CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C10948 | Imaging field of view axis 3 measurement | ImgFieldViewAxis3Measr | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | z-direction (3D) | Numeric Values |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C12165 | Imaging water suppression sequence differences result text | ImgWaterSupressSeqDiffResltTxt | Text description of any differences in sequence parameters between water reference data and water suppression data | Text description of any differences in sequence parameters between water reference data and water suppression data | Spectroscopy e Water reference data acquisition performed in addition to water suppression acquisition Note any differences in sequence parameters from water suppressed | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C17941 | Spectroscopy geometry voxel slice size inferior superior value | SpectroGeomSizeInfSupVal | Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported | Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported | Spectroscopy c Geometry ii. Voxel or slice size: inferior superior | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Anatomical Reference Image TE | Numeric Values |
Answer should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.20 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C17953 | Imaging other nuclei text | ImgOthNucleiTxt | Text identification of unlisted nuclei in the image being reported | Text identification of unlisted nuclei in the image being reported | Nuclei Other | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C10952 | Spectroscopy water suppression type | SpectroWaterSupressMethodTyp | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Spectroscopy d Water suppression If yes | CHESS;Other, specify | CHESS;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy (MRS) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |