CDE Catalog

***Please contact the NINDS CDE Team (NINDSCDE@emmes.com) if you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport-Related Concussion (SRC) or Traumatic Brain Injury (TBI) as the Disease, please select a Subdisease as well.

NeuroRehab Comprehensive includes all NeuroRehab CDE recommendations. NeuroRehab General includes all NeuroRehab CDE recommendations that are not disease specific. All other NeuroRehab Subdiseases include recommendations specific to existing NINDS CDE project disorders.

Choose your Time Frame for your SRC study (Acute (time of injury until 72 hours), Subacute (after 72 hours to 3 months), and Persistent/Chronic (3 months and greater post-concussion) or Comprehensive if your study falls across the study time frames.

Choose your type of TBI study (Acute Hospitalized, Concussion/Mild TBI, Moderate/Severe TBI: Rehabilitation, or Epidemiology) or Comprehensive if your study falls outside of the study types or incorporates aspects of more than one type of study.

Search Form

Displaying 201 - 225 of 675
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Subdisease Name
C10786 Electrophysiology motor unit number estimation nerve type

Type of nerve where an electrical signal is measured with the MUNE (motor unit number estimation) technique

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12743 Electrophysiology neuromuscular jitter mean consecutive difference average value

Value, in microseconds, for the average of mean consecutive differences (MCD) recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12702 Electrophysiology sensory nerve impulse direction type

The impulse direction put on the nerve during the sensory nerve conduction study

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C10777 Electrophysiology study type

Type of electrophysiology study conducted

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12755 Electrophysiology Valsalva ratio

The Valsalva ratio measured during autonomic function testing

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12712 Electrophysiology blink reflex test R1 latency value

Duration of R1 latency in the blink reflex test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12763 Electrophysiology tilt study heart rate change result

Heart rate changes experienced from a tilt test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12720 Electrophysiology repetitive nerve stimulation study preactivation area measurement

Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12771 Electrophysiology long exercise test post-exercise compound muscle action potential time

The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise for the long exercise test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12728 Needle electromyography electrode type

Type of electrode used for the needle electromyography

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12736 Needle electromyography motor unit action potential activation type

The activation of the motor unit action potential measure during needle electromyography

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12693 Electrophysiology H-reflex nerve segment name

The nerve segment used for the H-reflex test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12744 Electrophysiology neuromuscular jitter mean consecutive difference abnormal count

Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12703 Electrophysiology sensory nerve segment length measurement

The sensory nerve segment length measured during the sensory nerve conduction study

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C10778 Electrophysiology motor unit number estimation muscle studied name

Name of the muscle studied using the MUNE (motor unit number estimation) technique

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12704 Electrophysiology sensory nerve onset or peak latency value

The onset or peak latency measured during the sensory nerve conduction study

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12756 Electrophysiology blood pressure response Valsalva phase II early result

The blood pressure response to valsalva maneuver during Phase II early

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12713 Electrophysiology blink reflex test ipsilateral R2 latency value

Duration of ipsilateral R2 latency in the blink reflex test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12764 Electrophysiology tilt study blood pressure change result

Blood Pressure changes experienced from a tilt test

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12721 Electrophysiology repetitive nerve activation technique type

Indicator of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12772 Electrophysiology long exercise test post-exercise compound muscle action potential measurement

Compound muscle action potential (CMAP) measurement recorded post- long exercise

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12729 Needle electromyography spontaneous activity type

The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12737 Needle electromyography interference pattern analysis technique name

The interference pattern technique used for analysis measure during needle electromyography

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12696 Electrophysiology motor nerve segment name

The name of the segment used for the motor nerve conduction study

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
C12745 Electrophysiology neuromuscular jitter study blocking count

Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology Myotonic Muscular Dystrophy Myotonic Muscular Dystrophy
Displaying 201 - 225 of 675

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.