CDE Detailed Report

Disease: Multiple Sclerosis
Subdomain Name: Imaging Diagnostics
CRF: Imaging OCT Analysis - Contrast and Visual Acuity

Displaying 1 - 5 of 5
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C15348 Optical coherence tomography Pelli-Robson contrast sensitivity test log score value OCTPelRbnCntrstSenTstScoreVal The log score of the Pelli-Robson Contrast Sensitivity Test The log score of the Pelli-Robson Contrast Sensitivity Test Pelli-Robson Contrast Sensitivity Test, log score Numeric Values

To be answered for OD, OS, and binocular, as applicable. Acceptable range for this result is 0.00-2.25.

No references available Adult;Pediatric Exploratory 3.00 2013-06-11 00:00:00.0 Imaging OCT Analysis - Contrast and Visual Acuity Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 2.25
C15319 Optical coherence tomography contrast and visual acuity testing laterality type OCTContrastVATstngLtrltyTyp The eye examined during high/low contrast and visual acuity testing by optical coherence tomography (OCT) The eye examined during high/low contrast and visual acuity testing Laterality Type OD;OS;binocular right eye;left eye;both eyes Alphanumeric No references available Adult;Pediatric Exploratory 3.00 2013-06-11 00:00:00.0 Imaging OCT Analysis - Contrast and Visual Acuity Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C15326 Optical coherence tomography high contrast visual acuity count OCTContrastVslActyCt The number of letters read correctly at 3.2 meters as a measurement of high contrast tomography (OCT) visual acuity The number of letters read correctly at 3.2 meters as a measurement of high contrast visual acuity Number of letters read correctly at 3.2 meters (high contrast visual acuity) Numeric Values

To be answered for OD, OS, and binocular, as applicable. Acceptable range for this result is 0-70.

No references available Adult;Pediatric Exploratory 3.00 2013-06-11 00:00:00.0 Imaging OCT Analysis - Contrast and Visual Acuity Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 70
C15334 Optical coherence tomography low contrast Sloan letter chart 2.5 binocular count OCTlowContrastSloan2_5BinocCt The number of letters read correctly at low contrast on a Sloan letter chart at 2.5% from 2 meters The number of letters read correctly at low contrast on a Sloan letter chart at 2.5% from 2 meters Number of letters read correctly at 2 meters (low contrast Sloan letter chart 2.5%) Numeric Values

To be answered for OD, OS, and binocular, as applicable. Acceptable range for this result is 0-70.

No references available Adult;Pediatric Exploratory 3.00 2013-06-11 00:00:00.0 Imaging OCT Analysis - Contrast and Visual Acuity Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 70
C15342 Optical coherence tomography low contrast Sloan letter chart 1.25 binocular count OCTContrastSloanChrtBinocCt The number of letters read correctly at low contrast on a Sloan letter chart at 1.25% at 2 meters The number of letters read correctly at low contrast on a Sloan letter chart at 1.25% at 2 meters Number of letters read correctly at 2 meters (low contrast Sloan letter chart 1.25%) Numeric Values

To be answered for OD, OS, and binocular, as applicable. Acceptable range for this result is 0-70.

No references available Adult;Pediatric Exploratory 3.00 2013-06-11 00:00:00.0 Imaging OCT Analysis - Contrast and Visual Acuity Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 70
CSV