CDE Detailed Report
Subdomain Name: Electrodiagnostics
CRF: Motor Evoked Potentials
Displaying 1 - 16 of 16
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C58643 | Electrophysiology facilitation type | ElectrophysFacilitatnTyp | Type of facilitation or reinforcement employed in electrophysiology testing | Type of facilitation or reinforcement employed in electrophysiology testin | Facilitation type, e.g., force | Alphanumeric |
Specify type of Reinforcement if required to evoke a response |
Adult;Pediatric | Supplemental | 1.00 | 2019-11-04 14:31:34.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 255 |
Free-Form Entry |
||||||||||
C19310 | Latency average value | LatencyAverageVal | The average value of latency | The average value of latency | Latency average | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2014-06-06 12:46:32.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
||||||||||||
C19311 | Amplitude average value | AmplitudeAverageVal | Average value of amplitude | Average value of amplitude | Amplitude average | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2014-06-06 12:49:05.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
Milliampere | |||||||||||
C19338 | Electrophysiology test coil location text | ElctrophysTstCoilLocatnTxt | Text articulating the location of coil in electrophysiology test | Text articulating the location of coil in electrophysiology test | Coil location | Alphanumeric |
Specify location of stimulating electrode with respect to a scalp reference |
Adult;Pediatric | Supplemental | 1.00 | 2014-06-11 09:57:38.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 4000 |
Free-Form Entry |
||||||||||
C01708 | Lab test performed indicator | LabTestPerfInd | Indicator of whether the lab test has been performed on the participant/subject | Indicator of whether the lab test has been performed on the participant/subject | Facilitation Y/N | Yes;No | Yes;No | Alphanumeric | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Single Pre-Defined Value Selected |
3158111 | |||||||||
C19360 | Transcranial magnetic stimulation coil type | TMSCoilTyp | Type of stimulating coil used during transcranial magnetic stimulation | Type of stimulating coil used during transcranial magnetic stimulatio | Alphanumeric | Adult;Pediatric | Supplemental | 1.00 | 2014-06-12 16:02:07.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 255 |
Free-Form Entry |
||||||||||||
C01711 | Lab test result unit of measure | LabTestResltUoM | Unit of measure for the laboratory test result | Unit of measure for the laboratory test result | e.g. in % MVC | Alphanumeric |
Record the units the numeric results for each laboratory test are measured in. See the data dictionary for additional information on coding the unit of measure using Unified Coed for Units of Measure (UCUM) |
Unified Code for Units of Measure - http://unitsofmeasure.org/ | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 255 |
Free-Form Entry |
2787947 | ||||||||
C19361 | Lab test participant position type | LabTestParticipntPositnTyp | The arrangement or orientation of the participant's body at the time the lab test was performed | The arrangement or orientation of the participant's body at the time the lab test was performe | Specify position of patient (seated/recumbent) | Recumbent;Sitting | Recumbent;Sitting | Alphanumeric | Adult;Pediatric | Supplemental | 1.00 | 2014-06-12 16:16:44.0 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Single Pre-Defined Value Selected |
2008432 | |||||||||
C02411 | Laterality type | LatTyp | Laterality type relative to the anatomic site of the body examined or affected | Laterality type relative to the anatomic site of the body examined or affected | Left;Right;Midline | Left;Right;Midline | Alphanumeric | Adult;Pediatric | Supplemental | 3.00 | 2013-08-28 16:08:00.453 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Single Pre-Defined Value Selected |
|||||||||||
C21658 | Electrodiagnostic exam date | ElectrodiagExamDate | The date of the electrodiagnostic exam testing | The date of the electrodiagnostic exam testin | Date of Exam: | Date or Date & Time | Adult;Pediatric | Supplemental | 3.00 | 2013-07-16 14:01:43.01 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
||||||||||||
C10171 | Trial number | TrialNum | The number representing the sequence for any repeated measure test or assessment when it is performed multiple times | The number representing the sequence for any repeated measure test or assessment when it is performed multiple times | Trial 1;Trial 2;Trial 3 | Trial 1;Trial 2;Trial 3 | Alphanumeric |
Repeat each stimulation three times |
Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||||
C21659 | Central motor conduction time | CtrlMotorCondTime | Duration of central motor conduction as part of motor evoked potential testing | Duration of central motor conduction as part of motor evoked potential testin | Central Motor Conduction Time | Numeric Values | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
millisecond | |||||||||||
C10789 | Transcranial magnetic stimulation muscle studied name | TMSMuscleStudiedName | Name of the muscle studied using transcranial magnetic stimulation (TMS) | Name of the muscle studied using transcranial magnetic stimulation (TMS) | Muscle name | Alphanumeric |
Responses should be recorded from different muscles innervated from different roots to enable localization of any conduction deficits |
Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 255 |
Free-Form Entry |
||||||||||
C12697 | Electrophysiology motor nerve latency value | ElctphysMotrNervLatncyVal | The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study | The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study | Latency | Numeric Values | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
microsecond | |||||||||||
C12699 | Electrophysiology motor nerve amplitude measurement | ElctphysMotrNervAmpMeasr | The measured amplitude of signal response to test stimulation during the motor nerve conduction study | The measured amplitude of signal response to test stimulation during the motor nerve conduction study | Amplitude | Numeric Values | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points |
Free-Form Entry |
microVolt | |||||||||||
C17865 | Transcranial magnetic stimulation comments text | TMSCommentsTxt | Text field for comments on the transcranial magnetic stimulation (TMS) performed | Text field for comments on the transcranial magnetic stimulation (TMS) performed | Comments | Alphanumeric | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Motor Evoked Potentials | Electrodiagnostics | Outcomes and End Points | 255 |
Free-Form Entry |