F1058-C10959
C10959
Spectroscopy spectral bandwidth value
Spectral bandwidth, in Hertz per pixel, used for both metabolite and water signal reference data acquisitions
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C18708
C18708
Imaging pulse sequence type other text
The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C12509
C12509
Imaging radio frequency coil category
Type of radio frequency (RF) coil(s) category used for the body part scanned
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17940
C17940
Spectroscopy geometry voxel slice size anterior posterior value
Value, in mm, of voxel or slice anterior-posterior size for the spectroscopy scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17949
C17949
Spectroscopy water reference data acquire averages count
Count of averages of water reference data, if any, acquired
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C08238
C08238
Imaging repetition gap duration
Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10938
C10938
Imaging STEAM mixing duration
Duration, in ms, of the STEAM mixing time (TM) as a spectroscopic sequence parameter in the scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10960
C10960
Spectroscopy PRESS symmetry type
Whether the echo time (TE) used in the PRESS (double spin-echo) sequence is symmetrically or asymmetrically divided
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C18714
C18714
Imaging radio frequency coil channel count other text
The free-text field related to 'Imaging radio frequency coil channel count', specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C12510
C12510
Imaging post-processing residual water signal filter name
Name of the residual water signal removal filter, if any, used in post processing
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17941
C17941
Spectroscopy geometry voxel slice size inferior superior value
Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17950
C17950
Spectroscopy water signal suppression bandwidth indicator
Indicator related to bandwidth of water suppression of the spectroscopy scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C08239
C08239
Imaging echo duration
Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10942
C10942
Imaging voxel anatomic site
The anatomic site in which the voxel is located (e.g., brain left frontal white matter)
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10963
C10963
Imaging B0-susceptibility distortion correction indicator
Indicator as to whether image post-processing has included co-registering to T2-weighted image(s) for B0-susceptibility distortion correction
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C18716
C18716
Imaging scanner manufacturer name other text
The free-text field related to 'Imaging scanner manufacturer name', specifying other text. Name of manufacturer of imaging scanner
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C12511
C12511
Imaging post-processing raw data save indicator
Indicator of whether raw data was saved in post processing
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17942
C17942
Spectroscopy sequence parameter PRESS asymmetry TE1 value
Value, in ms, of echo time (TE) 1 for an asymmetric PRESS sequence if used in the scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17951
C17951
Spectroscopy sequence other type text
Text specification of unlisted spectroscopy sequences used in the scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C08241
C08241
Imaging field of view axis 1 measurement
Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10945
C10945
Imaging voxel volume measurement
Volume of the voxel calculated by multiplying the three size measurements
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C10964
C10964
Imaging eddy current induced spectral distortion correction indicator
Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation)
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C18718
C18718
Imaging scanner strength value type other text
The free-text field related to 'Imaging scanner strength value type', specifying other text. Type of value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C12542
C12542
Imaging nuclei type
The type as related to nuclei in the scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)
F1058-C17943
C17943
Spectroscopy geometry matrix in-plane size value
Value of the in-plane matrix size, if applicable for the spectroscopy scan being reported
Supplemental
Magnetic Resonance Spectroscopy (MRS)
False
Duchenne Muscular Dystrophy/Becker Muscular Dystrophy
Duchenne Muscular Dystrophy (DMD)/Becker Muscular Dystrophy (BMD)