CDE Catalog

***Please contact the NINDS CDE Team (NINDSCDE@emmes.com) if you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport-Related Concussion (SRC) or Traumatic Brain Injury (TBI) as the Disease, please select a Subdisease as well.

NeuroRehab Comprehensive includes all NeuroRehab CDE recommendations. NeuroRehab General includes all NeuroRehab CDE recommendations that are not disease specific. All other NeuroRehab Subdiseases include recommendations specific to existing NINDS CDE project disorders.

Choose your Time Frame for your SRC study (Acute (time of injury until 72 hours), Subacute (after 72 hours to 3 months), and Persistent/Chronic (3 months and greater post-concussion) or Comprehensive if your study falls across the study time frames.

Choose your type of TBI study (Acute Hospitalized, Concussion/Mild TBI, Moderate/Severe TBI: Rehabilitation, or Epidemiology) or Comprehensive if your study falls outside of the study types or incorporates aspects of more than one type of study.

Search Form

Displaying 251 - 275 of 1051
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Subdisease Name
C12713 Electrophysiology blink reflex test ipsilateral R2 latency value

Duration of ipsilateral R2 latency in the blink reflex test

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12714 Electrophysiology blink reflex test contralateral R2 latency value

Duration of contralateral R2 latency in the blink reflex test

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12715 Electrophysiology repetitive nerve stimulation study stimulation rate value

Value, in Hz, of the stimulation rate used in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12716 Electrophysiology repetitive nerve stimulation study stimulus duration

Duration, in ?s, of stimulation in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12717 Electrophysiology repetitive nerve stimulation study stimulus intensity value

Value, in mV, of stimulation intensity in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12718 Electrophysiology repetitive nerve stimulation study preactivation number

The numeric identifier corresponding to the amplitude and area values recorded for preactivation during the repetitive nerve stimulation study

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12719 Electrophysiology repetitive nerve stimulation study preactivation amplitude measurement

Measurement, in mV, of the amplitude of the preactivation being described for the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12720 Electrophysiology repetitive nerve stimulation study preactivation area measurement

Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12721 Electrophysiology repetitive nerve activation technique type

Indicator of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12722 Electrophysiology repetitive nerve high frequency

Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12723 Electrophysiology repetitive nerve activation duration

Duration, in sec, of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12724 Electrophysiology repetitive nerve postactivation elapsed time duration

Interval, in minutes, elapsed after nerve stimulation, at which time postactivation data are being recorded for the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12725 Electrophysiology repetitive nerve postactivation number

The numeric value given to the amplitude and area values recorded for postactivation during the repetitive nerve stimulation study

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12726 Electrophysiology repetitive nerve postactivation amplitude measurement

Measurement, in mV, of the amplitude of the postactivation being described at the time specified for the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12727 Electrophysiology repetitive nerve postactivation area measurement

Measurement, in mVms, of the area of the postactivation being described at the time specified for the repetitive nerve study being recorded

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12728 Needle electromyography electrode type

Type of electrode used for the needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12729 Needle electromyography spontaneous activity type

The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12730 Needle electromyography motor unit action potential amplitude measurement

The amplitude value of the motor unit action potential (MUAP) measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12731 Needle electromyography motor unit action potential area measurement

The area value of the motor unit action potential (MUAP) measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12732 Needle electromyography motor unit action potential duration

The duration of the motor unit action potential during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12733 Needle electromyography motor unit action potential complexity percent value

The complexity of the motor unit action potential measured during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12734 Needle electromyography motor unit action potential stable indicator

The stability of the action potential measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12735 Needle electromyography motor unit action potential recruitment type

The recruitment of the motor unit action potential measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12736 Needle electromyography motor unit action potential activation type

The activation of the motor unit action potential measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
C12737 Needle electromyography interference pattern analysis technique name

The interference pattern technique used for analysis measure during needle electromyography

Supplemental Electrophysiology Congenital Muscular Dystrophy Congenital Muscular Dystrophy (CMD)
Displaying 251 - 275 of 1051

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.