CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Spectroscopy
Displaying 1 - 50 of 50
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C18714 | Imaging radio frequency coil channel count other text | ImgRFCoilChannelCtOTH | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Other, specify | Alphanumeric |
Record the number of coils for the applicable receiver coils. |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-06-29 16:40:00.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10577 | Imaging signal averages number | ImgSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition | Number of signal acquisitions averaged in imaging acquisition | Number of averages | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10959 | Spectroscopy spectral bandwidth value | SpectroSpectralBandwidthVal | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions | Spectral bandwidth | Numeric Values |
Answer should be recorded in Hertz per pixel (Hz/pixel) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C02498 | Imaging scanner software version number text | ImgScannerSftwrVrsnNumTxt | Free-text field specifying the version number of the imaging scanner software | Free-text field specifying the version number of the imaging scanner software | Version number | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C17860 | Spectroscopy PRESS asymmetry first echo duration | SpectPRESSAssym1stEchoDur | The duration in milliseconds for the first echo time (TE) in an asymmetrically divided PRESS (double spin-echo) sequence | Duration in milliseconds of first echo time | TE1 | Numeric Values | No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C18715 | Imaging radio frequency coil other text | ImgRFCoilOTH | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | Other, specify | Alphanumeric |
Check all that apply |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10682 | Imaging anatomic site | ImgAnatSite | Anatomic site of body part or anatomy scanned in the imaging study | Anatomic site of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Brain;Cervical spine;Thoracic spine;Lumbar spine;Calf;Thigh;Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:09.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C10960 | Spectroscopy PRESS symmetry type | SpectPRESSSymTyp | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided | For PRESS, is it symmetric or asymmetric | Symmetric;Asymmetric | Symmetric (TE = TE1 + TE2, TE1 = TE2);Asymmetric (TE1 =/= TE2) | Alphanumeric |
Include reference to define symmetric and asymmetric, as follows: Is it symmetric (TE = TE1 + TE2; TE1 = TE2) or asymmetric (TE1 not equal to TE2) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C02499 | Imaging pulse sequence type | ImgPulseSeqTyp | Type of imaging pulse sequence used | Type of imaging pulse sequence used | Type of imaging sequence used; whether it was single voxel (SVS), spectroscopic imaging (SI)-2D, spectroscopic imaging (SI)-3D, PRESS (Point Resolved Spectroscopy), STEAM (stimulated echo acquisition mode), or spin-echo. | T1;T2;FLAIR;DWI;GRE;SWI;DTI;MRSI;PWI;Gradient-echo;Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Post-contrast FLAIR;Post-contrast T1-weighted;COW MRA;TOF Neck MRA;CE MRA;Other, specify;FLASH;MPRAGE;SPGR;SPACE/VISTA;TSE/FSE;Dual echo PD/T2W SE;PD SE;T2W SE;T1W SE;T1W 3D gradient-echo;T1-weighted spin echo with contrast;T1-weighted spin echo without contrast;PD/T2W FSE;DIR;PSIR;fMRI;PRESS;Spectroscopic imaging 2D;Spectroscopic imaging 3D;Spin echo;STEAM;Single voxel spectroscopy (SVS);Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Multivoxel spectroscopy;Unlocalized spectroscopy;ISIS;DWI/ADC;rFOV;EPI | T1;T2;FLAIR;DWI;GRE;SWI;DTI;MRSI;PWI;Gradient-echo;Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Post-contrast FLAIR;Post-contrast T1-weighted;COW MRA;TOF Neck MRA;CE MRA;Other, specify;FLASH;MPRAGE;SPGR;SPACE/VISTA;TSE/FSE;Dual echo PD/T2W SE;PD SE;T2W SE;T1W SE;T1W 3D gradient-echo;T1-weighted spin echo with contrast;T1-weighted spin echo without contrast;PD/T2W FSE;DIR;PSIR;fMRI;PRESS;Spectroscopic imaging 2D;Spectroscopic imaging 3D;Spin echo;STEAM;Single voxel spectroscopy (SVS);Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Multivoxel spectroscopy;Unlocalized spectroscopy;ISIS;DWI/ADC;Reduced field of view (rFOV);Echo Planar Imaging (EPI) | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:35.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C17861 | Spectroscopy PRESS asymmetry second echo duration | SpectPRESSAssym2ndEchoDur | The duration in milliseconds for the second echo time (TE) in an asymmetrically divided PRESS (double spin-echo) sequence | Duration in milliseconds of second echo time | TE2 | Numeric Values | No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | ||||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Exploratory | 2.00 | 2022-06-28 13:09:35.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10838 | Imaging voxel size axis 1 measurement | ImgVoxelSizeAxis1Measr | Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest | Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest | Voxel size | Numeric Values |
To be answered for each sequence used. Answer should be recorded as a dimension (AAxAAxAA) and in millimeters (mm) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C10963 | Imaging B0-susceptibility distortion correction indicator | ImgB0SuscDistortCorrInd | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction | Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio | B0-shift correction | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C17862 | Spectroscopy water signal removal filter text | SpecWaterSignalRemFiltText | Text to describe the water signal removal filter used if the residual water signal was removed | Text to describe the water signal removal filter used if the residual water signal was remove | Water signal removal filter used | Alphanumeric | No references available | Adult | Exploratory | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C18718 | Imaging scanner strength value type other text | ImgScannerStrgthValTypOTH | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 2.10 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10938 | Imaging STEAM mixing duration | ImgSTEAMMixDur | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported | For STEAM, TM | Numeric Values |
Answer should be recorded in milliseconds (ms) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C10964 | Imaging eddy current induced spectral distortion correction indicator | ImgEddyCurIndSpDCoInd | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation | Eddy-current-induced spectral distortion correction | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Reptition time (TR) | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C17870 | Water reference data acquisition data acquisition time | WatRefDataAcqAcqTime | The acquisition time of the imaging. Water reference data acquisition section | The acquisition time of the imaging. Water reference data acquisition sectio | Acquisition time | Numeric Values | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
minute | ||||||||||
C18814 | Spectroscopy water suppression other text | SpectroWaterSupressMethodOTH | The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported | The free-text field related to 'Spectroscopy water suppression type' specifying other text. Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10942 | Imaging voxel anatomic site | ImgVoxelAntmicSite | The anatomic site in which the voxel is located (e.g., brain left frontal white matter) | The anatomic site in which the voxel is located (e.g., brain left frontal white matter | Anatomical location of voxel | Alphanumeric |
Only answered if SVS is checked as spectroscopy sequence parameter |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C10965 | Spectroscopy post process residual water signal remove indicator | SpectroscopyPostPrResidWRemInd | Indicator whether residual water signal was removed in post processing | Indicator whether residual water signal was removed in post processing | Residual water signal removed | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
If YES, record the name of the filter used to remove the water signal |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | Echo Time (TE) | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.20 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C17871 | Water reference data acquisition signal averages number | WatRefDataAcqSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition. Water reference data acquisition section | Number of signal acquisitions averaged in imaging acquisition. Water reference data acquisition sectio | Number of averages | Numeric Values | No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C18815 | Spectroscopy spectral fit software used other text | SpecSpectralFitSoftwrUseOTH | The free-text field related to 'Spectroscopy spectral fit software used type' specifying other text. Type of the spectral fit software used | The free-text field related to 'Spectroscopy spectral fit software used type' specifying other text. Type of the spectral fit software use | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10945 | Imaging voxel volume measurement | ImgVoxelVolMeasr | Volume of the voxel calculated by multiplying the three size measurements | Volume of the voxel calculated by multiplying the three size measurements | Voxel volume | Numeric Values |
Answer should be recorded in millimeters cubed (mm3) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
cubic millimeter | |||||||||
C10967 | Spectroscopy metabolite concentration unit type | SpecMetabolConcUntTyp | Type of the reported metabolite quantitation values in absolute unit (in mM or millimoles/liter) or in institutional unit (that is, not measuring T1 and T2 values of the metabolites, thereby not accounting for the signal loss due to TR and TE values u | Type of the reported metabolite quantitation values in absolute unit (in mM or millimoles/liter) or in institutional unit (that is, not measuring T1 and T2 values of the metabolites, thereby not accounting for the signal loss due to TR and TE values | Metabolite concentration reported in | Absolute value;Institutional unit;Ratio | Absolute value;Institutional unit;Ratio | Alphanumeric |
No instructions available |
No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | FOV | Numeric Values |
Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C18610 | Imaging in plane resolution axis 2 measurement | ImgInPlaneRsltnAxis2Measr | Axis 2 of in-plane spatial resolution used in imaging acquisition | Axis 2 of in-plane spatial resolution used in imaging acquisition | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||||
C10946 | Imaging spectroscopic chemical shift imaging slice coverage anatomical site | ImgSpectCSISlCovgAntmicSite | The anatomic site in which a chemical shift imaging (CSI) slice or slab is located and its extent of spatial coverage | The anatomic site in which a chemical shift imaging (CSI) slice or slab is located and its extent of spatial coverag | Anatomical coverage of CSI-slice or slab | Alphanumeric |
Only answered if SI is checked as spectroscopy sequence parameter |
No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C10968 | Spectroscopy CSF partial volume indicator | SpecCSFPartialVolInd | Indicator of whether partial volume occupied by cerebrospinal fluid (CSF) in voxels of interest is accounted for as a part of metabolite quantitation process | Indicator of whether partial volume occupied by cerebrospinal fluid (CSF) in voxels of interest is accounted for as a part of metabolite quantitation proces | Quantitation takes into account CSF partial volume? | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
No instructions available |
No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08242 | Imaging acquisition duration | ImgAcquisitionDur | Duration of the imaging scan in minutes | Duration of the imaging scan in minutes | Acquisition time | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
minute | |||||||||
C18611 | Imaging field of view axis 2 measurement | ImgFieldViewAxis2Measr | Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||||
C10948 | Imaging field of view axis 3 measurement | ImgFieldViewAxis3Measr | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Axis 3 of the image that is visible through the camera at a particular position in orientation and space in millimeters | z-direction (3D) | Numeric Values |
Answer should be recorded in millimeters (mm) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C10969 | Spectroscopy spectral fit software used type | SpecSpectralFitSoftwrUseTyp | Type of the spectral fit software used | Type of the spectral fit software use | Spectral fit software used | LCM;jMRUI;Other, specify | LCM;jMRUI;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08244 | Imaging slice thickness value | ImgSliceThicknessVal | Value of the thickness of the slice measured in millimeters (mm) | Value of the thickness of the slice measured in millimeters (mm) | Slice/slab thickness | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 99 | millimeter | |||||||
C18612 | Imaging in plane resolution axis 3 measurement | ImgInPlaneRsltnAxis3Measr | Axis 3 of in-plane spatial resolution used in imaging acquisition | Axis 3 of in-plane spatial resolution used in imaging acquisition | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||||
C10952 | Spectroscopy water suppression type | SpectroWaterSupressMethodTyp | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Indicator of water suppression method used, if any, for the spectroscopy scan being reported | Water suppression scheme | CHESS;Other, specify | CHESS;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17849 | Radio frequency receiver spine array channel count | RFRecvrSpineArrayChannelCt | Count of radio frequency (RF) receiver spine array channels | Count of radio frequency (RF) receiver spine array channel | Spine Array | Numeric Values | No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10567 | Imaging radio frequency coil type | ImgRFCoilTyp | Type of radio frequency (RF) coil(s) used for the body part scanned | Type of radio frequency (RF) coil(s) used for the body part scanned | RF receiver coil(s) and number of channels | Head coil;Neck coil;Spine array;Body coil (transmit);Double-cone;Circular;Figure 8;Other, specify | Head coil;Neck coil;Spine array;Body coil (transmit);Double-cone;Circular;Figure 8;Other, specify | Alphanumeric |
Check all that apply |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:34.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C18689 | Imaging anatomic site other text | ImgAnatSiteOTH | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | The free-text field related to 'Imaging anatomic site', specifying other text. Anatomic site of body part or anatomy scanned in the imaging study | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 1.10 | 2024-02-29 15:53:09.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10953 | Spectroscopy water signal suppression bandwidth value | SpectroWaterSupressBandwdthVal | Value, in Hz, of bandwidth of water suppression, if any, for the spectroscopy scan being reported | Value, in Hz, of bandwidth of water suppression, if any, for the spectroscopy scan being reported | Water signal suppression bandwidth | Numeric Values |
Answer should be recorded in Hertz (Hz) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz | |||||||||
C02495 | Imaging scanner strength value type | ImgScannerStrgthValTyp | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Magnetic Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify | 1.5T;3.0T;4.0T;7.0T;Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:31.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17858 | Imaging voxel size axis 2 measurement | ImgVoxelSizeAxis2Measr | Measurement, in millimeters, of the axis 2 dimension of the voxel within the anatomy of interest | Measurement, in millimeters, of the axis 2 dimension of the voxel within the anatomy of interest | Voxel size | Numeric Values | No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | ||||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Record the number of coils for the applicable receiver coils. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18708 | Imaging pulse sequence type other text | ImgPulseSeqTypOTH | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-01 14:55:04.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10958 | Spectroscopy spectral points count | SpectroSpectralPointCt | Count of the spectroscopic sequence parameter of spectral points used in the scan being reported | Count of the spectroscopic sequence parameter of spectral points used in the scan being reported | Spectral points | Numeric Values |
(data size) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
point | |||||||||
C02496 | Imaging scanner manufacturer name | ImgScannerManufName | Name of manufacturer of imaging scanner | Name of manufacturer of imaging scanner | Name of the scanner manufacturer | Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify | Agfa;Carestream;GE;Hitachi;Hologic;Konica Minolta;Philips;Siemens;Toshiba;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Exploratory | 4.00 | 2024-03-18 15:21:17.0 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17859 | Imaging voxel size axis 3 measurement | ImgVoxelSizeAxis3Measr | Measurement, in millimeters, of the axis 3 dimension of the voxel within the anatomy of interest | Measurement, in millimeters, of the axis 3 dimension of the voxel within the anatomy of interest | Voxel size | Numeric Values | No references available | Adult | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Magnetic Resonance Spectroscopy | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter |