CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 1 - 50 of 76
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C13959 | Microembolic signal measurement | MicroembolSignalMeasr | Indicates actual settings measurement for all categories (mm) | Indicates actual settings measurement for all categories (mm) | Settings | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C14030 | Vasospasm resistive index indicator | VasospasmRestistIndexInd | Indicates vasospasm resistive Index (RI) | Indicates vasospasm resistive Index (RI) | Resistive index | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14008 | Imaging window quality category | ImgWindowQualityCat | Indicates window quality category | Indicates window quality category | Insonation plane: | Temporal;Posterior;Orbital | Temporal;Posterior;Orbital | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14056 | Imaging depth measurement | ImgDepthMeasr | The depth measurement (mm) of imaging | The depth measurement (mm) of imagin | Depth | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter | |||||||
C08254 | Imaging visual analysis location performed type | ImgVisAnlysisLocPerfTyp | Type of location where visual analysis of the imaging data are performed | Type of location where visual analysis of the imaging data are performed | Read type | Central;Central read;Local - Site;Local read;Local report;Other, specify | Central;Central read;Local - Site;Local read;Local report;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2022-07-22 15:18:03.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13903 | Imaging interpretation site location | ImgInterpretSiteLoc | Indicates imaging interpretation site | Indicates imaging interpretation site | Interpretation site | Onsite;Offsite | Onsite;Offsite | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14020 | Sickle cell disease vessel anatomic site | SickleCellDisVesselAntmicSite | Indicates sickle cell vessel | Indicates sickle cell vessel | Vessel(s) | ICA;MCA;ACA;Other, specify | Internal carotid artery;Middle cerebral artery;Anterior carotid artery;Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13960 | High intensity transient signal hits vessel anatomic site | HighIntensTransSigHitAnatSite | Indicates high intensity transient signal hits vessel category | Indicates high intensity transient signal hits vessel category | Microembolic signals | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14031 | Vasospasm status | VasospasmStatus | Indicates vasospasm result | Indicates vasospasm result | Vasospasm | Abnormal;Normal | Abnormal;Normal | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14009 | Imaging window quality result | ImgWindowQualityReslt | Indicates window quality result for all categories | Indicates window quality result for all categories | Window quality | Fair;Excellent;Poor | Fair;Excellent;Poor | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18693 | Imaging contrast agent method other text | ImgContrastAgentMethodOTH | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C08255 | Imaging visual analysis blinded indicator | ImgVisAnlysisBlindInd | Indicator of whether the visual analysis was performed blinded to clinical data | Indicator of whether the visual analysis was performed blinded to clinical data | Reader blinded to clinical data | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Contains data elements collected when an imaging study is performed using angiography to examine the blood vessels of the body; there are separate sections to record arterial findings and venous findings. (Examples of CDEs included: Findings for each artery; TIMI scale individual vessel score; and Collateral grade) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13904 | Imaging interpretation offsite media type | ImgInterpretOffsiteMediaTyp | Indicates imaging offsite media type | Indicates imaging offsite media type | Indicate type | Video;Print;Digital | Video;Print;Digital | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14021 | Sickle cell disease blood flow velocity measurement | SickleCellVelBldFlowMeasr | The velocity measurement blood flow relative to sickle cell disease | The velocity measurement blood flow relative to sickle cell diseas | Velocity | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C13961 | High intensity transient signal hits present indicator | HighIntensTransSigHitPresInd | Indicates presence of high intensity transient signals hits | Indicates presence of high intensity transient signals hits | Microembolic signals | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14032 | Vasospasm severity grade | VasospasmSeverGrade | Indicates severity of vasospasm | Indicates severity of vasospasm | Severity | Mild;Moderate;Severe | Mild;Moderate;Severe | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14010 | Intracranial stenosis collateral vessel anatomic site | IntracrnStnoColltVsslAntmicSit | Indicates intracranial stenosis collateral vessel(s) | Indicates intracranial stenosis collateral vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;ACA;VA;PCA | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Anterior carotid artery;Vertebral artery;Posterior carotid artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18720 | Imaging visual analysis location performed type other text | ImgVisAnlysisLocPerfTypOTH | The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed | The free-text field related to 'Imaging visual analysis location performed type' specifying other text. Location where visual analysis of the imaging data are performed | Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-22 15:20:37.