CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Perfusion and Penumbral Imaging
Displaying 1 - 31 of 31
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C58814 | Imaging magnetic resonance based identification penumbra method other text | ImgMRBasedIDPenumbraMethOTH | The free-text field related to 'Imaging magnetic resonance based identification penumbra method type' specifying other text | The free-text field related to 'Imaging magnetic resonance based identification penumbra method type' specifying other tex | Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-14 18:22:11.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C58815 | Imaging perfusion computed tomography based identification penumbra method other text | ImgPCTBaseIDPenMethdOTH | The free-text field related to 'Imaging perfusion computed tomography based identification penumbra method type' specifying other text | The free-text field related to 'Imaging perfusion computed tomography based identification penumbra method type' specifying other tex | Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-14 18:36:11.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13873 | Imaging perfusion computed tomography based identification perfusion defect volume type | ImgPCTBaseIDPerDefVolTyp | Indicates CT (PCT) based identification of perfusion defect volume type | Indicates CT (PCT) based identification of perfusion defect volume type | Volume Type | Mean transit time lesion volume;Time to peak lesion volume;Time-to-max (Tmax) lesion volume;Regional cerebral blood flow (rCBF) | Mean transit time lesion volume;Time to peak lesion volume;Time-to-max (Tmax) lesion volume;Regional cerebral blood flow (rCBF) | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13863 | Imaging magnetic resonance based identification perfusion defect threshold type | ImgMRBsdIDPerfusnDefThrshldTyp | Indicates MR based identification of perfusion defect threshold type used to delineate abnormality | Indicates MR based identification of perfusion defect threshold type used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13874 | Imaging perfusion computed tomography based identification perfusion defect threshold type | ImgPCTBaseIDPerDefThTyp | Indicates PCT based identification of perfusion defect threshold type used to delineate abnormality | Indicates PCT based identification of perfusion defect threshold type used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02494 | Imaging study date and time | ImgStdyDateTime | Date (and time, if applicable and known) the radiologic study was obtained | Date (and time, if applicable and known) the radiologic study was obtained | Date and time of study | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Duhaime AC, Gean AD, Haacke EM, Hicks R, Wintermark M, Mukherjee P, Brody D, Latour L, Riedy G; Common Data Elements Neuroimaging Working Group Members, Pediatric Working Group Members. Common data elements in radiologic imaging of traumatic brain injury. Arch Phys Med Rehabil. 2010 Nov;91(11):1661-6. [DOI: 10.1016/j.apmr.2010.07.238] | Adult;Pediatric | Supplemental-Highly Recommended | 3.10 | 2024-02-29 15:51:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13864 | Imaging magnetic resonance based identification perfusion defect value | ImgMRBasedIDPerfusnDefVal | Value of MR based identification of perfusion defect abnormality | Value of MR based identification of perfusion defect abnormality | Value of threshold used to delineate abnormality | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13875 | Imaging perfusion computed tomography based identification perfusion defect value | ImgPCTBaseIDPerDefVal | Value of PCT based identification of perfusion defect abnormality | Value of PCT based identification of perfusion defect abnormality | Value of threshold used to delineate abnormality | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13245 | National Institutes of Health Stroke Scale (NIHSS) - severity total score | NIHSSSevTotalScore | The level of stroke severity as measured by the NIH Stroke Scale (NIHSS) scoring system (i.e., total of the subscale item scores) | The level of stroke severity as measured by the NIH Stroke Scale (NIHSS) scoring system (i.e., total of the subscale item scores | NIH Stroke Scale (NIHSS) at time of scan | Numeric Values |
A maximal score of 42 represents the most severe and devastating stroke. This element should be collected with the other elements of the NIH Stroke Scale (NIHSS). |
Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 42 | |||||||||
C13865 | Imaging magnetic resonance based identification perfusion defect volume measurement | ImgMRBasedIDPerfusnDefVolMeasr | Indicates MR based identification of perfusion defect volume | Indicates MR based identification of perfusion defect volume | Defect volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13876 | Imaging perfusion computed tomography based identification perfusion defect volume measurement | ImgPCTBaseIDPerDefVolMeasr | Indicates PCT based identification of perfusion defect volume | Indicates PCT based identification of perfusion defect volume | Defect volume (ml) | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13750 | Imaging study ID number | ImgStudyIDNum | Unique identification number assigned to the study or assessment session | Unique identification number assigned to the study or assessment sessio | Study ID number | Alphanumeric | No references available | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C13866 | Imaging magnetic resonance based identification penumbra method type | ImgMRBasedIDPenumbraMethTyp | Indicates MR based identification of penumbra method used for penumbra calculation | Indicates MR based identification of penumbra method used for penumbra calculation | Method used for penumbra calculation | DWI-CBF mismatch;DWI-MTT mismatch;DWI-TTP mismatch;DWI-Tmax mismatch;Multiparametric model;Other, specify | DWI-CBF mismatch;DWI-MTT mismatch;DWI-TTP mismatch;DWI-Tmax mismatch;Multiparametric model;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13877 | Imaging perfusion computed tomography based identification penumbra method type | ImgPCTBaseIDPenMethdTyp | Indicates PCT based identification of penumbra method used for penumbra calculation | Indicates PCT based identification of penumbra method used for penumbra calculation | Method used for penumbra calculation | Multiparametric model;CBV-CBF mismatch;CBV-MTT mismatch;CBV-TTP mismatch;CBV-Tmax mismatch;Other, specify | Multiparametric model;Cerebral blood volume-Cerebral blood flow mismatch;Cerebral blood volume-mean transit time mismatch;Cerebral blood volume-time to peak mismatch;Cerebral blood volume-Tmax mismatch;Other, specify | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Diagnostic;Post-treatment;Monitoring;Other, specify | Diagnostic;Post-treatment;Monitoring;Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13867 | Imaging magnetic resonance based identification penumbra volume measurement | ImgMRBasedIDPenumbraVolMeasr | Indicates MR based identification of penumbra volume for all the methods selected | Indicates MR based identification of penumbra volume for all the methods selected | Volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13878 | Imaging perfusion computed tomography based identification penumbra volume measurement | ImgPCTBaseIDPenVolMeasr | Indicates PCT based identification of penumbra volume for all the methods selected | Indicates PCT based identification of penumbra volume for all the methods selected | Volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13857 | Imaging magnetic resonance based identification core volume type | ImgMRBasedIDCoreVolumeTyp | Indicates magnetic resonance based identification of core volume type | Indicates magnetic resonance based identification of core volume type | Volume Type | Diffusion Weighted Imaging (DWI) volume;Apparent Diffusion Coefficient (ADC) volume;Other, specify | Diffusion Weighted Imaging (DWI) volume;Apparent Diffusion Coefficient (ADC) volume;Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13868 | Imaging perfusion computed tomography based identification core threshold type | ImgPCTBaseIDCoreThTyp | Indicates perfusion CT (PCT) based identification of core threshold used to delineate abnormality | Indicates perfusion CT (PCT) based identification of core threshold used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14018 | Imaging perfusion computed tomography based identification core defect volume measurement | ImgPCTBaseIDCoreDefVolMeasr | Indicates perfusion CT (PCT) based identification of core defect volume | Indicates perfusion CT (PCT) based identification of core defect volume | Defect volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13858 | Imaging magnetic resonance based identification core threshold type | ImgMRBasedIDCoreThresholdTyp | Indicates MR based identification of core threshold used to delineate abnormality | Indicates MR based identification of core threshold used to delineate abnormality | Threshold used to delineate abnormality | Absolute;Relative | Absolute;Relative | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13869 | Imaging perfusion computed tomography based identification core value result | ImgPCTBaseIDCoreValReslt | Result of perfusion CT (PCT) based identification of core value of abnormality | Result of perfusion CT (PCT) based identification of core value of abnormality | Value of threshold used to delineate abnormality | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C18888 | Imaging acquisition reason other text | ImgAcquisitionRsnOTH | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | The free-text field related to 'Imaging acquisition reason' specifying other text. Describes why the imaging study was performed | Other, specify | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13859 | Imaging magnetic resonance based identification core value abnormality result | ImgMRBasedIDCoreValAbnrmlyRes | Result of magnetic resonance based identification of core value of abnormality | Result of magnetic resonance based identification of core value of abnormality | Value of threshold used to delineate abnormality | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C13870 | Imaging perfusion computed tomography based identification core method type | ImgPCTBaseIDCoreMethdTyp | Indicates perfusion CT (PCT) based identification of core method used for penumbra calculation | Indicates perfusion CT (PCT) based identification of core method used for penumbra calculation | Method used for penumbra calculation | Multiparametric model;CBV | Multiparametric model;Cerebral blood volume | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
|||||||||
C18890 | Imaging magnetic resonance based identification core volume other text | ImgMRBasedIDCoreVolumeOTH | The free-text field related to 'Imaging magnetic resonance based identification core volume type' specifying other text. Indicates magnetic resonance based identification of core volume type | The free-text field related to 'Imaging magnetic resonance based identification core volume type' specifying other text. Indicates magnetic resonance based identification of core volume type | Other, specify | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13860 | Imaging magnetic resonance based identification core defect volume measurement | ImgMRBasedIDCoreDefectVolMeasr | Indicates MR based identification of core defect volume measurement | Indicates MR based identification of core defect volume measurement | Defect volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
milliliter | |||||||||
C13871 | Imaging perfusion computed tomography based identification core volume measurement | ImgPCTBaseIDCoreVolMeasr | Indicates perfusion CT (PCT) based identification of core volume for all the methods used | Indicates perfusion CT (PCT) based identification of core volume for all the methods used | Volume | Numeric Values |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | milliliter | |||||||
C13861 | Imaging magnetic resonance based identification perfusion defect method type | ImgMRBasedIDPerfusnDefMethTyp | Indicates MR based identification of perfusion defect - method used for perfusion processing | Indicates MR based identification of perfusion defect - method used for perfusion processing | Method used for perfusion processing | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13872 | Imaging perfusion computed tomography based identification perfusion defect correction method type | ImgPCTBaseIDPerDefCorMethdTyp | Indicates PCT based identification of perfusion defect method used for perfusion processing | Indicates PCT based identification of perfusion defect correction method used for perfusion processing | Method used for perfusion processing | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | No deconvolution;Deconvolution without delay correction;Deconvolution with delay correction | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13862 | Imaging magnetic resonance based identification perfusion defect volume type | ImgMRBasedIDPerfusnDefVolTyp | Indicates MR based identification of perfusion defect volume type | Indicates MR based identification of perfusion defect volume type | Volume Type | Cerebral blood flow (CBV) defect volume;Mean transit time lesion volume;Time to peak lesion volume;Time to maximum (Tmax) lesion volume | Cerebral blood flow (CBV) defect volume;Mean transit time lesion volume;Time to peak lesion volume;Time to maximum (Tmax) lesion volume | Alphanumeric |
Contains data elements collected when an imaging study is performed to measure perfusion and penumbra; there are separate sections to record MRI findings and CT findings. (Examples of CDEs included: Diffusion weighted imaging volume; Time to peak lesion volume; and Cerebral blood flow defect volume) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Perfusion and Penumbral Imaging | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |