CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 74 of 74
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C14016 | High intensity transient signal hits start time | HighIntensTransSigHitStartTime | Indicates high intensity transient signal hits start time | Indicates high intensity transient signal hits start time | Start Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C13954 | Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up date and time | COGIFFollowupDateTime | The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-up | The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-u | Date, Time | Date or Date & Time |
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.). |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C14034 | Vasomotor response (VMR) vessel anatomic site | VMRVesselAntmicSite | Indicates vasomotor response (VMR) vessel type | Indicates vasomotor response (VMR) vessel type | Vessel | MCA;Other, specify | Middle cerebral artery;Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13751 | Imaging acquisition reason | ImgAcquisitionRsn | Describes why the imaging study was performed | Describes why the imaging study was performed | Scan purpose | Initial;Monitoring | Initial;Monitoring | Alphanumeric |
Select all that apply |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C14006 | Imaging stenosis percentage value | ImgStenosisPercentageVal | Indicates stenosis percentage value | Indicates stenosis percentage value | Percent Stenosis | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 99 | percent | |||||||
C18903 | Vasomotor response (VMR) vessel anatomic other text | VMRVesselAntmicOTH | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type | Other, specify | Alphanumeric |
Use the specific codelist that corresponds to the type of imaging done |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C13944 | Imaging color flow indicator | ImgColorFlowInd | Indicates color flow | Indicates color flow | Color flow | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14020 | Sickle cell disease vessel anatomic site | SickleCellDisVesselAntmicSite | Indicates sickle cell vessel | Indicates sickle cell vessel | Vessel(s) | MCA;Other, specify | Middle cerebral artery;Other, specify | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13955 | Imaging transcranial color-coded sonography symptomatic indicator | ImgTCCSSymptomaticInd | Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) | Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) | Symptomatic | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14035 | VMR response result | VMRResponseReslt | Indicates vasomotor response (VMR) response result | Indicates vasomotor response (VMR) response result | VMR | Abnormal;Normal | Abnormal;Normal | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C58867 | Imaging chronic stroke type | ImgChronStrkStudTyp | Indicates chronic stroke type | Indicates chronic stroke type | Chronic Stroke | Hemisphere;Eye;Vetebrobasilar | Hemisphere;Eye;Vetebrobasilar | Alphanumeric |
Indicate the type of chronic stroke |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-18 11:12:20.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13899 | Imaging probe type text | ImgProbeTypTxt | The text describing the type of imaging probe | Describes imaging probe type | Type | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C14007 | Imaging Transcranial Doppler (TCD) findings result type | ImgTCDFindResltTyp | Indicates Transcranial Doppler (TCD) findings | Indicates Transcranial Doppler (TCD) findings | Findings | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) | Alphanumeric |
Select all that apply. Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C13945 | Imaging spectrum depth measurement | ImgSpectrumDepthMeasr | Indicates spectrum depth measurement (mm) | Indicates spectrum depth measurement (mm) | Depth | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millimeter | |||||||
C14021 | Sickle cell disease blood flow velocity measurement | SickleCellVelBldFlowMeasr | The velocity measurement blood flow relative to sickle cell disease | The velocity measurement blood flow relative to sickle cell diseas | Velocity | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | centimeter per second | |||||||
C13956 | High intensity transient signal hits duration | HighIntensTransSignalHitsDur | Indicates high intensity transient signal hits duration time (msec) | Indicates high intensity transient signal hits duration time (msec) | Duration time | Numeric Values |
Indicate duration time in units of msec |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
0 | 999 | millisecond | |||||||
C14036 | Breath-holding index result | BreathHoldingIndexReslt | Indicates Breath-holding index (BHI) result | Indicates breath-holding index (BHI) result | Breath-holding index (BHI) | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||
C58868 | Imaging transient ischemic attack type | ImgTIATyp | Indicates type of transient ischemic attack | Indicates type of transient ischemic attack | TIA | Hemisphere;Eye;Vetebrobasilar | Hemisphere;Eye;Vetebrobasilar | Alphanumeric |
Indicate the type of TIA |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2020-05-18 11:20:04.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13900 | Imaging probe frequency | ImgProbeFreq | Indicates imaging probe frequency (Hz) | Indicates imaging probe frequency (Hz) | Frequency | Numeric Values |
Indicate frequency in units of Hz |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz | |||||||||
C14008 | Imaging window quality category | ImgWindowQualityCat | Indicates window quality category | Indicates window quality category | Insonation window | Temporal;Posterior;Orbital | Temporal;Posterior;Orbital | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13946 | Imaging spectrum angle correction indicator | ImgSpectrumAngleCorrectionInd | Indicates spectrum angle correction | Indicates spectrum angle correction | Angle correction | Yes;No | Yes;No | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C14023 | Sickle cell disease diagnosis result | SickleCellDiagnosReslt | Indicates sickle cell diagnosis result | Indicates sickle cell diagnosis result | Sickle Cell (indication for study) | Abnormal;Normal;Conditional | Abnormal;Normal;Conditional | Alphanumeric |
Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C13957 | High intensity transient signal hits intensity value | HighIntensTransSignalHitsVal | Indicates high intensity transient signal hits intensity value (dB) | Indicates high intensity transient signal hits intensity value (dB) | Intensity | Numeric Values |
Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response) |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-06-21 00:00:00.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
decibel | |||||||||
C14037 | Imaging power M mode left middle cerebral artery result type | ImgPowerMModeLeftMCAResTyp | Indicates power M mode for left middle cerebral artery (MCA) result | Indicates power M mode for left middle cerebral artery (MCA) result | Left MCA | Absent;High Resistance;Low Resistance | Absent;High Resistance;Low Resistance | Alphanumeric |
These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2021-11-19 15:28:20.0 | Vessel Imaging Transcranial | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |