CDE Catalog

***Please contact the NINDS CDE Team (NINDSCDE@emmes.com) if you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport-Related Concussion (SRC) or Traumatic Brain Injury (TBI) as the Disease, please select a Subdisease as well.

NeuroRehab Comprehensive includes all NeuroRehab CDE recommendations. NeuroRehab General includes all NeuroRehab CDE recommendations that are not disease specific. All other NeuroRehab Subdiseases include recommendations specific to existing NINDS CDE project disorders.

Choose your Time Frame for your SRC study (Acute (time of injury until 72 hours), Subacute (after 72 hours to 3 months), and Persistent/Chronic (3 months and greater post-concussion) or Comprehensive if your study falls across the study time frames.

Choose your type of TBI study (Acute Hospitalized, Concussion/Mild TBI, Moderate/Severe TBI: Rehabilitation, or Epidemiology) or Comprehensive if your study falls outside of the study types or incorporates aspects of more than one type of study.

Search Form

Displaying 276 - 300 of 1067
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Subdisease Name
C12873 Echocardiogram tricuspid valve stenosis degree status

Status of the degree of tricuspid valve stenosis as assessed by echocardiography

Supplemental Echocardiogram Myasthenia Gravis Myasthenia Gravis (MG)
C00012 Education level USA type

Highest grade or level of school participant/subject has completed or the highest degree received

Core Social Status - MG Myasthenia Gravis Myasthenia Gravis (MG)
C00015 Education year count

Number of years of education completed (age 5 and beyond)

Supplemental-Highly Recommended General Core Myasthenia Gravis Myasthenia Gravis (MG)
C12239 Electron microscopy performed indicator

Indicator of whether electron microscopy was performed

Supplemental Muscle Biopsy and Autopsy Tissue Myasthenia Gravis Myasthenia Gravis (MG)
C12239 Electron microscopy performed indicator

Indicator of whether electron microscopy was performed

Supplemental Peripheral Nerves - Biopsies and Autopsies Myasthenia Gravis Myasthenia Gravis (MG)
C10780 Electrophysiology anatomic site

Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12710 Electrophysiology assessment date and time

Date the particular electrophysiology study was performed

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12740 Electrophysiology neuromuscular jitter activation technique type

The activation technique used for the neuromuscular jitter test

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12739 Electrophysiology neuromuscular jitter electrode type

The type of electrode used for the neuromuscular jitter test

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12744 Electrophysiology neuromuscular jitter mean consecutive difference abnormal count

Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12743 Electrophysiology neuromuscular jitter mean consecutive difference average value

Value, in microseconds, for the average of mean consecutive differences (MCD) recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12775 Electrophysiology neuromuscular jitter mean normal limit value

Value of the mean of the normal limits recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12776 Electrophysiology neuromuscular jitter pair or endplate normal limit value

Value of the pair/endplate normal limit recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12742 Electrophysiology neuromuscular jitter pair or endplate study count

Count of the pairs/endplates studied in the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12741 Electrophysiology neuromuscular jitter stimulation type

Indicator of the stimulation technique, if applicable, used for activation in the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12745 Electrophysiology neuromuscular jitter study blocking count

Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C17976 Electrophysiology neuromuscular jitter study date

Date of neuromuscular jitter studies done

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12723 Electrophysiology repetitive nerve activation duration

Duration, in sec, of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12721 Electrophysiology repetitive nerve activation technique type

Indicator of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12722 Electrophysiology repetitive nerve high frequency

Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12726 Electrophysiology repetitive nerve postactivation amplitude measurement

Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12727 Electrophysiology repetitive nerve postactivation area measurement

Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12724 Electrophysiology repetitive nerve postactivation elapsed time duration

Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12725 Electrophysiology repetitive nerve postactivation number

The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
C12719 Electrophysiology repetitive nerve stimulation study preactivation amplitude measurement

Measurement, in mV, of the amplitude of the preactivation being described for the repetitive nerve study being recorded

Supplemental Electrophysiology - MG Myasthenia Gravis Myasthenia Gravis (MG)
Displaying 276 - 300 of 1067

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.