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator of whether an imaging contrast agent was used for the scan | Indicator as to whether or not an imaging contrast agent was used for the scan | Contrast Agent | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13905 | Imaging contrast agent method type | ImgContrastAgentMethodTyp | Indicates imaging contrast agent method of administration | Indicates imaging contrast agent method of administratio | Type | Bolus;Infusion;Other, specify | Bolus;Infusion;Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14022 | Sickle cell disease criterion result text | SickleCellCriterResltTxt | Indicates sickle cell criterion result | Indicates sickle cell criterion result | Criterion | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14000 | Extracranial stenosis present indicator | ExtracranStenPresInd | Indicates presence of extracranial stenosis | Indicates presence of extracranial stenosis | Extracranial stenosis | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14033 | Vasospasm vessel anatomic site | VasospasmVesselAntmicSite | Indicates vasospasm vessel(s) | Indicates vasospasm vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;ACA;VA | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Anterior cerebral artery;Vertebral artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14011 | Intracranial stenosis present indicator | IntracranStenosisPresentInd | Indicates presence of intracranial stenosis | Indicates presence of intracranial stenosis | Intracranial stenosis | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18888 | Imaging acquisition reason other text | ImgAcquisitionRsnOTH | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10931 | Imaging quality technically satisfactory status | ImgQualTechnSatisStat | Status related to whether the quality of the images was technically satisfactory | Status related to whether the quality of the images was technically satisfactory | Study technically satisfactory | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:51.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13942 | Imaging vessel category | ImgVesselCat | Indicates vessel category | Indicates vessel category | Vessels | M1;Insular M2;A1;ICA;P1;P2;EC ICA;Siphon;Vert;Basilar;Ophthalmic | M1;Insular M2;A1;Internal Carotid Artery (ICA);P1;P2;EC Internal Carotid Artery (ICA);Siphon;Vert;Basilar;Ophthalmic Artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14023 | Sickle cell disease diagnosis result | SickleCellDiagnosReslt | Indicates sickle cell diagnosis result | Indicates sickle cell diagnosis result | Diagnosis | Abnormal;Normal;Conditional | Abnormal;Normal;Conditional | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14001 | Extracranial stenosis type | ExtracranStenosisTyp | Indicates extracranial stenosis type | Indicates extracranial stenosis type | Extracranial stenosis | Collateral;Reduced upstroke;Reduced pulsatility index (Pi);VMR;Reduced velocity | Collateral;Reduced upstroke;Reduced pulsatility index (Pi);VMR;Reduced velocity | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14034 | Vasomotor response (VMR) vessel anatomic site | VMRVesselAntmicSite | Indicates vasomotor response (VMR) vessel type | Indicates vasomotor response (VMR) vessel type | Vessel | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar;MCA;Other, specify | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar;Middle cerebral artery;Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14012 | Intracranial stenosis peak systolic velocity (PSV) criterion result | IntracranStenoPSVCriterReslt | Indicates intracranial stenosis peak systolic velocity (PSV) criterion | Indicates intracranial stenosis peak systolic velocity (PSV) criterion | PSV criterion | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C18899 | Imaging brain death vessel anatomic other text | ImgBrainDeathVesseIAntmicOTH | The free-text field related to 'Imaging brain death vessel anatomic site' specifying other text. Indicates brain death vessel(s) | The free-text field related to 'Imaging brain death vessel anatomic site' specifying other text. Indicates brain death vessel(s) | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13245 | National Institutes of Health Stroke Scale (NIHSS) - severity total score | NIHSSSevTotalScore | The level of stroke severity as measured by the NIH Stroke Scale (NIHSS) scoring system (i.e., total of the subscale item scores) | The level of stroke severity as measured by the NIH Stroke Scale (NIHSS) scoring system (i.e., total of the subscale item scores | NIH Stroke Scale (NIHSS) at time of study: | Numeric Values |
