CDE Detailed Report
Disease: content
Subdomain Name: Imaging Diagnostics
CRF: welcome
Displaying 51 - 57 of 57
Subdomain Name: Imaging Diagnostics
CRF: welcome
Displaying 51 - 57 of 57
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C10586 | Imaging bandwidth value | ImgBandwidthVal | Value, in Hertz per pixel, of bandwidth used in imaging acquisition | Value, in Hertz per pixel, of bandwidth used in imaging acquisitio | DTI sequence parameters, Band width | Numeric Values |
Answer should be recorded in Hx/Pixel |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C18703 | Imaging parallel acquisition used other text | ImgParallelAcquistionMethodOTH | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Exploratory | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10683 | Imaging T2 weighted spin-echo acquired indicator | ImgT2WSpinEchoAcquireInd | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correctio | T2-weighted spin-echo acquired | Yes;No | Yes;No | Alphanumeric |
For B0-susceptibility distortion correction. |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08242 | Imaging acquisition duration | ImgAcquisitionDur | Duration of the imaging scan in minutes | Duration of the imaging scan in minutes | DTI sequence parameters, Acquisition time | Numeric Values |
Answer should be recorded in minutes |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
minute | |||||||||
C17798 | Imaging contrast agent name | ImgContrastAgentName | Name of imaging contrast agent used | Name of imaging contrast agent used | Contrast Used: If Yes, name of the contrast: | Alphanumeric | No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
||||||||||
C10587 | Imaging echo spacing value | ImgEchoSpcVal | Measurement, in milliseconds, of the echo spacing used in diffusion acquisition | Measurement, in milliseconds, of the echo spacing used in diffusion acquisitio | DTI sequence parameters, Echo spacing | Numeric Values |
Answer should be recorded in milliseconds (ms). Must be answered with Echo Train Length and number of shots |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C18708 | Imaging pulse sequence type other text | ImgPulseSeqTypOTH | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Exploratory | 2.00 | 2022-07-01 14:55:04.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |