CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Imaging (MRI)
Displaying 1 - 50 of 50
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C08242 | Imaging acquisition duration | ImgAcquisitionDur | Duration of the imaging scan in minutes | Duration of the imaging scan in minutes | Total acquisition time | Numeric Values |
Answer should be recorded in minutes |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
minute | |||||||||
C17811 | Imaging phase partial Fourier value | ImgPhasPartialFourierVal | Value of the phase partial Fourier ratio, if used in imaging acquisition | Value of the phase partial Fourier ratio, if used in imaging acquisition | Partial Fourier - if Yes, specify | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10587 | Imaging echo spacing value | ImgEchoSpcVal | Measurement, in milliseconds, of the echo spacing used in diffusion acquisition | Measurement, in milliseconds, of the echo spacing used in diffusion acquisitio | Echo spacing | Numeric Values |
Answer should be recorded in milliseconds (ms). Must be answered with Echo Train Length, if Yes is answered for Fast Imaging. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C10927 | Imaging inversion time duration | ImgInversionTimeDur | Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence | Duration of the time period between the 180 degree inversion pulse and the 90 degree excitation pulse in an Inversion Recovery pulse sequence | Inversion Time (TI) | Numeric Values |
Only answered if SPIR is answered for 'Method Used' and if 'Yes' is answered for 'FLAIR sequence'. Inversion Time (TI) should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:46.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C08244 | Imaging slice thickness value | ImgSliceThicknessVal | Value of the thickness of the slice measured in millimeters (mm) | Value of the thickness of the slice measured in millimeters (mm) | Slice thickness | Numeric Values |
Answer should be recorded in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 99 | millimeter | |||||||
C17925 | Imaging contrast agent dose | ImgContrastAgentDose | Dosage of the contrast agent used | Dosage of the contrast agent used | Dosage | Numeric Values | No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:39.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10588 | Imaging echo train length measurement | ImgEchoTrainLngthMeasr | Measurement of the echo train length used in imaging acquisition | Measurement of the echo train length used in imaging acquisition | Echo train length | Numeric Values |
Must be answered with Echo Spacing, if Yes is answered for Fast Imaging and if 'Yes' is answered for 'T2 measurement'. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C12508 | Imaging radio frequency coil function type | ImgRFCoilFunctTyp | The function of the radio frequency (RF) coil used | The function of the RF coil used | Transmit Tx and or Receive Rx | Tx;Rx;Tx/Rx | Transmit;Receive;Transmit/Receive | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08245 | Imaging slice count | ImgSliceCt | Count representing the total number of single image planes captured during imaging acquisition | Count representing the total number of single image planes captured during imaging acquisition | Number of slices | Numeric Values |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18689 | Imaging anatomic site other text | ImgAnatSiteOTH | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.10 | 2024-02-29 15:53:09.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10591 | Imaging phase encode direction text | ImgPhasEncdeDirctTxt | Text description of the phase encode direction used in imaging technique acquisition | Text description of the phase encode direction used in imaging technique acquisition | Phase encode direction | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C02495 | Imaging scanner strength value type | ImgScannerStrgthValTyp | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Magnetic Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify | 1.5T;3.0T;4.0T;7.0T;Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:31.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C12509 | Imaging radio frequency coil category | ImgRFCoilCat | Type of radio frequency (RF) coil(s) category used for the body part scanned | Type of RF coil(s) category used for the body part scanned | Type of coil | Surface;Volume | Surface;Volume | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18696 | Imaging dimension other text | ImgDimensionOTH | The free-text field related to 'Imaging dimension type' specifying other text. Type of imaging dimension used | The free-text field related to 'Imaging dimension type' specifying other text. Type of imaging dimension used | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10566 | Imaging radio frequency coil name | ImgRFCoilName | Name of the radio frequency (RF) coil(s) used for the body part scanned | Name of the RF coil(s) used for the body part scanned | Name of coil | Alphanumeric |
Specify the name of the RF coil |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10592 | Imaging flow compensation indicator | ImgFlowCompnsatnInd | Indicator of whether flow compensation was used in imaging acquisition | Indicator of whether flow compensation was used in imaging acquisition | Flow compensation used | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02496 | Imaging scanner manufacturer name | ImgScannerManufName | Name of manufacturer of imaging scanner | Name of manufacturer of imaging scanner | Name of the scanner manufacturer | GE;Siemens;Philips;Toshiba;Other, specify | GE;Siemens;Philips;Toshiba;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C12536 | Imaging dimension type | ImgDimensionTyp | Type of imaging dimension used | Type of imaging dimension used | Scan dimension | 2D;3D | 2D;3D | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18697 | Imaging fat signal suppressor used method other text | ImgFatSignalSupprsUseMethdOTH | The free-text field related to 'Imaging fat signal suppressor used method type' specifying other text. Type of method used to suppress fat signal in imaging acquisition | The free-text field related to 'Imaging fat signal suppressor used method type' specifying other text. Type of method used to suppress fat signal in imaging acquisition | Other, specify | Alphanumeric |
Only answered if Yes is answered for 'Fat signal suppressed' |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10593 | Imaging fat signal suppressed indicator | ImgFatSignalSuppressedInd | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Fat signal suppressed | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02498 | Imaging scanner software version number text | ImgScannerSftwrVrsnNumTxt | Free-text field specifying the version number of the imaging scanner software | Free-text field specifying the version number of the imaging scanner software | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C12537 | Imaging fat signal suppressor used method type | ImgFatSignalSupprsUseMethdTyp | Type of method used to suppress fat signal in imaging acquisition | Type of method used to suppress fat signal in imaging acquisition | If yes method used | SPAIR;SPIR;Other, specify | SPAIR;SPIR;Other, specify | Alphanumeric |
Only answered if Yes is answered for 'Fat signal suppressed' |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18703 | Imaging parallel acquisition used other text | ImgParallelAcquistionMethodOTH | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator of whether an imaging contrast agent was used for the scan | Indicator as to whether or not an imaging contrast agent was used for the scan | Contrast agent | Yes;No | Yes;No | Alphanumeric |
Choose one. If yes, record the name of the contrast agent and its dosage. |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10594 | Imaging parallel acquisition used indicator | ImgParallelAcquistionUsedInd | Indicator of whether a parallel acquisition method is used in imaging acquisition | Indicator of whether a parallel acquisition method is used in imaging acquisition | Parallel acquisition used | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name of the scanner software and its version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C12538 | Imaging fast indicator | ImgFastInd | Indicator of whether or not fast imaging was used | Indicator of whether or not fast imaging was used | Fast Imaging | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18714 | Imaging radio frequency coil channel count other text | ImgRFCoilChannelCtOTH | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Other, specify | Alphanumeric |
Answer for each RF coil named |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-29 16:40:00.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10576 | Imaging in plane resolution axis 1 measurement | ImgInPlaneRsltnAxis1Measr | Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition | Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition | In plane resolution | Numeric Values |
Answer should be recorded as a dimension (AAxAAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter | |||||||||
C10595 | Imaging parallel acquisition used type | ImgParallelAcquistionMethodTyp | Type of the parallel acquisition method used in imaging acquisition | Type of the parallel acquisition method used in imaging acquisitio | If yes, method used | GRAPPA;SENSE;Other, specify | Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA);Sensitivity Encoding SENSE;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Repetition time TR | Numeric Values |
Answer should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C12539 | Imaging fluid attenuated inversion recovery sequence indicator | ImgFLAIRSeqInd | Indicator of whether FLAIR (fluid attenuated inversion recovery) sequence was used to remove the effects of fluid from the resulting images | Indicator of whether FLAIR (fluid attenuated inversion recovery) sequence was used to remove the effects of fluid from the resulting images | FLAIR sequence | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-28 13:09:35.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10583 | Imaging base resolution value | ImgBaseResolutionVal | Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI) | Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI | Base Resolution | Numeric Values |
Answer should be recorded in points |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
point | |||||||||
C10596 | Imaging slice over sampling value | ImgSliceOverSampVal | Value of the slice over sampling (as a percentage) used in imaging acquisition | Value of the slice over sampling (as a percentage) used in imaging acquisition | Slice over sampling | Numeric Values |
Answer should be recorded as a percent (%) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
percent | |||||||||
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Echo time (TE) | Numeric Values |
Answer should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.20 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C12540 | Imaging T2 measurement indicator | ImgT2MeasrInd | Indicator of whether T2 measurement was used | Indicator of whether T2 measurement was used | T2 measurement | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18718 | Imaging scanner strength value type other text | ImgScannerStrgthValTypOTH | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 2.10 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10584 | Imaging phase resolution percentage value | ImgPhasResltnPercentVal | The value in percent of the phase resolution used in imaging acquisition | The value in percent of the phase resolution used in imaging acquisition | Phase resolution | Numeric Values |
Must be answered with Partial Fourier, if Yes is answered for Fast Imaging |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
percent | |||||||||
C10682 | Imaging anatomic site | ImgAnatSite | Anatomic site of body part or anatomy scanned in the imaging study | Anatomic site of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:09.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C08240 | Imaging flip angle measurement | ImgFlipAngleMeasr | Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle | Measurement of the angle, in degrees over which the radio frequency changes proton spin angle | Flip angle | Numeric Values |
Answer should be recorded in degrees |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-18 15:21:17.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
degree | |||||||||
C12541 | Imaging contrast agent injection time | ImgContrastAgentInjctnTime | Time contrast medium was administered | Time contrast medium was administered | Time of injection | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18719 | Imaging slice orientation type other text | ImgSliceOrientTypOTH | The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition | The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-01 15:08:41.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10585 | Imaging phase partial Fourier indicator | ImgPhasPartialFourierInd | Indicator of whether phase partial Fourier was used | Indicator of whether phase partial Fourier was used | Partial Fourier | Yes;No | Yes;No | Alphanumeric |
Must be answered with Phase Resolution, if Yes is answered for Fast Imaging |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10685 | Imaging slice orientation type | ImgSliceOrientTyp | Type of slice orientation used in imaging acquisition | Type of slice orientation used in imaging acquisition | Slice Orientation | Axial;Coronal;Sagittal;Oblique | Axial;Coronal;Sagittal;Oblique | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:40.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Field of view | Numeric Values |
Answer should be recorded as a dimension (AAxAAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C17798 | Imaging contrast agent name | ImgContrastAgentName | Name of imaging contrast agent used | Name of imaging contrast agent used | If yes, name of the contrast | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
||||||||||
C10586 | Imaging bandwidth value | ImgBandwidthVal | Value, in Hertz per pixel, of bandwidth used in imaging acquisition | Value, in Hertz per pixel, of bandwidth used in imaging acquisitio | Band width | Numeric Values |
Answer should be recorded in Hx/Pixel |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C10837 | Imaging gap between slices measurement | ImgGapBetwnSlicesMeasr | Measurement of the gap between slices used in imaging acquisition | Measurement of the gap between slices used in imaging acquisition | Gap between slices | Numeric Values |
Answer should be recorded in millimeters squared (mm) or % (for 2D acquisition) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter |