CDE Detailed Report
Subdomain Name: Pulmonary Function Testing/Respiratory Status
CRF: Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry
Displaying 1 - 26 of 26
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C11003 | Cardiovascular myocardial oxygen consumption value | CardiovascMyocardOxyConsVal | Value, in mL/100 g/min, calculated for myocardial oxygen consumption (Mo2) | Value, in mL/100 g/min, calculated for myocardial oxygen consumption (Mo2 | Myocardial Oxygen Consumption (Mo2) | Numeric Values |
This is a derived/calculated value. |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
milliliter per 100 gram per minute | |||||||||
C11014 | Vascular partial pressure carbon dioxide transcutaneous increase greater than 15 mmHg indicator | VascPPCO2TransIncGrTh15mmHgInd | Indicator as to whether not the transcutaneous partial pressure carbon dioxide (pCO2) increased >15 mmHg over the 4-hour period monitored, as part of gas exchange | Indicator as to whether not the transcutaneous partial pressure carbon dioxide (pCO2) increased >15 mmHg over the 4-hour period monitored, as part of gas exchang | Is there an increase > 15 mmHg transcutaneous pCO2 | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Choose one |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C11004 | Cardiovascular myocardial oxygen consumption calculation type | CardiovascMyocardO2ConsCalcTyp | Type of calculation method used to obtain myocardial oxygen consumption (Mo2) | Type of calculation method used to obtain myocardial oxygen consumption (Mo2 | Mo2 calculation method | Intramyocardial wall tension, contractility, and heart rate;Estimated by heart rate and systolic blood pressure | Intramyocardial wall tension, contractility, and heart rate;Estimated by heart rate and systolic blood pressure | Alphanumeric |
Choose one |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C11015 | Polysomnography nocturnal oximetry start date and time | PolysomNoctOximtryStrtDateTime | Date and time of the start of nocturnal oximetry | Date and time of the start of nocturnal oximetr | Start date and time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
||||||||||
C11005 | Vascular partial pressure carbon dioxide mean value | VascPPCO2MeanVal | Value, as a percent, of the mean partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, as a percent, of the mean partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Mean pCO2 | Numeric Values |
Results should be recorded as a percent (%). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
percent | |||||||||
C11016 | Polysomnography nocturnal oximetry end date and time | PolysomNoctOximtryEndDateTime | Date and time of the end of nocturnal oximetry | Date and time of the end of nocturnal oximetr | End date and time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
||||||||||
C11006 | Vascular partial pressure carbon dioxide maximum value | VascPPCO2MaxVal | Value, as mmHg, of the maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, as mmHg, of the maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Maximum pCO2 | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C11017 | Polysomnography nocturnal oximetry recording device duration | PolysomNoctOximtryRecordDvcDur | Duration of nocturnal oximetry recording | Duration of nocturnal oximetry recordin | Recording time | Numeric Values |
Record response in hours and minutes. |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
minute | |||||||||
C01521 | Heart rate | HeartRate | The participant's pulse or number of contractions (heart beats) per minute | The participant's pulse or number of contractions (heart beats) per minute | Heart Rate | Numeric Values |
This value should be taken from the Vital Signs CRF to prevent capturing duplicate data in different places. Results should be recoreded in beats per minute (bpm). |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-03-11 10:48:30.0 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
0 | 300 | beats per minute | 2767073 | ||||||
C11007 | Vascular partial pressure carbon dioxide four hour period minimum value | VascPPCO2FourHrPdMinVal | Value, as mmHg, of the 4-hour minimum partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, as mmHg, of the 4-hour minimum partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Range of pCO2 over a 4 hour period, Minimum value | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C11018 | Polysomnography nocturnal oximetry net time duration | PolysomNoctOximtryNetTimeDur | Duration of net nocturnal oximetry recording | Duration of net nocturnal oximetry recordin | Net time | Numeric Values |
Record response in hours and minutes. |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
minute | |||||||||
C01554 | Oxygen saturation measurement | O2SatMeasr | Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetry | Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetr | Baseline SpO2 | Numeric Values |
Record the value as a percent (%). |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
0 | 100 | percent | |||||||
C11008 | Vascular partial pressure carbon dioxide four hour period maximum value | VascPPCO2FourHrPdMaxVal | Value, as mmHg, of the 4-hour maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, as mmHg, of the 4-hour maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Range of pCO2 over a 4 hour period, Maximum value | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C11020 | Polysomnography oxygen saturation mean value | PolysomOxygSaturatMeanVal | Value, as a percent, of mean O2 saturation (SPO2) in nocturnal oximetry, as part of nocturnal oximetry | Value, as a percent, of mean O2 saturation (SPO2) in nocturnal oximetry, as part of nocturnal oximetr | Mean SpO2 | Numeric Values |
Record the value as a percent (%). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
percent | |||||||||
C01565 | Blood pressure systolic measurement | BldPressrSystMeasr | Measurement of pressure of the participant's blood against the artery walls during systole (the contraction phase) in millimeters of mercury (mmHg) | Measurement of pressure of the participant's blood against the artery walls during systole (the contraction phase) in millimeters of mercury (mmHg) | Systolic blood pressure | Numeric Values |
Record the systolic blood pressure of the participant/ subject. The standard unit for measuring blood pressure is mmHg, which is approximately equivalent to Torr. This value should be taken from the Vital Signs CRF to prevent capturing duplicate data in different places. |
No references available | Adult;Pediatric | Core | 3.10 | 2024-03-11 10:40:09.0 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
0 | 300 | millimeter of mercury | 2004289 | C25298 | |||||
C11009 | Vascular partial pressure carbon dioxide increase greater than 15 mmHg indicator | VascPPCO2IncrGrThan15mmHgInd | Indicator as to whether or not the partial pressure carbon dioxide (pCO2) increased >15mmHg over the 4-hour period monitored, as part of Gas Exchange | Indicator as to whether or not the partial pressure carbon dioxide (pCO2) increased >15mmHg over the 4-hour period monitored, as part of Gas Exchang | Is there an increase > 15 mmHg in pCO2 | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Choose one |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Single Pre-Defined Value Selected |
||||||||
C11021 | Polysomnography nocturnal oximetry desaturation total count | PolysomNoctOximtryDesatTtlCt | Count total of desaturations in nocturnal oximetry, as part of nocturnal oximetry | Count total of desaturations in nocturnal oximetry, as part of nocturnal oximetr | Total number of desaturations | Numeric Values |
Record the integer value. |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
||||||||||
C10997 | Cardiovascular left ventricular systolic pressure measurement | CardiovascLVSystolicPressMeasr | Value, in mmHg, of the left ventricular systolic pressure, as part of myocardial oxygen consumption | Value, in mmHg, of the left ventricular systolic pressure, as part of myocardial oxygen consumption | Left ventricular (LV) systolic pressure | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C11010 | Vascular partial pressure carbon dioxide mean transcutaneous value | VascPPCO2MeanTrancutVal | Value, as a percent, of the mean transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, as a percent, of the mean transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Mean transcutaneous pCO2 | Numeric Values |
Results should be recorded as a percent (%). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
percent | |||||||||
C11022 | Polysomnography oxygen saturation below 89 percent time duration | PolysomOxySatBelow98PctTimeDur | Duration total of O2 saturation (SPO2) below 89% in nocturnal oximetry, as part of nocturnal oximetry | Duration total of O2 saturation (SPO2) below 89% in nocturnal oximetry, as part of nocturnal oximetr | Total time SpO2 below 89% | Numeric Values |
Record response in hours and minutes. |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
minute | |||||||||
C10998 | Cardiovascular end diastolic volume measurement | CardiovascEndDiastolVolMeasr | Value, in mL, of the end-diastolic volume, as part of myocardial oxygen consumption | Value, in mL, of the end-diastolic volume, as part of myocardial oxygen consumptio | End-diastolic volume | Numeric Values |
Results should be recorded in milliliters (mL). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
milliliter | |||||||||
C11011 | Vascular partial pressure carbon dioxide maximum transcutaneous value | VascPPCO2MaxTranscutVal | Value, in mmHg, of the maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, in mmHg, of the maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Maximum transcutaneous pCO2 | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C10999 | Cardiovascular left ventricular wall thickness measurement | CardiovascLVWallThickMeasr | Value, in cm, of the left ventricular wall thickness, as part of myocardial oxygen consumption | Value, in cm, of the left ventricular wall thickness, as part of myocardial oxygen consumptio | Left ventricular (LV) wall thickness | Numeric Values |
Results should be recorded in centimeters (cm). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
centimeter | |||||||||
C11012 | Vascular partial pressure carbon dioxide four hour period minimum transcutaneous value | VascPPCO2FourHrPdMinTransVal | Value, in mmHg, of the 4 hour minimum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange | Value, in mmHg, of the 4 hour minimum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang | Range of transcutaneous pCO2 over a 4 hour period, Minimum value | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury | |||||||||
C11000 | Cardiovascular contractility measurement | CardiovascContractMeasr | Value, in mmHg/mL, of cardiac contractility, as part of myocardial oxygen consumption | Value, in mmHg/mL, of cardiac contractility, as part of myocardial oxygen consumptio | Contractility | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg/mL). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury per milliliter | |||||||||
C11013 | Vascular partial pressure carbon dioxide four hour period maximum transcutaneous value | VascPPCO2FourHrPdMaxTransVal | Value, in mmHg, of the 4 hour maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of gas exchange | Value, in mmHg, of the 4 hour maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of gas exchang | Range of transcutaneous pCO2 over a 4 hour period, Maximum value | Numeric Values |
Results should be recorded in millimeters of mercury (mmHg). |
No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry | Pulmonary Function Testing/Respiratory Status | Outcomes and End Points |
Free-Form Entry |
millimeter of mercury |