CDE Catalog

***Please contact NINDS CDE team (NINDSCDE@emmes.com) in case you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport-Related Concussion (SRC) or Traumatic Brain Injury (TBI) as the Disease, please select a Subdisease as well.

NeuroRehab Comprehensive includes all NeuroRehab CDE recommendations. NeuroRehab General includes all NeuroRehab CDE recommendations that are not disease specific. All other NeuroRehab Subdiseases include recommendations specific to existing NINDS CDE project disorders.

Choose your Time Frame for your SRC study (Acute (time of injury until 72 hours), Subacute (after 72 hours to 3 months), and Persistent/Chronic (3 months and greater post-concussion) or Comprehensive if your study falls across the study time frames.

Choose your type of TBI study (Acute Hospitalized, Concussion/Mild TBI, Moderate/Severe TBI: Rehabilitation, or Epidemiology) or Comprehensive if your study falls outside of the study types or incorporates aspects of more than one type of study.

Search Form

Displaying 251 - 275 of 612
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Subdisease Name
C15405 Imaging brain volume fraction value

Ratio of whole brain parenchymal volume to total intracranial volume or other head-size normalization volume

Supplemental-Highly Recommended Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15460 Imaging spinal cord lesion location type

Specifies the location of lesions with respect to cord cross-sectional area involving spinal gray matter

Exploratory Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C18694 Imaging diffusion measurement other text

The free-text field related to 'Imaging diffusion measurement type' specifying other text. Type of diffusion tensor imaging (DTI) measurement

Supplemental Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15419 Imaging change in gray matter volume fraction value

Percent change in gray matter volume fraction as compared to a reference scan acquired at an earlier timepoint

Exploratory Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15434 Imaging white matter volume fraction value

Ratio of white matter volume to total intracranial volume or other head-size normalization volume

Exploratory Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15449 Imaging hippocampus volume measurement

Hippocampus volume measurement

Supplemental Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15356 Imaging new posterior fossa lesion count

Total number of new focal T2-hyperintense brain lesions that are in contact with the posterior fossa (brainstem or cerebellum)

Supplemental Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15386 Imaging Gadolinium-enhancing lesion technique reference name

Name of software package used, website, and/or a citation to a journal article referencing the particular technique used to find Gadolinium-enhancing lesions

Supplemental Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15406 Imaging change in brain volume fraction percentage value

Percent change in whole brain volume fraction as compared to a reference scan acquired at an earlier timepoint

Supplemental Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C15411 Imaging ventricular volume fraction value

Ratio of ventricular volume to total intracranial volume or other head-size normalization volume

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15433 Imaging brain volume fraction technique type

Image analysis method used to calculate whole brain volume fraction

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15458 Imaging spinal cord lesion anatomic site

Specifies the location of lesions in the spinal cord with respect to the different levels of vertebrae (cervical-C, thoracic-T, lumbar-L)

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C02499 Imaging pulse sequence type

Type of imaging pulse sequence used

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15351 Imaging regional T2 lesion count

Number of regional T2 lesions

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15381 Imaging Gadolinium-enhancing lesion total volume measurement

Total volume of all focal lesions that are gadolinium (Gd)-enhancing on T1-weighted brain images

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C17448 Imaging measurement region type

Region of imaging measurement

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C19003 Imaging brain volume fraction technique other text

The free-text field related to 'Imaging brain volume fraction technique type' specifying other text. Image analysis method used to calculate whole brain volume fraction

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15511 Imaging tissue integrity type performed indicator

Whether the imaging type was performed on specific brain tissue

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15415 Imaging gray matter volume measurement

Volume of the gray matter

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15434 Imaging white matter volume fraction value

Ratio of white matter volume to total intracranial volume or other head-size normalization volume

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15460 Imaging spinal cord lesion location type

Specifies the location of lesions with respect to cord cross-sectional area involving spinal gray matter

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C08244 Imaging slice thickness value

Value of the thickness of the slice measured in millimeters (mm)

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15357 Imaging periventricular lesion count

Total number of focal T2-hyperintense brain lesions that are in contact with the ventricular system

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15386 Imaging Gadolinium-enhancing lesion technique reference name

Name of software package used, website, and/or a citation to a journal article referencing the particular technique used to find Gadolinium-enhancing lesions

Supplemental Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C18589 Imaging spinal cord area value

Area of the spinal cord

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
Displaying 251 - 275 of 612

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.