Systemic vascular resistance measurement SystVasResMeasr A measurement of the arteriolar constriction throughout the body A measurement of the arteriolar constriction throughout the bod Systemic vascular resistance Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-26 00:00:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 999
C52572 Intracranial pressure 5 minute average value ICP5MinAverageVal Mean value of intracranial pressure (ICP) measurements taken during the previous 5 minutes Mean value of intracranial pressure (ICP) measurements taken during the previous 5 minutes ICP measurement interval: 5-minute average Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-24 15:46:17.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

-10 300
C52616 Neurological Pupil index score NPIScore Score on the Neurological Pupil index (NPi) Score on the Neurological Pupil index (NPi) Neuropupillary index Numeric Values

The index to evaluate reactivity of pupils objectively; values range from 0 to 5

Adult;Pediatric Supplemental 1.00 2017-01-26 16:22:49.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 5
C52586 Cardiac index value CardiacIndexValue Value of the cardiac index, which is the cardiac output from the left ventricle divided by the subject/participant's body surface area Value of the cardiac index, which is the cardiac output from the left ventricle divided by the subject/participant's body surface area Cardiac index (L/min/m^2) Numeric Values

This is a haemodynamic parameter that relates the cardiac output (CO) from the left ventricle in one minute to body surface area (BSA), thus relating heart performance to the size of the individual. The unit of measurement is liters per minute per square meter (L/min/m2).

Adult;Pediatric Supplemental 1.00 2017-01-26 11:15:11.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 20 liters per minute per square meter
C01572 Intracranial pressure device type ICPDeviceType Type of intracranial pressure (ICP) device implanted in the participant/subject Type of intracranial pressure (ICP) device implanted in the participant/subject Type of monitor used: Other, specify;Epidural probe;Subarachnoid probe;Intra-parenchymal probe;Intra-ventricular catheter Other, specify;Epidural probe;Subarachnoid probe;Intra-parenchymal probe (camino);Intra-ventricular catheter (EVD) Alphanumeric Adult;Pediatric Supplemental 3.00 2013-07-20 10:21:25.65 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52606 Ventilator mode status VentilatorModeStatus Status reflecting the ventilator's operational mode Status reflecting the ventilator's operational mode Ventilator mode Spontaneous;Assist;Controlled Spontaneous;Assist;Controlled Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 15:28:34.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C14542 Systemic vascular resistance unit of measure SystVasResUoM Units used to measure the systemic vascular resistance Units used to measure the systemic vascular resistanc Systemic vascular resistance dyn?s/cm-5;MPa?s/m-3;mmHg?min/L dyn?s/cm-5;MPa?s/m-3 (pascal seconds per cubic metre);mmHg?min/L (equivalent to hybrid reference units (HRU) or Woods units) Alphanumeric Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52573 Intracranial pressure average value other interval text ICPAvgValOtherIntrvlTxt The free-text field capturing an interval other than every 1 hour or every 5 minutes for which a mean intracranial pressure (ICP) value is being captured The free-text field capturing an interval other than every 1 hour or every 5 minutes for which a mean intracranial pressure (ICP) value is being capture ICP measurement interval: Other, specify Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-24 15:53:33.0 Vital Signs and Acute Physiological Measurements [php] [php_1] 255

Free-Form Entry

C54650 Intracranial pressure treatment threshold value ICPTreatThresholdVal The element related to the threshold used to require treatment of intracranial pressure (ICP) The element related to the threshold used to require treatment of intracranial pressure (ICP) Threshold used for ICP treatment: Numeric Values

mmHg

Adult;Pediatric Supplemental 4.00 2017-01-25 11:30:22.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52587 Stroke volume measurement StrokeVolumeMeasr Measurement of the volume of blood pumped from the left ventricle per heartbeat Measurement of the volume of blood pumped from the left ventricle per heartbea Stroke volume (mL) Numeric Values

The amount of blood ejected by the left ventricle in one contraction, described in milliliters (mL).

Adult;Pediatric Supplemental 1.00 2017-01-26 11:19:18.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 300 milliliters
C01573 Intracranial pressure measurement ICPMeasr Measurement of intracranial pressure (ICP), the amount of pressure that the cranium exerts on brain tissue, the brain's blood volume, and cerebrospinal fluid Measurement of intracranial pressure (ICP), the amount of pressure that the cranium exerts on brain tissue, the brain's blood volume, and cerebrospinal fluid Intracranial pressure (ICP) measurement (mmHg or cm H20) Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-25 11:30:22.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52607 Ventilator respiration rate VentilatorRespirationRt Rate of respiration provided by mechanical ventilator Rate of respiration provided by mechanical ventilato Ventilator mode: If controlled, specify: Rate Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-26 15:34:17.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

breaths per minute
C18726 Intracranial pressure device other text ICPDeviceOTH The free-text field related to 'Intracranial pressure device type' specifying other text. Type of intracranial pressure (ICP) device implanted in the participant/subject The free-text field related to 'Intracranial pressure device type' specifying other text. Type of intracranial pressure (ICP) device implanted in the participant/subject Type of device used: Other, specify Alphanumeric Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Vital Signs and Acute Physiological Measurements [php] [php_1] 4000

Free-Form Entry

C52574 Intracranial pressure other interval average value ICPOtherIntrvlAvgVal The average value of intracranial pressure captured at the interval other than 1 hour or 5 minutes specified in "Intracranial pressure average value other interval text" The average value of intracranial pressure captured at the interval other than 1 hour or 5 minutes specified in "Intracranial pressure average value other interval text ICP measurement interval: Other, specify Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-24 15:53:33.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

-10 300
C54651 Intracranial pressure over threshold duration ICPOverThresholdDur The element related to the length of time intracranial pressure (ICP) was above threshold The element related to the length of time intracranial pressure (ICP) was above threshold Time ICP over threshold: Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-25 11:30:22.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52588 Stroke volume measurement method type StrokeVolMeasrMethodTyp Type of method used to measure cardiac stroke volume Type of method used to measure cardiac stroke volume Stroke volume measured by Flowtrack;LidCo sensor;Pulmonary artery catheter;Transpulmonary thermodilution;Other, specify Flowtrack;LidCo (TM) sensor;Pulmonary artery (PA) catheter;Transpulmonary thermodilution;Other, specify Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-26 11:24:01.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C01574 Intracranial pressure maximum daily measurement ICPMaxDailyMeasr Highest measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Highest measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Highest ICP measurement Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-25 11:29:38.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52608 Ventilator breath volume value VentilatorBreathVolumeVal Value of the volume of gas per breath provided by a ventilator Value of the volume of gas per breath provided by a ventilator Ventilator mode: If controlled, specify: Volume Numeric Values Adult;Pediatric Supplemental 1.00 2017-01-26 15:40:57.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

liters per breath
C19340 Mean arterial pressure measurement value MeanArtPressrMeasrVal Result of a mean average pressure determination, expressed as a numeric value in millimeters of mercury (mmHg) to the nearest even number. The average pressure on the arteries from the beginning of one heartbeat to the beginning of the next heartbeat. Formally, it is the product of the cardiac output and the systemic vascular resistance, plus the central venous pressure Result of a mean average pressure determination, expressed as a numeric value in millimeters of mercury (mmHg) to the nearest even number. The average pressure on the arteries from the beginning of one heartbeat to the beginning of the next heartbeat. Formally, it is the product of the cardiac output and the systemic vascular resistance, plus the central venous pressur Mean arterial pressure (MAP) Numeric Values

milliliters of mercury

Adult;Pediatric Supplemental 1.00 2014-06-11 10:20:24.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

millimeters of mercury 2475893
C52575 Intracranial pressure minimum daily measurement ICPMinDailyMeasr Lowest measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Lowest measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Lowest ICP measurement Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-20 10:21:25.65 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C54652 Cerebral perfusion pressure lowest value CerebrlPerfusPressrLowVal Lowest value of the difference between the Mean Arterial Pressure (MAP) and the Intracranial Pressure (ICP). It represents the pressure gradient driving cerebral blood flow and hence oxygen and metabolite delivery Lowest value of the difference between the Mean Arterial Pressure (MAP) and the Intracranial Pressure (ICP). It represents the pressure gradient driving cerebral blood flow and hence oxygen and metabolite deliver Lowest CPP measurement: Numeric Values Adult;Pediatric Supplemental 3.00 2013-07-20 10:21:25.65 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52589 Stroke volume variation measurement method type StrokeVolVarMeasrMethodTyp Type of method used to measure variation in cardiac stroke volume Type of method used to measure variation in cardiac stroke volume Stroke volume variation measured by Arterial line Arterial line Alphanumeric Adult;Pediatric Supplemental 1.10 2018-07-30 00:00:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C01575 Intracranial pressure mean daily measurement ICPMeanDailyMeasr Mean measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Mean measurement of the participant's/ subject's intracranial pressure (ICP) over the 24-hour period Mean daily ICP measurement Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-25 11:29:14.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52609 Ventilation pressure support gas pressure value VntlatnPressrSupprtGasPrssrVal Value of the gas pressure supplied to the patient in pressure support ventilation Value of the gas pressure supplied to the patient in pressure support ventilatio Ventilator pressure support (mmHg) Numeric Values

Millimeters of mercury

Adult;Pediatric Supplemental 1.00 2017-01-26 15:44:36.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

millimeters of mercury
C19849 Medical history ventilator setting type MedHistVentltSettingTyp Type of Ventilator settings Type of Ventilator settings Ventilator settings Tidal Volume;PEEP;Backup rate Tidal Volume;PEEP;Backup rate Alphanumeric Adult;Pediatric Supplemental 2.00 2017-01-26 00:00:00.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C52576 Cerebral perfusion value source type CerbrlPerusnValSourceTyp Type of the source of the cerebral perfusion value Type of the source of the cerebral perfusion value Cerebral perfusion value source Invasive;Non-invasive Invasive;Non-invasive Alphanumeric Adult;Pediatric Supplemental 1.00 2017-01-25 11:32:15.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

C54653 Cerebral perfusion pressure under threshold duration CPPUnderThresholdDur The element related to the length of time cerebral perfusion pressure (CPP) was below threshold The element related to the length of time cerebral perfusion pressure (CPP) was below threshold Time CPP under threshold (50 mmHg) Numeric Values Adult;Pediatric Supplemental 4.00 2017-01-25 11:30:22.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52590 Pulse pressure variation measurement PulsePressrVariatnMeasr Measurement of the variation in pulse pressure Measurement of the variation in pulse pressure Pulse pressure variation (mmHg) Numeric Values

Variation in pulse pressure over time (mostly depending on respiratory cycle): systolic apressure - diastolic pressure

Adult;Pediatric Supplemental 1.00 2017-01-26 11:44:53.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

0 100 millimeters of mercury
C01578 Cerebral perfusion pressure value CerebrlPerfusPressrVal Value of the difference between the Mean Arterial Pressure (MAP) and the Intracranial Pressure (ICP). It represents the pressure gradient driving cerebral blood flow and hence oxygen and metabolite delivery Value of the difference between the Mean Arterial Pressure (MAP) and the Intracranial Pressure (ICP). It represents the pressure gradient driving cerebral blood flow and hence oxygen and metabolite deliver Cerebral perfusion pressure value Numeric Values

The value of the difference between the Mean Arterial Pressure (MAP) and the Intracranial Pressure (ICP). It represents the pressure gradient driving cerebral blood flow and hence oxygen and metabolite delivery

Adult;Pediatric Supplemental 3.00 2013-07-20 10:21:25.65 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

C52610 Ventilation positive end-expiratory pressure gas pressure value VntlatnPEEPGasPrssrVal Value of the gas pressure supplied to the patient in positive end-expiratory pressure (PEEP) ventilation Value of the gas pressure supplied to the patient in positive end-expiratory pressure (PEEP) ventilatio Positive end-expiratory pressure (PEEP) (mmHg) Numeric Values

Millimeters of mercury

Adult;Pediatric Supplemental 1.00 2017-01-26 15:44:36.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Free-Form Entry

millimeters of mercury
C22804 Pain present eleven point intensity scale PainPrsnt11IntensityScl Scale for the participant's current pain intensity based on an a scale of 0-10 Scale for the participant's current pain intensity based on an a scale of 0-10 Pain scale 0;1;10;2;3;4;5;6;7;8;9 0;1;10;2;3;4;5;6;7;8;9 Numeric Values Adult;Pediatric Supplemental 4.00 2023-05-18 16:39:30.0 Vital Signs and Acute Physiological Measurements [php] [php_1]

Single Pre-Defined Value Selected

CSV