A maximal score of 42 represents the most severe and devastating stroke. This element should be collected with the other elements of the NIH Stroke Scale (NIHSS). |
Brott, T., H.P. Adams Jr., C.P. Olinger, J.R. Marler, W.G. Barsan, J. Biller, J. Spilker, R. Holleran, R. Eberle, V. Hertzberg, M. Rorick, C.J. Moomaw, and M. Walker (1989) Measurements of acute cerebral infarction: a clinical examination scale. Stroke, 20, 964-970. http://stroke.ahajournals.org/content/20/7/864.full.pdf | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 42 | ||||||||
C13947 | Imaging peak velocity measurement | ImgPeakVelocityMeasr | Indicates peak velocity measurement (cm/sec) | Indicates peak velocity measurement (cm/sec) | Peak velocity | Numeric Values |
Indicate peak velocity in units of cm/sec |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C14024 | Vasospasm criterion value | VasoCriterionVal | Indicates vasospasm criterion value | Indicates vasospasm criterion value | Criterion | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14002 | Extracranial stenosis collateral artery anatomic site | ExtracranStenCollArtAntmicSite | The site of parallel arteries having extracranial stenosis | The site of parallel arteries having extracranial stenosi | Collateral | OA;ACA;VA | Ophthalmic artery;Anterior cerebral artery;Vertebral artery | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14035 | VMR response result | VMRResponseReslt | Indicates vasomotor response (VMR) response result | Indicates vasomotor response (VMR) response result | VMR | Abnormal;Normal | Abnormal;Normal | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14013 | Intracranial stenosis mean velocity criterion value | IntracranStenoMnVlctyCriterVal | Indicates intracranial stenosis mean velocity criterion | Indicates intracranial stenosis mean velocity criterion | Mean velocity criterion | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18900 | Intracranial stenosis collateral vessel anatomic other text | IntracrnStnoColltVsslAntmicOTH | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | The free-text field related to 'Intracranial stenosis collateral vessel anatomic site' specifying other text. Indicates intracranial stenosis collateral vessel(s) | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13750 | Imaging study ID number | ImgStudyIDNum | Unique identification number assigned to the study or assessment session | Unique identification number assigned to the study or assessment sessio | Study ID number | Alphanumeric |
Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13948 | Imaging mean blood velocity measurement | ImgMeanBloodVelocityMeasr | Indicates mean velocity measurement (cm/sec) of blood | Indicates mean velocity measurement (cm/sec) of blood | Mean velocity | Numeric Values |
Indicate mean velocity in units of cm/sec |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C14025 | Vasospasm Lindegaard ratio value | VasoLinegaardRatioVal | Indicates vasospasm lindegaard ratio result | Indicates vasospasm Lindegaard ratio result | Lindegaard ratio | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14003 | Imaging brain death present indicator | ImgBrainDeathPresInd | Indicates presence of brain death | Indicates presence of brain death | Brain death | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14036 | Breath-holding index result | BreathHoldingIndexReslt | Indicates Breath-holding index (BHI) result | Indicates breath-holding index (BHI) result | Breath-holding index (BHI) | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14014 | Intracranial stenosis other criteria result | IntracranStenoOthCriteriaReslt | Other criteria for intracranial stenosis | Other criteria for intracranial stenosis | Other | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C18901 | Sickle cell disease vessel anatomic other text | SickleCellDisVesselAntmicOTH | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Diagnostic;Post-treatment;Monitoring;Other, specify | Diagnostic;Post-treatment;Monitoring;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13949 | Imaging flow/probe direction type | ImgFlowProbDireTyp | Indicates flow/probe direction | Indicates flow/probe direction | Direction of Probe | Towards;Away from | Towards;Away from | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14026 | Intracranial pressure imaging result | ICPReslt | Indicates intracranial pressure (ICP) imaging result | Indicates vasospasm intracranial pressure (ICP) imaging result | Intracranial pressure | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter of mercury | |||||||
C14004 | Imaging brain death vessel anatomic site | ImgBrainDeathVesseIAntmicSite | Indicates brain death vessel(s) | Indicates brain death vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;ACA;VA;PCA;Ophthalmic artery | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Anterior carotid artery;Vertebral artery;Posterior carotid artery;Ophthalmic artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |