CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Vessel Imaging Transcranial Doppler (TCD)
Displaying 1 - 50 of 76
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C14003 | Imaging brain death present indicator | ImgBrainDeathPresInd | Indicates presence of brain death | Indicates presence of brain death | Brain death | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14036 | Breath-holding index result | BreathHoldingIndexReslt | Indicates Breath-holding index (BHI) result | Indicates breath-holding index (BHI) result | Breath-holding index (BHI) | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Diagnostic;Post-treatment;Monitoring;Other, specify | Diagnostic;Post-treatment;Monitoring;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14014 | Intracranial stenosis other criteria result | IntracranStenoOthCriteriaReslt | Other criteria for intracranial stenosis | Other criteria for intracranial stenosis | Other | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C18901 | Sickle cell disease vessel anatomic other text | SickleCellDisVesselAntmicOTH | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel | Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13949 | Imaging flow/probe direction type | ImgFlowProbDireTyp | Indicates flow/probe direction | Indicates flow/probe direction | Direction of Probe | Towards;Away from | Towards;Away from | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14026 | Intracranial pressure imaging result | ICPReslt | Indicates intracranial pressure (ICP) imaging result | Indicates vasospasm intracranial pressure (ICP) imaging result | Intracranial pressure | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter of mercury | |||||||
C14004 | Imaging brain death vessel anatomic site | ImgBrainDeathVesseIAntmicSite | Indicates brain death vessel(s) | Indicates brain death vessel(s) | Vessel(s) | ICA;Basilar;MCA;Other, specify;ACA;VA;PCA;Ophthalmic artery | Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Anterior carotid artery;Vertebral artery;Posterior carotid artery;Ophthalmic artery | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14037 | Imaging power M mode left middle cerebral artery result type | ImgPowerMModeLeftMCAResTyp | Indicates power M mode for left middle cerebral artery (MCA) result | Indicates power M mode for left middle cerebral artery (MCA) result | Left MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:28:20.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13899 | Imaging probe type text | ImgProbeTypTxt | The text describing the type of imaging probe | Describes imaging probe type | Type | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14015 | High intensity transient signal hits count | HighIntensTransSignalHitsCt | Numeric value counting the number of high intensity transient signals hits | Numeric value counting the number of high intensity transient signals hits | Number | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | ||||||||
C18902 | Vasospasm vessel anatomic other text | VasospasmVesselAntmicOTH | The free-text field related to 'Vasospasm vessel anatomic site' specifying other text. Indicates vasospasm vessel(s) | The free-text field related to 'Vasospasm vessel anatomic site' specifying other text. Indicates vasospasm vessel(s) | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13956 | High intensity transient signal hits duration | HighIntensTransSignalHitsDur | Indicates high intensity transient signal hits duration time (msec) | Indicates high intensity transient signal hits duration time (msec) | Duration time | Numeric Values |
Indicate duration time in units of msec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millisecond | |||||||
C14027 | Intracranial pressure (ICP) other measurement text | ICPOtherMeasrTxt | Indicates other method of measuring intracranial pressure (ICP) | Indicates other method of measuring intracranial pressure (ICP) | Other | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C01559 | Arterial partial pressure carbon dioxide value | ArterialPPCO2Val | Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) | Measurement of how much carbon dioxide is dissolved in the arterial blood and how well carbon dioxide is able to move out of the body (PaCO2) | Partial pressure of carbon dioxide (PCO2) | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-20 10:21:25.65 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 100 | millimeter of mercury | |||||||
C14005 | Imaging brain death diagnosis result | ImgBrainDeathDiagReslt | Indicates brain death diagnosis result | Indicates brain death diagnosis result | Brain death | Reversed Diastolic Flow;Systolic spike;No signals | Reversed Diastolic Flow;Systolic spike;No signals | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14038 | Imaging power M mode right middle cerebral artery result type | ImgPowerMModeRightMCAResTyp | Indicates power M mode for right middle cerebral artery (MCA) result | Indicates power M mode for right middle cerebral artery (MCA) result | Right MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:52:18.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13900 | Imaging probe frequency | ImgProbeFreq | Indicates imaging probe frequency (Hz) | Indicates imaging probe frequency (Hz) | Frequency | Numeric Values |
Indicate frequency in units of Hz |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz | |||||||||
C14016 | High intensity transient signal hits start time | HighIntensTransSigHitStartTime | Indicates high intensity transient signal hits start time | Indicates high intensity transient signal hits start time | Start Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18903 | Vasomotor response (VMR) vessel anatomic other text | VMRVesselAntmicOTH | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13957 | High intensity transient signal hits intensity value | HighIntensTransSignalHitsVal | Indicates high intensity transient signal hits intensity value (dB) | Indicates high intensity transient signal hits intensity value (dB) | Intensity | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
decibel | |||||||||
C14028 | Vasospasm present indicator | VasoPresInd | Indicates presence of vasospasm | Indicates presence of vasospasm | Vasospasm | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02411 | Laterality type | LatTyp | Laterality type relative to the anatomic site of the body examined or affected | Laterality type relative to the anatomic site of the body examined or affected | Specify laterality | Left;Right | Left;Right | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14006 | Imaging stenosis percentage value | ImgStenosisPercentageVal | Indicates stenosis percentage value | Indicates stenosis percentage value | Percent Stenosis | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 99 | percent | |||||||
