CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 61 of 61
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C17925 | Imaging contrast agent dose | ImgContrastAgentDose | Dosage of the contrast agent used | Dosage of the contrast agent used | Dosage | Numeric Values | No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:47:39.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C10592 | Imaging flow compensation indicator | ImgFlowCompnsatnInd | Indicator of whether flow compensation was used in imaging acquisition | Indicator of whether flow compensation was used in imaging acquisition | Flow compensation | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18715 | Imaging radio frequency coil other text | ImgRFCoilOTH | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | Other, specify | Alphanumeric |
Check all that apply. |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name | Alphanumeric |
Record the scanner software name |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10964 | Imaging eddy current induced spectral distortion correction indicator | ImgEddyCurIndSpDCoInd | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) | Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation | DWI co-registered to b=0 image and corrected for subject motion and eddy current induced distortion (affine transformation) | Yes;No;Unknown | Yes;No;Unknown | Alphanumeric |
Affine transformation |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10577 | Imaging signal averages number | ImgSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition | Number of signal acquisitions averaged in imaging acquisition | Number of signal averages | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C18610 | Imaging in plane resolution axis 2 measurement | ImgInPlaneRsltnAxis2Measr | Axis 2 of in-plane spatial resolution used in imaging acquisition | Axis 2 of in-plane spatial resolution used in imaging acquisition | In-plane resolution | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2013-09-12 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C10593 | Imaging fat signal suppressed indicator | ImgFatSignalSuppressedInd | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Indicator as to whether or not fat signal was suppressed in imaging acquisition | Fat signal suppressed | Yes;No;Unknown;Not applicable | Yes;No;Unknown;Not applicable | Alphanumeric |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18716 | Imaging scanner manufacturer name other text | ImgScannerManufNameOTH | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner | Other, specify | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Exploratory | 2.00 | 2022-06-28 13:09:35.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Repetition time (RT) | Numeric Values |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||
C13905 | Imaging contrast agent method type | ImgContrastAgentMethodTyp | Indicates imaging contrast agent method of administration | Indicates imaging contrast agent method of administratio | If Yes, name of the contrast | Bolus;Infusion;Other, specify | Bolus;Infusion;Other, specify | Alphanumeric | No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |