CDE Detailed Report
Subdomain Name: Muscle Strength Testing
CRF: Hand Held Dynamometry
Displaying 1 - 9 of 9
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C10872 | Dynamometry hand held no result reason | DynmtryHandHldNoResltRsn | Reason why there was no hand held dynamometry result for the muscle | Reason why there was no hand held dynamometry result for the muscl | Reason No Result | Unable to test;Not done | Unable to test;Not done | Alphanumeric |
Choose one. Answer for each muscle type and each trial |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C17790 | Dynamometry hand held time | DynmtryHandHldTime | Time the hand held dynamometry was performed | Time the hand held dynamometry was performe | Time Performed | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Free-Form Entry |
||||||||||
C02411 | Laterality type | LatTyp | Laterality type relative to the anatomic site of the body examined or affected | Laterality type relative to the anatomic site of the body examined or affected | Muscle | Left;Right | Left;Right | Alphanumeric |
Record the hand held dynamometry result for each muscle and side |
Shefner J, Cudkowicz ME, Maragakis N, Cedarbaum JM, Lee J, Jones D, Watson ML, Shaver K, Chen M, Saikali K, Mao J, Russell AK, Hansen L, Malik F, Wolff AA, for the NEALS/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in Amyotrophic Lateral Sclerosis. (submitted for publication) | Adult;Pediatric | Supplemental | 3.00 | 2013-08-28 16:08:00.453 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C10171 | Trial number | TrialNum | The number representing the sequence for any repeated measure test or assessment when it is performed multiple times | The number representing the sequence for any repeated measure test or assessment when it is performed multiple times | Trial | Trial 1;Trial 2 | Trial 1;Trial 2 | Alphanumeric |
It is recommended that two hand held dynamometry trials be performed for each muscle |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. Shefner J, Cudkowicz ME, Maragakis N, Cedarbaum JM, Lee J, Jones D, Watson ML, Shaver K, Chen M, Saikali K, Mao J, Russell AK, Hansen L, Malik F, Wolff AA, for the NEALS/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in Amyotrophic Lateral Sclerosis. (submitted for publication) http://www.meddean.luc.edu/lumen/MedEd/medicine/pulmonar/fellow/pftm_f.htm | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C10864 | Dynamometry hand held muscle test performed indicator | DynmtryHandHldMuscTesPerfInd | Indicator of whether the hand held dynamometry testing was done | Indicator of whether the hand held dynamometry testing was don | Was the muscle testing done? | Yes;No | Yes;No | Alphanumeric |
Choose one |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C10865 | Dynamometry hand held muscle test performed date | DynmtryHandHldMuscTesPerfDate | Date (and time, if applicable and known) the hand held dynamometry was performed on the participant/subject | Date (and time, if applicable and known) the hand held dynamometry was performed on the participant/subjec | Date Performed | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Free-Form Entry |
||||||||||
C10867 | Dynamometry hand held muscle test performed anatomic site | DynmtrHandHldMusTesPerfAntSite | The type of muscle tested using hand held dynamometry | The type of muscle tested using hand held dynamometr | Muscle | Shoulder Flexion;Elbow Flexion;Elbow Extension;Wrist Extension;Hip Flexion;Knee Extension;Ankle Dorsiflexion;Knee Flexion;First Dorsal Interosseous;Other, specify | Shoulder Flexion (SF);Elbow Flexion (EF);Elbow Extension (EE);Wrist Extension (WE);Hip Flexion (HF);Knee Extension (KE);Ankle Dorsiflexion (AD);Knee Flexion (KF);First Dorsal Interosseous (FDI);Other, specify | Alphanumeric |
Record the hand held dynamometry result for each muscle and side |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C10869 | Dynamometry hand held muscle test result | DynmtryHandHldMuscTesReslt | The results of the trial performed by the participant/subject on the hand held dynamometer | The results of the trial performed by the participant/subject on the hand held dynamomete | Result | Numeric Values |
Answer should be recorded for each muscle type in pounds. |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Free-Form Entry |
pounds | |||||||||
C10871 | Dynamometry hand held muscle test able to break technique indicator | DynmtryHandHldMuscTBrkTechInd | Indicator of whether the examiner overpowered the maximal effort by the participant/subject, thereby producing a measurement of eccentric muscle strength | Indicator of whether the examiner overpowered the maximal effort by the participant/subject, thereby producing a measurement of eccentric muscle strengt | Break technique-Able to Break? | Yes;No | Yes;No | Alphanumeric |
Choose one. Answer for each muscle type and each trial. |
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Hand Held Dynamometry | Muscle Strength Testing | Outcomes and End Points |
Single Pre-Defined Value Selected |