CDE Detailed Report
Disease: system
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 56 of 56
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 56 of 56
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C10959 | Spectroscopy spectral bandwidth value | SpectroSpectralBandwidthVal | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Bandwidth | Numeric Values |
Answer should be recorded in Hz/Pixel |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C12511 | Imaging post-processing raw data save indicator | ImgPostprocessRawDataSaveInd | Indicator of whether raw data was saved in post processing | Indicator of whether raw data was saved in post processing | Post processing d. Raw Data Saved | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:51:50.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | RF Coils Number of Channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17945 | Spectroscopy sequence parameter PRESS asymmetry TE2 value | SpectroSeqParamPRESSAsymTE2Val | Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported | Value, in ms, of echo time (TE) 2 for an asymmetric PRESS sequence if used in the scan being reported | Spectroscopy b Spectroscopy sequence parameters For PRESS is it symmetric or asymmetric? Asymmetric TE2 | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-28 13:09:35.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10960 | Spectroscopy PRESS symmetry type | SpectPRESSSymTyp | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | Spectroscopy d Water suppression | Symmetric;Asymmetric | Symmetric (TE = TE1 + TE2, TE1 = TE2);Asymmetric (TE1 =/= TE2) | Alphanumeric |
Answer should be recorded in milliseconds |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |