CDE Detailed Report

Disease: Amyotrophic Lateral Sclerosis
Subdomain Name: Pulmonary Function Testing/Respiratory Status
CRF: Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry

Displaying 1 - 26 of 26
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C11004 Cardiovascular myocardial oxygen consumption calculation type CardiovascMyocardO2ConsCalcTyp Type of calculation method used to obtain myocardial oxygen consumption (Mo2) Type of calculation method used to obtain myocardial oxygen consumption (Mo2 Mo2 calculation method Intramyocardial wall tension, contractility, and heart rate;Estimated by heart rate and systolic blood pressure Intramyocardial wall tension, contractility, and heart rate;Estimated by heart rate and systolic blood pressure Alphanumeric

Choose one

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Single Pre-Defined Value Selected

C11015 Polysomnography nocturnal oximetry start date and time PolysomNoctOximtryStrtDateTime Date and time of the start of nocturnal oximetry Date and time of the start of nocturnal oximetr Start date and time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

C11005 Vascular partial pressure carbon dioxide mean value VascPPCO2MeanVal Value, as a percent, of the mean partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, as a percent, of the mean partial pressure carbon dioxide (pCO2), as part of Gas Exchang Mean pCO2 Numeric Values

Results should be recorded as a percent (%).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

percent
C11016 Polysomnography nocturnal oximetry end date and time PolysomNoctOximtryEndDateTime Date and time of the end of nocturnal oximetry Date and time of the end of nocturnal oximetr End date and time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

C11006 Vascular partial pressure carbon dioxide maximum value VascPPCO2MaxVal Value, as mmHg, of the maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, as mmHg, of the maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchang Maximum pCO2 Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11017 Polysomnography nocturnal oximetry recording device duration PolysomNoctOximtryRecordDvcDur Duration of nocturnal oximetry recording Duration of nocturnal oximetry recordin Recording time Numeric Values

Record response in hours and minutes.

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

minute
C01521 Heart rate HeartRate The participant's pulse or number of contractions (heart beats) per minute The participant's pulse or number of contractions (heart beats) per minute Heart Rate Numeric Values

This value should be taken from the Vital Signs CRF to prevent capturing duplicate data in different places. Results should be recoreded in beats per minute (bpm).

No references available Adult;Pediatric Supplemental 3.10 2024-03-11 10:48:30.0 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

0 300 beats per minute 2767073
C11007 Vascular partial pressure carbon dioxide four hour period minimum value VascPPCO2FourHrPdMinVal Value, as mmHg, of the 4-hour minimum partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, as mmHg, of the 4-hour minimum partial pressure carbon dioxide (pCO2), as part of Gas Exchang Range of pCO2 over a 4 hour period, Minimum value Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11018 Polysomnography nocturnal oximetry net time duration PolysomNoctOximtryNetTimeDur Duration of net nocturnal oximetry recording Duration of net nocturnal oximetry recordin Net time Numeric Values

Record response in hours and minutes.

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

minute
C01554 Oxygen saturation measurement O2SatMeasr Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetry Value, as a percent, of baseline O2 saturation (SPO2) in nocturnal oximetry, as part of Nocturnal Oximetr Baseline SpO2 Numeric Values

Record the value as a percent (%).

No references available Adult;Pediatric Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

0 100 percent
C11008 Vascular partial pressure carbon dioxide four hour period maximum value VascPPCO2FourHrPdMaxVal Value, as mmHg, of the 4-hour maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, as mmHg, of the 4-hour maximum partial pressure carbon dioxide (pCO2), as part of Gas Exchang Range of pCO2 over a 4 hour period, Maximum value Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11020 Polysomnography oxygen saturation mean value PolysomOxygSaturatMeanVal Value, as a percent, of mean O2 saturation (SPO2) in nocturnal oximetry, as part of nocturnal oximetry Value, as a percent, of mean O2 saturation (SPO2) in nocturnal oximetry, as part of nocturnal oximetr Mean SpO2 Numeric Values

Record the value as a percent (%).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

percent
C01565 Blood pressure systolic measurement BldPressrSystMeasr Measurement of pressure of the participant's blood against the artery walls during systole (the contraction phase) in millimeters of mercury (mmHg) Measurement of pressure of the participant's blood against the artery walls during systole (the contraction phase) in millimeters of mercury (mmHg) Systolic blood pressure Numeric Values

Record the systolic blood pressure of the participant/ subject. The standard unit for measuring blood pressure is mmHg, which is approximately equivalent to Torr. This value should be taken from the Vital Signs CRF to prevent capturing duplicate data in different places.

No references available Adult;Pediatric Core 3.10 2024-03-11 10:40:09.0 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

0 300 millimeter of mercury 2004289 C25298
C11009 Vascular partial pressure carbon dioxide increase greater than 15 mmHg indicator VascPPCO2IncrGrThan15mmHgInd Indicator as to whether or not the partial pressure carbon dioxide (pCO2) increased >15mmHg over the 4-hour period monitored, as part of Gas Exchange Indicator as to whether or not the partial pressure carbon dioxide (pCO2) increased >15mmHg over the 4-hour period monitored, as part of Gas Exchang Is there an increase > 15 mmHg in pCO2 Yes;No;Unknown Yes;No;Unknown Alphanumeric

Choose one

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Single Pre-Defined Value Selected

C11021 Polysomnography nocturnal oximetry desaturation total count PolysomNoctOximtryDesatTtlCt Count total of desaturations in nocturnal oximetry, as part of nocturnal oximetry Count total of desaturations in nocturnal oximetry, as part of nocturnal oximetr Total number of desaturations Numeric Values

Record the integer value.

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

C10997 Cardiovascular left ventricular systolic pressure measurement CardiovascLVSystolicPressMeasr Value, in mmHg, of the left ventricular systolic pressure, as part of myocardial oxygen consumption Value, in mmHg, of the left ventricular systolic pressure, as part of myocardial oxygen consumption Left ventricular (LV) systolic pressure Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11010 Vascular partial pressure carbon dioxide mean transcutaneous value VascPPCO2MeanTrancutVal Value, as a percent, of the mean transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, as a percent, of the mean transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang Mean transcutaneous pCO2 Numeric Values

Results should be recorded as a percent (%).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

percent
C11022 Polysomnography oxygen saturation below 89 percent time duration PolysomOxySatBelow98PctTimeDur Duration total of O2 saturation (SPO2) below 89% in nocturnal oximetry, as part of nocturnal oximetry Duration total of O2 saturation (SPO2) below 89% in nocturnal oximetry, as part of nocturnal oximetr Total time SpO2 below 89% Numeric Values

Record response in hours and minutes.

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

minute
C10998 Cardiovascular end diastolic volume measurement CardiovascEndDiastolVolMeasr Value, in mL, of the end-diastolic volume, as part of myocardial oxygen consumption Value, in mL, of the end-diastolic volume, as part of myocardial oxygen consumptio End-diastolic volume Numeric Values

Results should be recorded in milliliters (mL).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

milliliter
C11011 Vascular partial pressure carbon dioxide maximum transcutaneous value VascPPCO2MaxTranscutVal Value, in mmHg, of the maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, in mmHg, of the maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang Maximum transcutaneous pCO2 Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C10999 Cardiovascular left ventricular wall thickness measurement CardiovascLVWallThickMeasr Value, in cm, of the left ventricular wall thickness, as part of myocardial oxygen consumption Value, in cm, of the left ventricular wall thickness, as part of myocardial oxygen consumptio Left ventricular (LV) wall thickness Numeric Values

Results should be recorded in centimeters (cm).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

centimeter
C11012 Vascular partial pressure carbon dioxide four hour period minimum transcutaneous value VascPPCO2FourHrPdMinTransVal Value, in mmHg, of the 4 hour minimum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchange Value, in mmHg, of the 4 hour minimum transcutaneous partial pressure carbon dioxide (pCO2), as part of Gas Exchang Range of transcutaneous pCO2 over a 4 hour period, Minimum value Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11000 Cardiovascular contractility measurement CardiovascContractMeasr Value, in mmHg/mL, of cardiac contractility, as part of myocardial oxygen consumption Value, in mmHg/mL, of cardiac contractility, as part of myocardial oxygen consumptio Contractility Numeric Values

Results should be recorded in millimeters of mercury (mmHg/mL).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury per milliliter
C11013 Vascular partial pressure carbon dioxide four hour period maximum transcutaneous value VascPPCO2FourHrPdMaxTransVal Value, in mmHg, of the 4 hour maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of gas exchange Value, in mmHg, of the 4 hour maximum transcutaneous partial pressure carbon dioxide (pCO2), as part of gas exchang Range of transcutaneous pCO2 over a 4 hour period, Maximum value Numeric Values

Results should be recorded in millimeters of mercury (mmHg).

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

millimeter of mercury
C11003 Cardiovascular myocardial oxygen consumption value CardiovascMyocardOxyConsVal Value, in mL/100 g/min, calculated for myocardial oxygen consumption (Mo2) Value, in mL/100 g/min, calculated for myocardial oxygen consumption (Mo2 Myocardial Oxygen Consumption (Mo2) Numeric Values

This is a derived/calculated value.

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Free-Form Entry

milliliter per 100 gram per minute
C11014 Vascular partial pressure carbon dioxide transcutaneous increase greater than 15 mmHg indicator VascPPCO2TransIncGrTh15mmHgInd Indicator as to whether not the transcutaneous partial pressure carbon dioxide (pCO2) increased >15 mmHg over the 4-hour period monitored, as part of gas exchange Indicator as to whether not the transcutaneous partial pressure carbon dioxide (pCO2) increased >15 mmHg over the 4-hour period monitored, as part of gas exchang Is there an increase > 15 mmHg transcutaneous pCO2 Yes;No;Unknown Yes;No;Unknown Alphanumeric

Choose one

No references available Adult Exploratory 3.00 2013-07-22 16:57:17.79 Myocardial Oxygen Consumption, Gas Exchange and Nocturnal Oximetry Pulmonary Function Testing/Respiratory Status Outcomes and End Points

Single Pre-Defined Value Selected

CSV