CDE Detailed Report
Disease: Multiple Sclerosis
Subdomain Name: Imaging Diagnostics
CRF: Imaging OCT Analysis -Cirrus Macular Thickness
Displaying 1 - 7 of 7
Subdomain Name: Imaging Diagnostics
CRF: Imaging OCT Analysis -Cirrus Macular Thickness
Displaying 1 - 7 of 7
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C15323 | Optical coherence tomography (OCT) macular cube laterality type | OCTMacularCubeLtrltyTyp | The side of the eyes examined during macular cube analysis by optical coherence tomography (OCT) | The side of the eyes examined during macular cube analysis | Laterality Type | OD;OS | right eye;left eye | Alphanumeric |
No additional instructions |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C15331 | Optical coherence tomography (OCT) macular cube signal strength value | OCTMacularcubeSignalStrgthVal | Signal strength of optical coherence tomography (OCT) machine when scanning macula of eye (1-10) | Signal strength of optical coherence tomography (OCT) machine when scanning macula of eye (1-10) | Signal Strength | 1;2;3;4;5;6;7;8;9;10 | 1;2;3;4;5;6;7;8;9;10 | Numeric Values |
To be answered for OD and/or OS, as applicable |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C15339 | Optical coherence tomography (OCT) macular cube total volume measurement | OCTmclrcubtotvolmeas | Total volume of the macular cube by optical coherence tomography (OCT) | Total volume of the macular cube by optical coherence tomography (OCT | Total volume of the macular cube | Numeric Values |
Record in cubic millimeters (mm3). To be answered for OD and/or OS, as applicable. |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
cubic millimeter | |||||||||
C15343 | Optical coherence tomography (OCT) total macular volume abnormal status | OCTTtlMaculaVolAbnrmlsts | This variable indicates whether the macular volume is abnormally low based on optical coherence tomography (OCT) | This variable indicates whether the macular volume is abnormally low based on optical coherence tomography (OCT | Is the macular volume abnormally low | 0;1;2;9;99 | Macula is of normal volume (green on the report);macular volume is abnormally low. in the 5th percentile (yellow on the report);macular volume is abnormally low, in the 1st percentile (red on the report);Macular volume is abnormally great, in the 95th percentile (pale yellow on the report);Macular volume is abnormally great, in the 99th percentile (pale pink on the report) | Numeric Values |
Choose only one. To be answered for OD and/or OS, as applicable. |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C15352 | Imaging average macular cube thickness measurement | ImgAvgMclrThickMeas | Average macular thickness of the cube | Average macular thickness of the cube | Average macular thickness of the cube | Numeric Values |
Record in microns (?). To be answered for OD and/or OS, as applicable. |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
micron | |||||||||
C15359 | Imaging average macular thickness abnormal status | ImgAvMacThAbnrmlStatus | The indicator is the average macular thickness is abnormally low | The indicator is the average macular thickness is abnormally lo | Is the average macular thickness abnormally low? | 0;1;2;9;99 | Macula is of normal volume (green on the report);Macular volume is abnormally low, in the 5th percentile (yellow on the report);macular volume is abnormally low, in the 1st percentile (red on the report);Macular volume is abnormally great, in the 95th percentile (pale yellow on the report);Macular volume is abnormally great, in the 99th percentile (pale pink on the report) | Numeric values |
Choose only one. To be answered for OD and/or OS, as applicable. |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C15316 | Optical coherence tomography (OCT) macular cube scan pattern type | OCTMacularCubeScnPttrnTyp | The scan pattern used for the optical coherence tomography (OCT) | The scan pattern used for the optical coherence tomography (OCT) | Macular cube scan pattern | Macular cube 512 x 128;Macular cube 200 x 200 | Macular cube 512 x 128;Macular cube 200 x 200 | Alphanumeric |
Choose only one |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-06-11 00:00:00.0 | Imaging OCT Analysis -Cirrus Macular Thickness | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |