CDE Detailed Report

Disease: Parkinson's Disease
Sub-Domain: Imaging Diagnostics
CRF: PET-SPECT

Displaying 1 - 50 of 70
CDE ID CDE Name Variable Name Definition Short Description Additional Notes (Question Text) Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guideline) Sub Domain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C18038 Isotope other text IsotopeOthrTxt Specify in text the type of radioactive isotope used for the imaging scan if it is not listed above Specify in text the type of radioactive isotope used for the imaging scan if it is not listed above Isotope Other, Specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C18722 Imaging volume of interest anatomic location other text ImgVOIAntmicLocOTH The free-text field related to 'Imaging volume of interest anatomic location type' specifying other text. Type of anatomic location used for volume of interest (VOI) for the imaging data analysis The free-text field related to 'Imaging volume of interest anatomic location type' specifying other text. Type of anatomic location used for volume of interest (VOI) for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Camera Software Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08255 Imaging visual analysis blinded indicator ImgVisAnlysisBlindInd Indicator of whether the visual analysis was performed blinded to clinical data Indicator of whether the visual analysis was performed blinded to clinical data Was where the visual analysis performed blinded to clinical data? Yes;No;Unknown Yes;No;Unknown Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18049 Imaging outcome other name ImgOutcmeOthrName Name other than listed above of the primary imaging outcome Name other than listed above of the primary imaging outcome Imaging Outcome: Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08268 Imaging volume of interest placement method type ImgVOIPlacementMthdTyp Type of method used for volume of interest (VOI) placement for the imaging data analysis Type of method used for volume of interest (VOI) placement for the imaging data analysis Method for VOI placement Automated;Subjective Placement;Other, specify Automated;Subjective Placement;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18706 Imaging post reconstruction filter other text ImgPstReconstrctFltrOTH The free-text field related to 'Imaging post reconstruction filter type' specifying other text. Type of post reconstruction filter used to smooth image data The free-text field related to 'Imaging post reconstruction filter type' specifying other text. Type of post reconstruction filter used to smooth image data Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18039 Scanner manufacturer other text ScannerManufactOthrTxt Specify in text the type and manufacturer name of the scanner if it is not listed above Specify in text the type and manufacturer name of the scanner if it is not listed above Other camera (Include Type of scanner and Manufacturer), specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C18723 Imaging volume of interest placement method other text ImgVOIPlacementMthdOTH The free-text field related to 'Imaging volume of interest placement method type' specifying other text. Type of method used for volume of interest (VOI) placement for the imaging data analysis The free-text field related to 'Imaging volume of interest placement method type' specifying other text. Type of method used for volume of interest (VOI) placement for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08242 Imaging acquisition duration ImgAcquisitionDur Duration of the imaging scan in minutes The duration of the imaging acquisition, in minutes Duration of Scan (minutes) Numeric Values

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C08258 Imaging radioligand type ImgRadiolgndTyp Isotope-labeled bioactive compound (generic or common name) used in the imaging scan Isotope-labeled bioactive compound (generic or common name) used in the imaging scan Radioligand DaTSCAN;Altropane;?-CIT;FDG;Florbetapir;Florbetaben;Florbetamol;PIB;DOPA;MIBG;Fluoro-metatyrosine (FMT);2-deoxy-glucose (either C14 or H3);AMT;FCWAY;H2O15;Other, specify;FMZ;ECD;HMPAO DaTSCAN;Altropane;?-CIT;FDG;Florbetapir;Florbetaben;Florbetamol;PIB;DOPA;MIBG;Fluoro-metatyrosine (FMT);2-deoxy-glucose (either C14 or H3);AMT;FCWAY;H2O15;Other, specify;FMZ;ECD;HMPAO Alphanumeric

choose only one

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18053 Fdopa binding ratio other text FdopaBindRatOthrTxt Specify in text the type of F-dopa binding ratio other than listed above Specify in text the type of F-dopa binding ratio other than listed above Fdopa: Oher, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08269 Imaging volume of interest anatomic location type ImgVOIAntmicLocTyp Type of anatomic location used for volume of interest (VOI) for the imaging data analysis Type of anatomic location used for volume of interest (VOI) for the imaging data analysis VOI Locations Striatum;Cortex;Other, specify Striatum;Cortex;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18707 Imaging pre-scan procedure other text ImgPrescnProcdrOTH The free-text field related to 'Imaging pre-scan procedure type' specifying other text. Type(s) of pre-scan procedures administered to the participant/subject The free-text field related to 'Imaging pre-scan procedure type' specifying other text. Type(s) of pre-scan procedures administered to the participant/subject Other, specify Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18040 Radioligand dose other unit of measure RadiolgndDoseOthrUoM Other unit of measure for the dose of injected radioligand for the imaging scan Other unit of measure for the dose of injected radioligand for the imaging scan Unit of Measure, Other Specify Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08243 Imaging matrix size value ImgMatrixSizeVal Value representing the imaging matrix size in millimeters Value representing the imaging matrix size in millimeters Image Matrix Size 64 x 64;128 x 128;512 x 512;Other, specify;256 x 256 64 x 64;128 x 128;512 x 512;Other, specify;256 x 256 Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

millimeter
C08259 Imaging radioligand specific activity value ImgRadiolgndActVal Value of the specific activity of the Radioligand in Bq/Kg Value of the specific activity of the Radioligand in Bq/Kg Specific activity of radioligand in Bq/kg Numeric Values

if the activity is unknown, enter or check "Unknown"

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 10000 Becquerel per kilogram
C18054 Imaging amyloid standard uptake value anatomic site other name ImgAmyloidSUVAntmSiteOthrName Name(s) of anatomic site(s) other than listed above where the amyloid imaging standard uptake value (SUV) was measured Name(s) of anatomic site(s) other than listed above where the amyloid imaging standard uptake value (SUV) was measured Amyloid Imaging Standard Uptake Value (SUV): Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08270 Imaging reference region text ImgRefRegnTxt Text that describes the reference region used for the imaging scan and analysis Text that describes the reference region used for the imaging scan and analysis Reference Region Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18709 Imaging quantitative outcome other text ImgQuantOutcmeOTH The free-text field related to 'Imaging quantitative outcome type' specifying other text. Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis The free-text field related to 'Imaging quantitative outcome type' specifying other text. Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18041 Imaging matrix size other scale ImgMatrxSizeOthrScale Scale other than listed above to indicate the resolution of image matrix size in field of view Scale other than listed above to indicate the resolution of image matrix size in field of view Image Matrix Size, Other Specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08244 Imaging slice thickness value ImgSliceThicknessVal Value of the thickness of the slice measured in millimeters (mm) Value of the thickness of the optical slice measured in millimeters (mm) Slice Thickness (mm) Numeric Values

This value should be captured in millimeters (mm)

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 millimeter
C08260 Imaging isotope type ImgIsotopeTyp Type of radioactive isotope used for the imaging scan Type of radioactive isotope used for the imaging scan Isotope 123-I;18-F;11-C;99 Tcm;Other, specify 123-I;18-F;11-C;99 Tcm;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18613 Imaging medication pre-treatment withheld name ImgMedctnPrtrtmntWithhldName Name of the pre-treatment withheld agent or drug Medication pre-treatment withheld name Alphanumeric

Record the verbatim name (generic or trade name) of the medication the participant/subject reports taking. Add date stamp for when assessed. For TBI studies recommend collection is at least on date of TBI.

RXNorm (http://www.nlm.nih.gov/research/umls/rxnorm/); NCI Common Data Element Browser Public ID = 3162728 Adult;Pediatric Supplemental 1.00 2013-09-25 00:00:00.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

3162728
C08271 Imaging quantitative outcome type ImgQuantOutcmeTyp Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis Primary quantitative outcome to describe tracer distribution and uptake for the imaging data analysis Quantitative Imaging Outcome DAT Scan;Altropane;?-CIT;Fluoro-metatyrosine (FMT);FDopa;Amyloid Imaging Standardized Uptake Value (SUV);Scan aborted;Other, specify DAT Scan;Altropane;?-CIT;Fluoro-metatyrosine (FMT);FDopa;Amyloid Imaging Standardized Uptake Value (SUV);Scan aborted;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18710 Imaging radioligand dose other text ImgRadiolgndDoseOTH The free-text field related to 'Imaging radioligand dose unit of measure' specifying other text. Unit of measure for the dose of injected radioligand for the imaging scan The free-text field related to 'Imaging radioligand dose unit of measure' specifying other text. Unit of measure for the dose of injected radioligand for the imaging scan Other, specify Alphanumeric

Choose one

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18042 Post-injection management other text ImgPstInjctMngmntOthrTxt Specify in text the special management post injection prior to image scan if it is not listed above Specify in text the special management post injection prior to image scan if it is not listed above Post Injection Management prior to scan: Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08246 Imaging pre-scan procedure type ImgPrescnProcdrTyp Type(s) of pre-scan procedures administered to the participant/subject Type(s) of pre-scan action(s) administered to the participant/subject Pre-Scan action(s) Lugols;Perchlorate;Withhold medications;Limit sensory stimulation;Other, specify Lugols;Perchlorate;Withhold medications;Limit sensory stimulation;Other, specify Alphanumeric

Choose all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08261 Imaging radioligand dose value ImgRadiolgndDosVal Dose of injected radioligand for the imaging scan Dose of injected radioligand for the imaging scan Dose Numeric Values

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-08-28 16:08:00.453 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18688 Imaging amyloid standard uptake value anatomic other text ImgAmyloidSUVAntmicSiteOTH The free-text field related to 'Imaging amyloid standard uptake value anatomic site' specifying other text. Name of anatomic site where the amyloid imaging standard uptake value (SUV) was measured The free-text field related to 'Imaging amyloid standard uptake value anatomic site' specifying other text. Name of anatomic site where the amyloid imaging standard uptake value (SUV) was measured Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08272 Imaging F-dopa binding ratio type ImgFdopaBindRatTyp Type of F-dopa binding ratio with respect to the rest of the brain Type of F-dopa binding ratio with respect to the rest of the brain Fdopa Striatal (Regional);Putamen;Caudate;Other, specify Striatal (Regional);Putamen;Caudate;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18711 Imaging radioligand other text ImgRadiolgndOTH The free-text field related to 'Imaging radioligand type' specifying other text. Isotope-labeled bioactive compound (generic or common name) used in the imaging scan The free-text field related to 'Imaging radioligand type' specifying other text. Isotope-labeled bioactive compound (generic or common name) used in the imaging scan Other, specify Alphanumeric

choose only one

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18043 Raw data reconstruction other text RawDataReconstrctOthrTxt Specify in text method other than listed above used for reconstruction of raw data from the imaging scan Specify in text method other than listed above used for reconstruction of raw data from the imaging scan Reconstruction of raw data: Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08247 Imaging medication pre-treatment status ImgMedctnPretrtmntStatus Status of the medication(s) taken by the participant/subject pre-treatment for the imaging scan Status of the medication(s) taken by the participant/subject pre-treatment for the imaging scan Parkinson's Disease Medication(s) Status – Pre-treatment All medications withheld;Specific medication(s) withheld;No medication(s) withheld All medications withheld;Specific medication(s) withheld;No medication(s) withheld Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08262 Imaging radioligand dose unit of measure ImgRadiolgndDoseUoM Unit of measure for the dose of injected radioligand for the imaging scan Unit of measure for the dose of injected radioligand for the imaging scan Unit of Measure mCi;Mbq;Other, specify mCi;Mbq;Other, specify Alphanumeric

Choose one

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18692 Imaging attenuation correction method other text ImgAttenuCorrectMethdOTH The free-text field related to 'Imaging attenuation correction method type' specifying other text. Method to correct for different tissues density when analyzing the image The free-text field related to 'Imaging attenuation correction method type' specifying other text. Method to correct for different tissues density when analyzing the image Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08273 Imaging F-dopa binding ratio value ImgFdopaBindRatVal Value of the F-dopa binding ratio with respect to the rest of the brain Value of the F-dopa binding ratio with respect to the rest of the brain Fdopa binding ratio numeric Numeric Values

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18712 Imaging raw data reconstruction method other text ImgRawDataReconstructMthdOTH The free-text field related to 'Imaging raw data reconstruction method type' specifying other text. The type of method used for reconstruction of raw data from the imaging scan The free-text field related to 'Imaging raw data reconstruction method type' specifying other text. The type of method used for reconstruction of raw data from the imaging scan Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C18044 Attenuation correction other text AttenuatCorrctOthrTxt Specify in text the method other than listed above used to correct for different tissues density when analyzing the image Specify in text the method other than listed above used to correct for different tissues density when analyzing the image Attenuation Correction: Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08248 Imaging medication pre-treatment withheld duration ImgMedctnPretrtmntWithldDur Duration of time medication(s) were withheld from the participant/subject pre-treatment for the imaging scan Duration of time medication(s) were withheld from the participant/subject pre-treatment for the imaging scan If a medication was withheld, how long was it withheld? Numeric Values

Answered only if 'All medications withheld' was checked Only answer if 'All medications withheld' or 'Specific medication(s) withheld' are answered for 'PD medications pre-treatment'

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C08263 Imaging radioligand injection to acquisition elapsed time ImgRadiolgndInj2AcqDur Duration in minutes from radioligand injection to imaging acquisition Duration in minutes from radioligand injection to imaging acquisition Time from Injection to Scan (minutes) Numeric Values

This value should be captured in minutes

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

minute
C18698 Imaging F-dopa binding ratio other text ImgFdopaBindRatOTH The free-text field related to 'Imaging F-dopa binding ratio type' specifying other text. Type of F-dopa binding ratio with respect to the rest of the brain The free-text field related to 'Imaging F-dopa binding ratio type' specifying other text. Type of F-dopa binding ratio with respect to the rest of the brain Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08274 Imaging amyloid standard uptake value anatomic site name ImgAmyloidSUVAntmicSiteName Name of anatomic site where the amyloid imaging standard uptake value (SUV) was measured Name of anatomic site where the amyloid imaging standard uptake value (SUV) was measured Amyloid Imaging Standard Uptake Value (SUV) Neocortex;Posterior cingual/precuneus;Frontal;Parietal;Lateral;Temporal;Mesiotemporal;Anterior cingulate;Striatum;Cerebellar gray;Whole cerebellum;Other, specify Neocortex;Posterior cingual/precuneus;Frontal;Parietal;Lateral;Temporal;Mesiotemporal;Anterior cingulate;Striatum;Cerebellar gray;Whole cerebellum;Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18716 Imaging scanner manufacturer other text ImgScannerManufOTH The free-text field related to 'Imaging scanner manufacturer name' specifying other text. Name of manufacturer of imaging scanner The free-text field related to 'Imaging scanner manufacturer name' specifying other text. Name of manufacturer of imaging scanner Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C01541 Weight measurement WgtMeasr Measurement of participant's/subject's weight Measurement of participant's/subject's weight Current Body Weight Numeric Values

Record the weight of the participant/subject in kilograms (kg). To be collected at the visit, not self-reported.

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 500 kilogram 2179689
C18045 Post reconstruction filter other text PstReconstrctFltrOthrTxt Specify in text the type of post reconstruction filter other than listed above used to smooth image data Specify in text the type of post reconstruction filter other than listed above used to smooth image data Post Reconstruction Filter: Other, specify Alphanumeric No references available Adult Supplemental 3.00 2013-07-20 10:46:24.96 PET-SPECT Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C08249 Imaging medication pre-treatment withheld duration unit of measure ImgMedctnPrtrtmntWithhldDurUOM Unit of measure used to specify the length of time medication(s) were withheld from the participant/subject pre-treatment for the imaging scan Unit of measure (UOM) used to specify the length of time medication(s) were withheld from the participant/subject pre-treatment for the imaging scan Days, Hours , Minutes Days;Hours;minutes Days;Hours;minutes Alphanumeric

Choose one

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08264 Imaging raw data reconstruction method type ImgRawDataReconstructMthdTyp The type of method used for reconstruction of raw data from the imaging scan The type of method used for reconstruction of raw data from the imaging scan Reconstruction of raw data Iterative;Filtered back projection;Other, specify Iterative;Filtered back projection;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18699 Imaging isotope other text ImgIsotopeOTH The free-text field related to 'Imaging isotope type' specifying other text. Type of radioactive isotope used for the imaging scan The free-text field related to 'Imaging isotope type' specifying other text. Type of radioactive isotope used for the imaging scan Other, specify Alphanumeric

No instructions available

No references available Adult Supplemental 1.00 2014-05-27 13:34:46.0 PET-SPECT Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C08275 Imaging amyloid standard uptake value anatomic site value ImgAmyloidSUVAntmicSiteVal Amyloid imaging standard uptake value (SUV) for the anatomic site Amyloid imaging standard uptake value (SUV) for the anatomic site Amyloid Imaging Standard Uptake Value (SUV) Numeric Values

No instructions available

No references available Adult Supplemental 3.00 2013-07-22 09:34:41.527 PET-SPECT Imaging Diagnostics Assessments and Examinations

Free-Form Entry

CSV