CDE Detailed Report

Disease: Amyotrophic Lateral Sclerosis
Subdomain Name: Imaging Diagnostics
CRF: Magnetic Resonance Imaging (MRI)

Displaying 51 - 56 of 56
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C18718 Imaging scanner strength value type other text ImgScannerStrgthValTypOTH The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported Other, specify Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 2.10 2024-03-18 15:21:17.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10685 Imaging slice orientation type ImgSliceOrientTyp Type of slice orientation used in imaging acquisition Type of slice orientation used in imaging acquisition Slice orientation Axial;Coronal;Sagittal;Oblique;Other, specify Axial;Coronal;Sagittal;Oblique;Other, specify Alphanumeric

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:40.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the slice measured in millimeters (mm) Slice thickness Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C17811 Imaging phase partial Fourier value ImgPhasPartialFourierVal Value of the phase partial Fourier ratio, if used in imaging acquisition Value of the phase partial Fourier ratio, if used in imaging acquisition Partial Fourier - if Yes, specify Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank.

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10586 Imaging bandwidth value ImgBandwidthVal Value, in Hertz per pixel, of bandwidth used in imaging acquisition Value, in Hertz per pixel, of bandwidth used in imaging acquisitio Band width Numeric Values

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Exploratory 3.00 2013-07-25 08:54:08.2 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz per pixel
C18719 Imaging slice orientation type other text ImgSliceOrientTypOTH The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition Other, specify Alphanumeric

If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 15:08:41.0 Magnetic Resonance Imaging (MRI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

CSV