CDE Detailed Report

Disease: Huntington's Disease
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance (MR) Localization Imaging

Displaying 1 - 37 of 37
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Camera Software Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C19064 Imaging functional magnetic resonance imaging task other text ImgFMRITaskOTH The free-text field related to 'Imaging functional magnetic resonance imaging task type' specifying other text. Tasks performed during a functional magnetic resonance imaging (fMRI) scan The free-text field related to 'Imaging functional magnetic resonance imaging task type' specifying other text. Tasks performed during a functional magnetic resonance imaging (fMRI) scan Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-08-30 17:06:52.8 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition IN-PLANE RESOLUTION MATRIX Numeric Values

This value should be captured in millimeters by millimeters (mm X mm). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
C17748 Imaging neurologic other data collected indicator ImgNeuroOtherDataCollectedInd The indicator whether other types of neuroimaging data were collected during this scan visit The indicator whether other types of neuroimaging data were collected during this scan visit Were any other types of neuroimaging data collected during this scan visit? Yes;No Yes;No Alphanumeric No references available Adult Supplemental 3.00 2013-08-30 17:06:52.8 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition TR Numeric Values

This value should be captured in milliseconds (ms) Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10685 Imaging slice orientation type ImgSliceOrientTyp Type of slice orientation used in imaging acquisition Type of slice orientation used in imaging acquisition ORIENTATION Axial;Coronal;Sagittal Axial;Coronal;Sagittal Alphanumeric

Answer for each sequence performed. Choose only one

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:40.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17749 Imaging neurologic other data collected type ImgNeuroOtherDataCollectedTyp Other types of neuroimaging data that may have been collected during this scan visit Other types of neuroimaging data that may have been collected during this scan visit If yes, indicate the other types of neuroimaging data collected Magnetic Resonance Spectroscopy(MRS);Functional MRI(fMRI);Other, specify Magnetic Resonance Spectroscopy(MRS);Functional MRI(fMRI);Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-08-30 17:06:52.8 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition TE Numeric Values

This value should be captured in milliseconds (ms). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10837 Imaging gap between slices measurement ImgGapBetwnSlicesMeasr Measurement of the gap between slices used in imaging acquisition Measurement of the gap between slices used in imaging acquisition GAP Numeric Values

This value should be captured in millimeters (mm). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17750 Imaging functional magnetic resonance imaging task type ImgFMRITaskTyp Tasks performed during a functional magnetic resonance imaging (fMRI) scan Tasks performed during a functional magnetic resonance imaging (fMRI) scan Specify tasks Finger tapping;N-back;Other, specify Finger tapping;N-back;Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-08-30 17:06:52.8 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08240 Imaging flip angle measurement ImgFlipAngleMeasr Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle Measurement of the angle, in degrees over which the radio frequency changes proton spin angle FLIP ANGLE Numeric Values

This value should be captured in degrees. Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

degree
C10927 Imaging inversion time duration ImgInversionTimeDur Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence TI Numeric Values

This value should be captured in milliseconds (ms). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:46.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C18691 Imaging artifact other text ImgArtifactOTH The free-text field related to 'Imaging artifact type' specifying other text. The artifacts present on the scan The free-text field related to 'Imaging artifact type' specifying other text. The artifacts present on the scan Other, specify Alphanumeric

Only answered if Yes is answered for "Are there any obvious artifacts?"

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters FIELD OF VIEW Numeric Values

This value should be captured in millimeters by millimeters (mm X mm). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C14961 Imaging excitation number ImgExcitationNum Number of times each line of k-space data is acquired during the scan Number of times each line of k-space data is acquired during the scan NEX Numeric Values

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-14 19:48:50.273 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18700 Imaging matrix size value other text ImgMatrixSizeValOTH The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters The free-text field related to 'Imaging matrix size value', specifying other text. Value representing the imaging matrix size in millimeters Other, specify Alphanumeric

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 16:00:38.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 50

Free-Form Entry

C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes Duration of the imaging scan in minutes DURATION Numeric Values

This value should be captured in minutes. Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C14962 Imaging acquisition entire brain coverage indicator ImgAcqEntireBrnCoverageInd Indicator of whether the imaging acquisition covered the entire brain Indicator of whether the imaging acquisition covered the entire brain Covers entire brain? Yes;No Yes;No Alphanumeric

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-14 19:48:50.273 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18708 Imaging pulse sequence type other text ImgPulseSeqTypOTH The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used Other, specify Alphanumeric

Choose all that apply. For each pulse sequence checked, record the scan parameters in the table in question #6 - Scan parameters;In this row, for each column list each pulse sequence checked in question #3 (e.g., MPRAGE, FLAIR, DTI etc.)

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 14:55:04.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08243 Imaging matrix size value ImgMatrixSizeVal Value representing the imaging matrix size in millimeters Value representing the imaging matrix size in millimeters MATRIX SIZE 64 x 64;128 x 128;512 x 512;Other, specify;256 x 256 64 x 64;128 x 128;512 x 512;Other, specify;256 x 256 Alphanumeric

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

millimeter
C14963 Imaging field maps acquisition indicator ImgFildMapsAcqInd Indicator of whether field maps were acquired during the acquisition Indicator of whether field maps were acquired during the acquisition FIELD MAPS ACQUIRED? Yes;No;Not applicable Yes;No;Not applicable Alphanumeric

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-14 19:48:50.273 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Field strength 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

Include type of scanner and manufacturer

No references available Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) SLICE THICKNESS Numeric Values

This value should be captured in millimeters (mm). Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C14964 Sedation used indicator SedationUsedInd Indicator of whether the participant was administered any sedation Indicator of whether the participant was administered any sedation Was any sedation administered? Yes;No Yes;No Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:29.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Scanner Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify Alphanumeric

Include type of scanner and manufacturer

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18717 Imaging scanner model other text ImgScannerModelOTH The free-text field related to 'Imaging scanner model name' specifying other text. Name of model of imaging scanner The free-text field related to 'Imaging scanner model name' specifying other text. Name of model of imaging scanner Alphanumeric Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] ; Haacke, E.M., Duhaime, A.C., Gean, A.D., Riedy, G., Wintermark, M., Mukherjee, P., Brody, D.L., DeGraba, T., Duncan, T.D., and Elovic, E. (2010). Common data elements in radiologic imaging of traumatic brain injury. Journal of Magnetic Resonance Imaging 32, 516-543, DOI:10.1002/jmri.22259 Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08245 Imaging slice count ImgSliceCt Count representing the total number of single image planes captured during imaging acquisition Count representing the total number of single image planes captured during imaging acquisition # of Slices Numeric Values

Answer for each sequence performed.

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C14965 Imaging artifacts indicator ImgArtifactInd Indicator of any obvious artifacts in the image Indicator of any obvious artifacts in the image Are there any obvious artifacts? Yes;No Yes;No Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.00 2013-07-14 19:48:50.273 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02497 Imaging scanner model name ImgScannerModelName Name of model of imaging scanner Name of model of imaging scanner Symphony;Trio;Achieva;Signa;Other, specify;Skyra Symphony;Trio;Achieva;Signa;Other, specify;Skyra Alphanumeric Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] ; Haacke, E.M., Duhaime, A.C., Gean, A.D., Riedy, G., Wintermark, M., Mukherjee, P., Brody, D.L., DeGraba, T., Duncan, T.D., and Elovic, E. (2010). Common data elements in radiologic imaging of traumatic brain injury. Journal of Magnetic Resonance Imaging 32, 516-543, DOI:10.1002/jmri.22259 Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10568 Imaging radio frequency coil channel count ImgRFCoilChannelCt Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Record the number of coils for the applicable receiver coils. 1;8;16;32 channels;Other, specify Single coil;8 channels;16 channels;32 channels;Other, specify Alphanumeric

No references available

Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14966 Imaging artifact type ImgArtifactTyp The artifacts present on the scan The artifacts present on the scan If yes, specify the artifacts Excessive movement;Poor gray/white contrast;For DTI: Excessive table movement;Other, specify Excessive movement;Poor gray/white contrast;For DTI: Excessive table movement;Other, specify Alphanumeric

Only answered if Yes is answered for "Are there any obvious artifacts?"

No references available Adult;Pediatric Supplemental 3.00 2013-07-14 19:48:50.273 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used Pulse Sequence;Sequence Type MPRAGE;SPGR;GRE;FLASH;SWI;DTI;FLAIR;SPACE/VISTA;TSE/FSE;Other, specify MPRAGE;SPGR;GRE;FLASH;SWI;DTI;FLAIR;SPACE/VISTA;TSE/FSE;Other, specify Alphanumeric

Choose all that apply. For each pulse sequence checked, record the scan parameters in the table in question #6 - Scan parameters;In this row, for each column list each pulse sequence checked in question #3 (e.g., MPRAGE, FLAIR, DTI etc.)

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C19063 Imaging neurologic other data collected other text ImgNeuroOtherDataCollectedOTH The free-text field related to 'Imaging neurologic other data collected type' specifying other text. Other types of neuroimaging data that may have been collected during this scan visit The free-text field related to 'Imaging neurologic other data collected type' specifying other text. Other types of neuroimaging data that may have been collected during this scan visit Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-08-30 17:06:52.8 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator of whether an imaging contrast agent was used for the scan Indicator as to whether or not an imaging contrast agent was used for the scan Were contrast agents used? Yes;No Yes;No Alphanumeric

No additional instructions

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C15572 Imaging diffusion direction count ImgDiffusionDirCt Count of diffusion directions in the associated diffusion imaging study Count of diffusion directions in the associated diffusion imaging study # OF GRADIENT DIRECTIONS Numeric Values

For DTI only

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Magnetic Resonance (MR) Localization Imaging Imaging Diagnostics Assessments and Examinations

Free-Form Entry

CSV