CDE Detailed Report

Disease: Spinal Muscular Atrophy
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Imaging (MRI)

Displaying 1 - 50 of 50
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes Duration of the imaging scan in minutes Total acquisition time Numeric Values

Answer should be recorded in minutes

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C17811 Imaging phase partial Fourier value ImgPhasPartialFourierVal Value of the phase partial Fourier ratio, if used in imaging acquisition Value of the phase partial Fourier ratio, if used in imaging acquisition Partial Fourier - if Yes, specify Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10587 Imaging echo spacing value ImgEchoSpcVal Measurement, in milliseconds, of the echo spacing used in diffusion acquisition Measurement, in milliseconds, of the echo spacing used in diffusion acquisitio Echo spacing Numeric Values

Answer should be recorded in milliseconds (ms). Must be answered with Echo Train Length, if Yes is answered for Fast Imaging.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10927 Imaging inversion time duration ImgInversionTimeDur Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence Inversion Time (TI) Numeric Values

Only answered if SPIR is answered for 'Method Used' and if 'Yes' is answered for 'FLAIR sequence'. Inversion Time (TI) should be recorded in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:46.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) Slice thickness Numeric Values

Answer should be recorded in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C17925 Imaging contrast agent dose ImgContrastAgentDose Dosage of the contrast agent used Dosage of the contrast agent used Dosage Numeric Values No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:39.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10588 Imaging echo train length measurement ImgEchoTrainLngthMeasr Measurement of the echo train length used in imaging acquisition Measurement of the echo train length used in imaging acquisition Echo train length Numeric Values

Must be answered with Echo Spacing, if Yes is answered for Fast Imaging and if 'Yes' is answered for 'T2 measurement'.

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C12508 Imaging radio frequency coil function type ImgRFCoilFunctTyp The function of the radio frequency (RF) coil used The function of the RF coil used Transmit Tx and or Receive Rx Tx;Rx;Tx/Rx Transmit;Receive;Transmit/Receive Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08245 Imaging slice count ImgSliceCt Count representing the total number of single image planes captured during imaging acquisition Count representing the total number of single image planes captured during imaging acquisition Number of slices Numeric Values

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18689 Imaging anatomic site other text ImgAnatSiteOTH The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.10 2024-02-29 15:53:09.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10591 Imaging phase encode direction text ImgPhasEncdeDirctTxt Text description of the phase encode direction used in imaging technique acquisition Text description of the phase encode direction used in imaging technique acquisition Phase encode direction Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02495 Imaging scanner strength value type ImgScannerStrgthValTyp Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Magnetic Field Strength of Scanner Used 1.5T;3.0T;4.0T;7.0T;Other, specify 1.5T;3.0T;4.0T;7.0T;Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:31.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12509 Imaging radio frequency coil category ImgRFCoilCat Type of radio frequency (RF) coil(s) category used for the body part scanned Type of RF coil(s) category used for the body part scanned Type of coil Surface;Volume Surface;Volume Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18696 Imaging dimension other text ImgDimensionOTH The free-text field related to 'Imaging dimension type' specifying other text. Type of imaging dimension used The free-text field related to 'Imaging dimension type' specifying other text. Type of imaging dimension used Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10566 Imaging radio frequency coil name ImgRFCoilName Name of the radio frequency (RF) coil(s) used for the body part scanned Name of the RF coil(s) used for the body part scanned Name of coil Alphanumeric

Specify the name of the RF coil

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10592 Imaging flow compensation indicator ImgFlowCompnsatnInd Indicator of whether flow compensation was used in imaging acquisition Indicator of whether flow compensation was used in imaging acquisition Flow compensation used Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02496 Imaging scanner manufacturer name ImgScannerManufName Name of manufacturer of imaging scanner Name of manufacturer of imaging scanner Name of the scanner manufacturer GE;Siemens;Philips;Toshiba;Other, specify GE;Siemens;Philips;Toshiba;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C12536 Imaging dimension type ImgDimensionTyp Type of imaging dimension used Type of imaging dimension used Scan dimension 2D;3D 2D;3D Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18697 Imaging fat signal suppressor used method other text ImgFatSignalSupprsUseMethdOTH The free-text field related to 'Imaging fat signal suppressor used method type' specifying other text. Type of method used to suppress fat signal in imaging acquisition The free-text field related to 'Imaging fat signal suppressor used method type' specifying other text. Type of method used to suppress fat signal in imaging acquisition Other, specify Alphanumeric

Only answered if Yes is answered for 'Fat signal suppressed'

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10568 Imaging radio frequency coil channel count ImgRFCoilChannelCt Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Number of channels 1;8;12 channels;16;24;32 channels;Other, specify Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10593 Imaging fat signal suppressed indicator ImgFatSignalSuppressedInd Indicator as to whether or not fat signal was suppressed in imaging acquisition Indicator as to whether or not fat signal was suppressed in imaging acquisition Fat signal suppressed Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02498 Imaging scanner software version number text ImgScannerSftwrVrsnNumTxt Free-text field specifying the version number of the imaging scanner software Free-text field specifying the version number of the imaging scanner software Name of the scanner software and its version number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12537 Imaging fat signal suppressor used method type ImgFatSignalSupprsUseMethdTyp Type of method used to suppress fat signal in imaging acquisition Type of method used to suppress fat signal in imaging acquisition If yes method used SPAIR;SPIR;Other, specify SPAIR;SPIR;Other, specify Alphanumeric

Only answered if Yes is answered for 'Fat signal suppressed'

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18703 Imaging parallel acquisition used other text ImgParallelAcquistionMethodOTH The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator of whether an imaging contrast agent was used for the scan Indicator as to whether or not an imaging contrast agent was used for the scan Contrast agent Yes;No Yes;No Alphanumeric

Choose one. If yes, record the name of the contrast agent and its dosage.

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10594 Imaging parallel acquisition used indicator ImgParallelAcquistionUsedInd Indicator of whether a parallel acquisition method is used in imaging acquisition Indicator of whether a parallel acquisition method is used in imaging acquisition Parallel acquisition used Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name of the scanner software and its version number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C12538 Imaging fast indicator ImgFastInd Indicator of whether or not fast imaging was used Indicator of whether or not fast imaging was used Fast Imaging Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18714 Imaging radio frequency coil channel count other text ImgRFCoilChannelCtOTH The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan Other, specify Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 2.00 2022-06-29 16:40:00.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition In plane resolution Numeric Values

Answer should be recorded as a dimension (AAxAAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
C10595 Imaging parallel acquisition used type ImgParallelAcquistionMethodTyp Type of the parallel acquisition method used in imaging acquisition Type of the parallel acquisition method used in imaging acquisitio If yes, method used GRAPPA;SENSE;Other, specify Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA);Sensitivity Encoding SENSE;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Repetition time TR Numeric Values

Answer should be recorded in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12539 Imaging fluid attenuated inversion recovery sequence indicator ImgFLAIRSeqInd Indicator of whether FLAIR (fluid attenuated inversion recovery) sequence was used to remove the effects of fluid from the resulting images Indicator of whether FLAIR (fluid attenuated inversion recovery) sequence was used to remove the effects of fluid from the resulting images FLAIR sequence Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18716 Imaging scanner manufacturer name other text ImgScannerManufNameOTH The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-06-28 13:09:35.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10583 Imaging base resolution value ImgBaseResolutionVal Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI) Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI Base Resolution Numeric Values

Answer should be recorded in points

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

point
C10596 Imaging slice over sampling value ImgSliceOverSampVal Value of the slice over sampling (as a percentage) used in imaging acquisition Value of the slice over sampling (as a percentage) used in imaging acquisition Slice over sampling Numeric Values

Answer should be recorded as a percent (%)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Echo time (TE) Numeric Values

Answer should be recorded in milliseconds (ms)

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C12540 Imaging T2 measurement indicator ImgT2MeasrInd Indicator of whether T2 measurement was used Indicator of whether T2 measurement was used T2 measurement Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10584 Imaging phase resolution percentage value ImgPhasResltnPercentVal The value in percent of the phase resolution used in imaging acquisition The value in percent of the phase resolution used in imaging acquisition Phase resolution Numeric Values

Must be answered with Partial Fourier, if Yes is answered for Fast Imaging

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

percent
C10682 Imaging anatomic site ImgAnatSite Anatomic site of body part or anatomy scanned in the imaging study Anatomic site of body part or anatomy scanned in the imaging study Body part scanned Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:53:09.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08240 Imaging flip angle measurement ImgFlipAngleMeasr Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle Measurement of the angle, in degrees over which the radio frequency changes proton spin angle Flip angle Numeric Values

Answer should be recorded in degrees

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

degree
C12541 Imaging contrast agent injection time ImgContrastAgentInjctnTime Time contrast medium was administered Time contrast medium was administered Time of injection Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18719 Imaging slice orientation type other text ImgSliceOrientTypOTH The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 15:08:41.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10585 Imaging phase partial Fourier indicator ImgPhasPartialFourierInd Indicator of whether phase partial Fourier was used Indicator of whether phase partial Fourier was used Partial Fourier Yes;No Yes;No Alphanumeric

Must be answered with Phase Resolution, if Yes is answered for Fast Imaging

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10685 Imaging slice orientation type ImgSliceOrientTyp Type of slice orientation used in imaging acquisition Type of slice orientation used in imaging acquisition Slice Orientation Axial;Coronal;Sagittal;Oblique Axial;Coronal;Sagittal;Oblique Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:40.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Field of view Numeric Values

Answer should be recorded as a dimension (AAxAAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17798 Imaging contrast agent name ImgContrastAgentName Name of imaging contrast agent used Name of imaging contrast agent used If yes, name of the contrast Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10586 Imaging bandwidth value ImgBandwidthVal Value, in Hertz per pixel, of bandwidth used in imaging acquisition Value, in Hertz per pixel, of bandwidth used in imaging acquisitio Band width Numeric Values

Answer should be recorded in Hx/Pixel

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz per pixel
C10837 Imaging gap between slices measurement ImgGapBetwnSlicesMeasr Measurement of the gap between slices used in imaging acquisition Measurement of the gap between slices used in imaging acquisition Gap between slices Numeric Values

Answer should be recorded in millimeters squared (mm) or % (for 2D acquisition)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter