CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C06253 Heart rate status HeartRateStatus Findings after taking a participant's pulse during the examination Findings after taking a participant's pulse during the examinatio Pulse Regular;Irregular Regular;Irregular Alphanumeric

Choose one. Both abnormal heart rate and rhythm are commonly observed in individuals with cervical and high thoracic spinal cord lesions.

Krassioukov A, Alexander MS, Karlsson AK, Donovan W, Mathias CJ, Biering-SØrensen F. International spinal cord injury cardiovascular function basic data set. Spinal Cord. 2010 Aug;48(8):586-90. Claydon,V.E., Elliott,S.L., Sheel,A.W. & Krassioukov,A. Card Adult Supplemental 3.00 2013-07-17 09:26:36.973 Vital Signs and Tests Vital Signs and Other Body Measures Assessments and Examinations

Single Pre-Defined Value Selected

C01554 Oxygen saturation measurement O2SatMeasr Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetry Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetr Oxygen saturation (%) Numeric Values

The suggested range is 0-100. Add date stamp for when assessed. Recommended for collection on admission and daily as required by protocol.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Vital Signs and Tests Vital Signs and Other Body Measures Assessments and Examinations

Free-Form Entry

0 100 percent
C18123 Xray study urinary tract global result type XrayStdyUrnTctGlblResltNormInd The result type related to the X-ray study of the urinary tract found functional and anatomical conditions The result type related to the X-ray study of the urinary tract found functional and anatomical condition X-ray of the urinary tract – Kidney Ureter Bladder (KUB) Normal;Kidney stone;Stone in ureter;Bladder stone;Other findings Normal;Kidney stone;Stone in ureter;Bladder stone;Other findings Alphanumeric

Normal: Normal anatomical conditions werefound at the investigation; in particular, no stones in the kidneys, ureters or bladder.
Kidney stone: This means urinary stone(s) was/were found in the renal pelvis or renal parenchyma at the right and/or the left side.
Stone in ureter: This means urinary stone(s) was/were found in the ureter at the right and/or the left side.
Bladder stone: This means urinary stone(s) was/were found in the urinary bladder. Stones of any kind or size qualify for documentation.
Other findings: Findings of any specific deviations from the normal state not documented above can be stated in a text-field, from where it will be possible to retrieve more detailed data whenever necessary. Because many possible findings exist, it is not practical to give an exact list of findings.

Biering-SØrensen F, Craggs M, Kennelly M, Schick E, Wyndaele J-J. International urinary tract imaging basic spinal cord injury data set. Spinal Cord 2009 May;47(5):379-83. Adult;Pediatric Supplemental 4.00 2013-07-17 09:26:37.0 Vital Signs and Tests Vital Signs and Other Body Measures Assessments and Examinations

Single Pre-Defined Value Selected

C06150 Urography method type UrgrphyMethdTyp Identifies which methods were performed on the urinary tract Identifies which methods were performed on the urinary tract Method used Intravenous pyelography/Urography;CT urography;Ultrasound of the urinary tract Intravenous pyelography/Urography;CT urography;Ultrasound of the urinary tract Alphanumeric

Choose one. If more than one method was performed on the same date then enter the results separately.

Biering-SØrensen F, Craggs M, Kennelly M, Schick E, Wyndaele J-J. International urinary tract imaging basic spinal cord injury data set. Spinal Cord 2009;47:379-83. Adult Supplemental 3.00 2013-07-17 09:26:36.973 Vital Signs and Tests Vital Signs and Other Body Measures Assessments and Examinations

Single Pre-Defined Value Selected

C18169 Laboratory procedure triglycerides measurement LabProcedTriglyceridesMeasr Measurement of the amount of triglycerides in the participant's blood Measurement of the amount of triglycerides in the participant's blood Triglycerides (TG) Numeric Values Bauman WA, Biering-SØrensen F, Krassioukov A. The international spinal cord injury endocrine and metabolic function basic data set. Spinal Cord. 2011 Oct;49(10):1068-72. doi: 10.1038/sc.2011.51. Adult Supplemental 4.00 2024-02-29 15:53:45.0 Vital Signs and Tests Vital Signs and Other Body Measures Assessments and Examinations

Free-Form Entry

milligrams per deciliter
CSV