CDE Detailed Report

Disease: system
Subdomain Name: Imaging Diagnostics
CRF: files

Displaying 51 - 56 of 56
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10570 Imaging contrast agent used indicator ImgContrastAgentUsedInd Indicator of whether an imaging contrast agent was used for the scan Indicator as to whether or not an imaging contrast agent was used for the scan Contrast used Yes;No Yes;No Alphanumeric

Choose one. If yes, record the name of the contrast agent and its dosage.

No references available Adult;Pediatric Supplemental 3.10 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10594 Imaging parallel acquisition used indicator ImgParallelAcquistionUsedInd Indicator of whether a parallel acquisition method is used in imaging acquisition Indicator of whether a parallel acquisition method is used in imaging acquisition Parallel acquisition used Yes;No Yes;No Alphanumeric

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters.

No references available Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08239 Imaging echo duration ImgEchoDur Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition Echo time (TE) Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.20 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C10933 Imaging lesion found type ImgLesnFoundTyp Type of lesions found in the imaging study Type of lesions found in the imaging study If yes, type of lesion(s) WM hyperintensity;Infarct;Spondylosis;Other, specify WM hyperintensity;Infarct;Spondylosis;Other, specify Alphanumeric

Choose all that apply. Only answered if "Lesions found?" was answered Yes

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:53.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18715 Imaging radio frequency coil other text ImgRFCoilOTH The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned Other, specify Alphanumeric

Check all that apply

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition In-plane resolution Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
CSV