C58851
Physical activity increase intervention other text
The free-text field related to 'Physical activity increase intervention type' specifying other text. If the participant/subject received recommendations to increase physical activity, describes the type(s) of interventions received
Supplemental
Lifestyle Modification Therapies
False
Stroke
Stroke
C01713
Lab test result unit of measure UCUM code
Unified Code for Units of Measure (UCUM) unit code for the result of the lab test being performed on the specimen
Supplemental
Laboratory Tests
False
Stroke
Stroke
C19057
Diabetes mellitus complications other text
The free-text field related to 'Diabetes mellitus complications type' specifying other text. Type(s) of complications related to diabetes mellitus the participant/subject has experienced or is experiencing
Supplemental
Medical History
False
Stroke
Stroke
C14189
Neonatal encephalopathy level type
Level of neonatal encephalopathy according to the Sarnat Staging
Supplemental
Assessment of Transient Neurologic Deficits Resolved Prior to Presentation
False
Stroke
Stroke
C21939
Pediatric Quality of Life Inventory (PedsQL) - Problem low energy difficulty scale
Scale of problems with low energy, as part of the Pediatric Quality of Life Inventory (PedsQL)
Supplemental
Pediatric Quality of Life Inventory (PEDSQL)
True
Stroke
Stroke
C54276
Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) - Visuospatial constructional versus attention difference score
Difference score calculated as a subtraction of Attention index score from Visuospatial/Constructional index score, as part of the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS)
Supplemental
Repeatable Battery for Assessment of Neuropsychological Status (RBANS)
True
Stroke
Stroke
C12908
Echocardiogram intracardiac find type
Type of intracardiac findings observed by echocardiography
Supplemental
Echocardiogram II
False
Stroke
Stroke
C54082
Delis-Kaplan Executive Function System (DKEFS) Trail Making Test (TMT) - Part B total error count
The total number of errors made by the participant during their completion of Trail B, as part of the Delis-Kaplan Executive Function System (D-KEFS) Trail-Making Test (TMT)
Supplemental
Trail Making Test (TMT), Delis-Kaplan Executive Function System (D-KEFS)
False
Stroke
Stroke
C21922
Wechsler Adult Intelligence Scale III (WAIS III) - Digit span backward subtest trial score
Trial score, as part of Wechsler Adult Intelligence Scale III (WAIS III) Digit Span Backward subtest
Supplemental
Wechsler Adult Intelligence Scale - Fourth Edition (WAIS-IV)
True
Stroke
Stroke
C54738
Aneurysm thrombus indicator
Indicator for the presence of evidence of thrombus
Supplemental
Aneurysm Location and Dimensions
False
Stroke
Stroke
C20440
Beck Depression Inventory II (BDI-II) - Tiredness fatigue scale
Scale identifying level of tiredness or fatigue, as part of the Beck Depression Inventory II (BDI-II)
Supplemental
Beck Depression Inventory II (BDI-II)
True
Stroke
Stroke
C10744
Echocardiogram left ventricle fractional shortening measurement
Measurement of the difference between end-diastolic and end-systolic dimensions of the left ventricle divided by end-diastolic dimension assessed with echocardiography. FS or Fractional Shortening in percentage = EDD minus ESD divided by EDD times 100, where EDD = LV End Diastolic Dimension and ESD = LV End Systolic Dimension
Supplemental
Echocardiogram II
False
Stroke
Stroke
C20462
Brief Visuospatial Memory Test - Revised (BVMT-R) - Learning T-score
T-score for Learning portion of Brief Visuospatial Memory Test - Revised (BVMT-R)
Supplemental
Brief Visuospatial Memory Test Revised (BVMT-R)
True
Stroke
Stroke
C13146
Stroke Specific Quality of Life Scale (SS-QOL) - trouble speaking language scale
The scale for having trouble speaking based on Stroke Specific Quality of Life Scale (SS-QOL)
Supplemental
Stroke Specific Quality of Life Scale (SS-QOL)
True
Stroke
Stroke
C10740
Echocardiogram left ventricle ejection fraction measurement
Fraction of blood pumped out of the left ventricles with each heart beat measured with echocardiography
Supplemental
Echocardiogram
False
Stroke
Stroke
C54770
Imaging aneurysm wall shear stress mean measurement
Measurement of the mean wall shear stress of the aneurysm, as computed from imaging
Supplemental
Vessel Imaging Angiography
False
Stroke
Stroke
C06005
Data collected date and time
Date (and time, if applicable and known) the data were collected. This may be the date/time a particular examination or procedure was performed
Supplemental
Family History
False
Stroke
Stroke
C14055
Stroke Adjudication Worksheet - neuroimaging MRI stroke finding indicator
Whether the MRI was positive for this stroke event
Supplemental
Stroke Adjudication Form
False
Stroke
Stroke
C14263
Childhood AIS standardized classification and diagnostic evaluation (CASCADE) - primary chronic sub type
Childhood AIS standardized classification and diagnostic evaluation (CASCADE) primary classification: chronic - patients with an initial vascular diagnosis (at 0-1 month) for "Primary Classification: Acute" are given a follow-up diagnosis based on studies obtained at or after 3-6 months that will capture any progression, stability or regression of the arteriopathy
Supplemental
Stroke Types and Subtypes
False
Stroke
Stroke
C13851
Arteriovenous malformation anatomic site
Specifies Location of arteriovenous malformation
Supplemental
Parenchymal Imaging
False
Stroke
Stroke
C58861
Recreational prescription drug abuse discontinue intervention other text
The free-text field related to 'Recreational prescription drug abuse discontinue intervention type' specifying other text. If the participant/subject received counseling to discontinue recreational or prescription drug abuse, describes the type(s) of interventions received
Supplemental
Lifestyle Modification Therapies
False
Stroke
Stroke
C58757
Lab test unit type
Indicator of whether United States Customary Units (Standard) or International Standard of Units (SI) were used in the laboratory test results
Supplemental
Laboratory Tests
False
Stroke
Stroke
C13881
Digital Subtraction Angiography (DSA) injection site anatomic site
The site of injection for digital subtraction angiography (DSA), a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment
Supplemental
Vessel Imaging Angiography
False
Stroke
Stroke
C52600
Medical history transient ischemic attack range
The element related to the number of transient ischemic attacks (TIAs) the participant/subject has had
Supplemental
Medical History
False
Stroke
Stroke
C13831
Graeb intraventricular hemorrhage (IVH) scale - right lateral ventricle score
Indicates Graeb IVH Scale - Right lateral ventricle score
Supplemental
Stroke Types and Subtypes
False
Stroke
Stroke