CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10591 Imaging phase encode direction text ImgPhasEncdeDirctTxt Text description of the phase encode direction used in imaging technique acquisition Text description of the phase encode direction used in imaging technique acquisition Phase-encode direction Alphanumeric

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10963 Imaging B0-susceptibility distortion correction indicator ImgB0SuscDistortCorrInd Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correctio DWI co-registered to T2 image for B0-susceptibility distortion correction? Yes;No;Unknown Yes;No;Unknown Alphanumeric

Choose one

No references available Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used Sequence T1;T2;FLAIR;DWI;GRE;SWI;DTI;MRSI;PWI;Gradient-echo;Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Post-contrast FLAIR;Post-contrast T1-weighted;COW MRA;TOF Neck MRA;CE MRA;Other, specify;FLASH;MPRAGE;SPGR;SPACE/VISTA;TSE/FSE;Dual echo PD/T2W SE;PD SE;T2W SE;T1W SE;T1W 3D gradient-echo;T1-weighted spin echo with contrast;T1-weighted spin echo without contrast;PD/T2W FSE;DIR;PSIR;fMRI;PRESS;Spectroscopic imaging 2D;Spectroscopic imaging 3D;Spin echo;STEAM;Single voxel spectroscopy (SVS);Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Multivoxel spectroscopy;Unlocalized spectroscopy;ISIS;DWI/ADC;rFOV;EPI T1;T2;FLAIR;DWI;GRE;SWI;DTI;MRSI;PWI;Gradient-echo;Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Post-contrast FLAIR;Post-contrast T1-weighted;COW MRA;TOF Neck MRA;CE MRA;Other, specify;FLASH;MPRAGE;SPGR;SPACE/VISTA;TSE/FSE;Dual echo PD/T2W SE;PD SE;T2W SE;T1W SE;T1W 3D gradient-echo;T1-weighted spin echo with contrast;T1-weighted spin echo without contrast;PD/T2W FSE;DIR;PSIR;fMRI;PRESS;Spectroscopic imaging 2D;Spectroscopic imaging 3D;Spin echo;STEAM;Single voxel spectroscopy (SVS);Pulsed-ASL;Continuous-ASL;Pseudocontinuous-ASL;Multivoxel spectroscopy;Unlocalized spectroscopy;ISIS;DWI/ADC;Reduced field of view (rFOV);Echo Planar Imaging (EPI) Alphanumeric

DTI sequence parameters

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C17925 Imaging contrast agent dose ImgContrastAgentDose Dosage of the contrast agent used Dosage of the contrast agent used Dosage Numeric Values No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:39.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition In-plane resolution Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
C18715 Imaging radio frequency coil other text ImgRFCoilOTH The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned Other, specify Alphanumeric

Check all that apply.

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10592 Imaging flow compensation indicator ImgFlowCompnsatnInd Indicator of whether flow compensation was used in imaging acquisition Indicator of whether flow compensation was used in imaging acquisition Flow compensation Yes;No;Unknown;Not applicable Yes;No;Unknown;Not applicable Alphanumeric

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10964 Imaging eddy current induced spectral distortion correction indicator ImgEddyCurIndSpDCoInd Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation DWI co-registered to b=0 image and corrected for subject motion and eddy current induced distortion (affine transformation) Yes;No;Unknown Yes;No;Unknown Alphanumeric

Affine transformation

No references available Adult;Pediatric Exploratory 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name Alphanumeric

Record the scanner software name

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18610 Imaging in plane resolution axis 2 measurement ImgInPlaneRsltnAxis2Measr Axis 2 of in-plane spatial resolution used in imaging acquisition Axis 2 of in-plane spatial resolution used in imaging acquisition In-plane resolution Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 1.00 2013-09-12 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10577 Imaging signal averages number ImgSignalAvgNum Number of signal acquisitions averaged in imaging acquisition Number of signal acquisitions averaged in imaging acquisition Number of signal averages Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

CSV