CDE Catalog

***Please contact NINDS CDE team (NINDSCDE@emmes.com) in case you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport Related Concussion or Traumatic Brain Injury as the Disease, please select a Sub-Disease as well.

NeuroRehab Comprehensive includes all CDE recommendations.

NeuroRehab General includes all CDE recommendations that are not disease specific.

All other NeuroRehab Sub-Diseases include recommendations specific to existing NINDS CDE project disorders.

Search Form

Displaying 26 - 50 of 1733
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Sub Disease Name
C57040 Fatigue diary activity type

Type of activity entered in the Fatigue Diary

Exploratory Fatigue/Activity Record and Diary Multiple Sclerosis Multiple Sclerosis
C10854 Grip device width setting value

Value of the width setting on the grip device used to test the participant/subject's grip strength

Exploratory Grip Strength Fatigue Multiple Sclerosis Multiple Sclerosis
C16209 Imaging retinal nerve fiber layer thickness in nasal quadrant measurement

The retinal nerve fiber layer (RNFL) thickness of the nasal quadrant

Exploratory Imaging OCT Analysis - Spectralis Report Analysis Multiple Sclerosis Multiple Sclerosis
C15434 Imaging white matter volume fraction value

Ratio of white matter volume to total intracranial volume or other head-size normalization volume

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15460 Imaging spinal cord lesion location type

Specifies the location of lesions with respect to cord cross-sectional area involving spinal gray matter

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15335 Optical coherence tomography (OCT) total macula volume measurement

Total macula volume by optical coherence tomography (OCT).

Exploratory Imaging OCT Analysis - Stratus Retinal Thickness Report Multiple Sclerosis Multiple Sclerosis
C15490 Imaging regional brain volume technique type

Image analysis method used to calculate other regional volume or regional volume fractions

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15360 Imaging retinal nerve fiber layer thickness in superior quadrant measurement

The retinal nerve fiber layer (RNFL) thickness of the superior quadrant

Exploratory Imaging OCT Analysis - RNFL Thickness Analysis Multiple Sclerosis Multiple Sclerosis
C15318 Imaging follow-up scan indicator

Indicates if scan is a follow-up

Exploratory Imaging OCT Analysis - Spectralis Report Analysis Multiple Sclerosis Multiple Sclerosis
C11515 Bladder Control Scale (BLCS) - altered activities because bladder problems 4 week scale

The scale related to altered activities because of bladder problems 4 week scale as part of the Bladder Control Scale (BLCS)

Exploratory Bladder Control Scale (BLCS) Multiple Sclerosis Multiple Sclerosis
C15365 Imaging retinal nerve fiber layer thickness in superior quadrant abnormal status

Whether the average retinal nerve fiber layer (RNFL) thickness of the superior quadrant of the eye is thin compared to the rest of the population

Exploratory Imaging OCT Analysis - Spectralis Report Analysis Multiple Sclerosis Multiple Sclerosis
C15415 Imaging gray matter volume measurement

Volume of the gray matter

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C11523 Bowel Control Scale (BWCS) - sum score value

Sum of the score for questions in the Bowel Control Scale (BWCS).

Exploratory Bowel Control Scale (BWCS) Multiple Sclerosis Multiple Sclerosis
C15319 Optical coherence tomography contrast and visual acuity testing laterality type

The eye examined during high/low contrast and visual acuity testing by optical coherence tomography (OCT)

Exploratory Imaging OCT Analysis - Contrast and Visual Acuity Multiple Sclerosis Multiple Sclerosis
C06005 Data collected date and time

Date (and time, if applicable and known) the data were collected. This may be the date/time a particular examination or procedure was performed.

Exploratory Fatigue/Activity Record and Diary Multiple Sclerosis Multiple Sclerosis
C15339 Optical coherence tomography (OCT) macular cube total volume measurement

Total volume of the macular cube by optical coherence tomography (OCT).

Exploratory Imaging OCT Analysis -Cirrus Macular Thickness Multiple Sclerosis Multiple Sclerosis
C15438 Imaging change in normal appearing white matter value

Change in tissue integrity in normal-appearing white matter as compared to a reference scan acquired at an earlier timepoint

Exploratory Imaging Analysis Results - Follow Up Multiple Sclerosis Multiple Sclerosis
C57041 Fatigue diary fatigue level value

Value of the level of fatigue an individual has entered within the Fatigue Diary

Exploratory Fatigue/Activity Record and Diary Multiple Sclerosis Multiple Sclerosis
C15336 Optical coherence tomography (OCT) time-domain performed indicator

The indicator for whether the time-domain optical coherence tomography (OCT) (Stratus - Zeiss) was performed.

Exploratory Imaging Optical Coherence Tomography (OCT) Information Multiple Sclerosis Multiple Sclerosis
C10855 Grip strength maximum measurement

Measurement of the maximum grip strength attained in the trial being recorded

Exploratory Grip Strength Fatigue Multiple Sclerosis Multiple Sclerosis
C15418 Imaging gray matter volume fraction value

Volume of gray matter in the brain or ratio of gray matter volume to total intracranial volume or other head-size normalization volume

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C19006 Imaging brain measured structure other text

The free-text field related to 'Imaging brain measured structure type' specifying other text. The structure of the brain volume measurement

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15462 Imaging spinal cord volume value

Volume of the spinal cord

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
C15343 Optical coherence tomography (OCT) total macular volume abnormal status

This variable indicates whether the macular volume is abnormally low based on optical coherence tomography (OCT).

Exploratory Imaging OCT Analysis - Stratus Retinal Thickness Report Multiple Sclerosis Multiple Sclerosis
C15491 Imaging brain measured structure type

The structure of the brain volume measurement

Exploratory Imaging Analysis Technique and Results - Baseline Multiple Sclerosis Multiple Sclerosis
Displaying 26 - 50 of 1733

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.