C14051 | High intensity transient signal hits end time | HighIntensTransSigHitEndTime | Indicates high intensity transient signal hits end time | Indicates high intensity transient signal hits end time | End Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13901 | Imaging patient type | ImgPatientTyp | Indicates imaging patient type | Indicates imaging patient type | Patient type | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm | Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14017 | Microembolic signal unidirectional indicator | MicroembolSignalUnidirectInd | Indicates unidirectional microembolic signal | Indicates unidirectional microembolic signal | Unidirectional | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13958 | Microembolic signal settings type | MicroembolSignalSettingTyp | Indicates microembolic signal settings category | Indicates microembolic signal settings category | Settings | Leading cols;Trailing cols;Threshold;Rejection | Leading cols;Trailing cols;Threshold;Rejection | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14029 | Vasospasm posterior ratio result | VasoPosterRatioReslt | Indicates vasospasm posterior ratio result | Indicates vasospasm posterior ratio result | Posterior ratio | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 10 | ||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained | Date (and time, if applicable and known) the radiologic study was obtained | Date and time of study | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:51:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14007 | Imaging Transcranial Doppler (TCD) findings result type | ImgTCDFindResltTyp | Indicates Transcranial Doppler (TCD) findings | Indicates Transcranial Doppler (TCD) findings | Findings | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14052 | Hemoglobin measurement | HemoglobMeasr | The measurement for hemoglobin | The measurement for hemoglobi | Hemoglobin | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13902 | Imaging acute stroke study type | ImgAcutStokStudTyp | Indicates imaging acute stroke study type | Indicates imaging acute stroke study type | Indicate study type | Initial;Follow-up 1;Follow-up 2 | Initial;Follow-up 1;Follow-up 2 | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14019 | Sickle cell disease present indicator | SickleCellPresInd | Indicates presence of sickle cell | Indicates presence of sickle cell | Sickle cell | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13959 | Microembolic signal measurement | MicroembolSignalMeasr | Indicates actual settings measurement for all categories (mm) | Indicates actual settings measurement for all categories (mm) | Settings | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C14030 | Vasospasm resistive index indicator | VasospasmRestistIndexInd | Indicates vasospasm resistive Index (RI) | Indicates vasospasm resistive Index (RI) | Resistive index | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08254 | Imaging visual analysis location performed type | ImgVisAnlysisLocPerfTyp | Type of location where visual analysis of the imaging data are performed | Type of location where visual analysis of the imaging data are performed | Read type | Central;Central read;Local - Site;Local read;Local report;Other, specify | Central;Central read;Local - Site;Local read;Local report;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2022-07-22 15:18:03.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14008 | Imaging window quality category | ImgWindowQualityCat | Indicates window quality category | Indicates window quality category | Insonation plane: | Temporal;Posterior;Orbital | Temporal;Posterior;Orbital | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14056 | Imaging depth measurement | ImgDepthMeasr | The depth measurement (mm) of imaging | The depth measurement (mm) of imagin | Depth | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter | |||||||
C13903 | Imaging interpretation site location | ImgInterpretSiteLoc | Indicates imaging interpretation site | Indicates imaging interpretation site | Interpretation site | Onsite;Offsite | Onsite;Offsite | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14020 | Sickle cell disease vessel anatomic site | SickleCellDisVesselAntmicSite | Indicates sickle cell vessel | Indicates sickle cell vessel | Vessel(s) | ICA;MCA;ACA;Other, specify | Internal carotid artery;Middle cerebral artery;Anterior carotid artery;Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13960 | High intensity transient signal hits vessel anatomic site | HighIntensTransSigHitAnatSite | Indicates high intensity transient signal hits vessel category | Indicates high intensity transient signal hits vessel category | Microembolic signals | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14031 | Vasospasm status | VasospasmStatus | Indicates vasospasm result | Indicates vasospasm result | Vasospasm | Abnormal;Normal | Abnormal;Normal | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08255 | Imaging visual analysis blinded indicator | ImgVisAnlysisBlindInd | Indicator of whether the visual analysis was performed blinded to clinical data | Indicator of whether the visual analysis was performed blinded to clinical data | Reader blinded to clinical data | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Contains data elements collected when an imaging study is performed using angiography to examine the blood vessels of the body; there are separate sections to record arterial findings and venous findings. (Examples of CDEs included: Findings for each artery; TIMI scale individual vessel score; and Collateral grade) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14009 | Imaging window quality result | ImgWindowQualityReslt | Indicates window quality result for all categories | Indicates window quality result for all categories | Window quality | Fair;Excellent;Poor | Fair;Excellent;Poor | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18693 | Imaging contrast agent method other text | ImgContrastAgentMethodOTH | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | The free-text field related to 'Imaging contrast agent method type' specifying other text. Indicates imaging contrast agent method of administration | Other, specify | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13904 | Imaging interpretation offsite media type | ImgInterpretOffsiteMediaTyp | Indicates imaging offsite media type | Indicates imaging offsite media type | Indicate type | Video;Print;Digital | Video;Print;Digital | Alphanumeric |
Contains data elements collected when an imaging study is performed using carotid ultrasound to examine the two large arteries in the neck; there are separate sections to record findings from B-mode and color flow imaging. (Examples of CDEs included: Severity of plaque; Percent stenosis; and Mean lumen diameter) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14021 | Sickle cell disease blood flow velocity measurement | SickleCellVelBldFlowMeasr | The velocity measurement blood flow relative to sickle cell disease | The velocity measurement blood flow relative to sickle cell diseas | Velocity | Numeric Values |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C13961 | High intensity transient signal hits present indicator | HighIntensTransSigHitPresInd | Indicates presence of high intensity transient signals hits | Indicates presence of high intensity transient signals hits | Microembolic signals | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14032 | Vasospasm severity grade | VasospasmSeverGrade | Indicates severity of vasospasm | Indicates severity of vasospasm | Severity | Mild;Moderate;Severe | Mild;Moderate;Severe | Alphanumeric |
These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial Doppler (TCD) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |