CDE Detailed Report

Disease: system
Subdomain Name: Imaging Diagnostics
CRF: system

Displaying 51 - 74 of 74
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C13945 Imaging spectrum depth measurement ImgSpectrumDepthMeasr Indicates spectrum depth measurement (mm) Indicates spectrum depth measurement (mm) Depth Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 millimeter
C14036 Breath-holding index result BreathHoldingIndexReslt Indicates Breath-holding index (BHI) result Indicates breath-holding index (BHI) result Breath-holding index (BHI) Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C13956 High intensity transient signal hits duration HighIntensTransSignalHitsDur Indicates high intensity transient signal hits duration time (msec) Indicates high intensity transient signal hits duration time (msec) Duration time Numeric Values

Indicate duration time in units of msec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 millisecond
C14008 Imaging window quality category ImgWindowQualityCat Indicates window quality category Indicates window quality category Insonation window Temporal;Posterior;Orbital Temporal;Posterior;Orbital Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58868 Imaging transient ischemic attack type ImgTIATyp Indicates type of transient ischemic attack Indicates type of transient ischemic attack TIA Hemisphere;Eye;Vetebrobasilar Hemisphere;Eye;Vetebrobasilar Alphanumeric

Indicate the type of TIA

No references available Adult;Pediatric Supplemental 1.00 2020-05-18 11:20:04.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13900 Imaging probe frequency ImgProbeFreq Indicates imaging probe frequency (Hz) Indicates imaging probe frequency (Hz) Frequency Numeric Values

Indicate frequency in units of Hz

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C14023 Sickle cell disease diagnosis result SickleCellDiagnosReslt Indicates sickle cell diagnosis result Indicates sickle cell diagnosis result Sickle Cell (indication for study) Abnormal;Normal;Conditional Abnormal;Normal;Conditional Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13946 Imaging spectrum angle correction indicator ImgSpectrumAngleCorrectionInd Indicates spectrum angle correction Indicates spectrum angle correction Angle correction Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14037 Imaging power M mode left middle cerebral artery result type ImgPowerMModeLeftMCAResTyp Indicates power M mode for left middle cerebral artery (MCA) result Indicates power M mode for left middle cerebral artery (MCA) result Left MCA Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Supplemental 4.00 2021-11-19 15:28:20.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13957 High intensity transient signal hits intensity value HighIntensTransSignalHitsVal Indicates high intensity transient signal hits intensity value (dB) Indicates high intensity transient signal hits intensity value (dB) Intensity Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

decibel
C14009 Imaging window quality result ImgWindowQualityReslt Indicates window quality result for all categories Indicates window quality result for all categories Window quality Fair;Excellent;Poor Fair;Excellent;Poor Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; and Flow direction)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58905 Imaging transcranial ultrasound performed type ImgTranscrnUltrsndPerfmdTyp Indicates the ultrasound type Indicates the ultrasound type Ultrasound Type Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) Alphanumeric

Indicate ultrasound type

No references available Adult;Pediatric Supplemental 1.00 2020-05-19 14:23:40.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13901 Imaging patient type ImgPatientTyp Indicates imaging patient type Indicates imaging patient type Patient type Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14024 Vasospasm criterion value VasoCriterionVal Indicates vasospasm criterion value Indicates vasospasm criterion value Criterion Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13947 Imaging peak velocity measurement ImgPeakVelocityMeasr Indicates peak velocity measurement (cm/sec) Indicates peak velocity measurement (cm/sec) Peak velocity Numeric Values

Indicate peak velocity in units of cm/sec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 centimeter per second
C14038 Imaging power M mode right middle cerebral artery result type ImgPowerMModeRightMCAResTyp Indicates power M mode for right middle cerebral artery (MCA) result Indicates power M mode for right middle cerebral artery (MCA) result Right MCA Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Supplemental 4.00 2021-11-19 15:52:18.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13960 High intensity transient signal hits vessel anatomic site HighIntensTransSigHitAnatSite Indicates high intensity transient signal hits vessel category Indicates high intensity transient signal hits vessel category High intensity transient signal hits M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14010 Intracranial stenosis collateral vessel anatomic site IntracrnStnoColltVsslAntmicSit Indicates intracranial stenosis collateral vessel(s) Indicates intracranial stenosis collateral vessel(s) Vessel(s) ICA;Basilar;MCA;Other, specify;VA Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Vertebral artery Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58906 Vasospasm resistive index value VasospasmRestistIndexVal Indicates vasospasm resistive Index (RI) Indicates vasospasm resistive Index (RI) Resistive index Numeric Values

(RI) These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 1.00 2020-05-19 17:46:31.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13902 Imaging acute stroke study type ImgAcutStokStudTyp Indicates imaging acute stroke study type Indicates imaging acute stroke study type Indicate study type Initial;Follow-up 1;Follow-up 2 Initial;Follow-up 1;Follow-up 2 Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14025 Vasospasm Lindegaard ratio value VasoLinegaardRatioVal Indicates vasospasm lindegaard ratio result Indicates vasospasm Lindegaard ratio result Lindegaard ratio Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13948 Imaging mean blood velocity measurement ImgMeanBloodVelocityMeasr Indicates mean velocity measurement (cm/sec) of blood Indicates mean velocity measurement (cm/sec) of blood Mean velocity Numeric Values

Indicate mean velocity in units of cm/sec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 centimeter per second
C14051 High intensity transient signal hits end time HighIntensTransSigHitEndTime Indicates high intensity transient signal hits end time Indicates high intensity transient signal hits end time End Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13961 High intensity transient signal hits present indicator HighIntensTransSigHitPresInd Indicates presence of high intensity transient signals hits Indicates presence of high intensity transient signals hits High intensity transient signal hits Yes;No Yes;No Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

CSV